• Title/Summary/Keyword: 장치위치

Search Result 2,752, Processing Time 0.029 seconds

Study on the Integration of MMS and Airborn Survey Data for the Implementation of Precise Road Spatial Database (정밀도로공간정보 구축을 위한 지상 MMS 측정자료와 항공측량자료의 결합방법 연구)

  • Hwang, Jin Sang;Kim, Jae Koo;Yun, Hong Sik;Jung, Woon Chul
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.97-104
    • /
    • 2015
  • Due to the introduction of various IT devices, including the recently smartphones and the widespread use of the car navigation system to the location-based information service space has been increased. Spatial information users have been requiring higher levels of quality. In this paper, we study how to build accurate three-dimensional space information by integrating MMS(Moblie Mapping System) survey and airborne survey data. Thus, to analyze the tendency of deviation between the MMS survey and airborne survey data observed in the experimental region, the deviation tendency of the data, it was confirmed that was not consistent. Deviation correction model to select how to change the georeferencing information directly contained in the GPS/INS processing results for the determination, classifies the standard is a method for acquiring the correction reference point coordinates using the calibration model, and analyzed their advantages and disadvantages. With the information of the reference point obtained by airborne photograph of a project, using the method of correcting the MMS survey data. Not only clear the deviation existing between the MMS survey data, it was possible to confirm that the deviation exists between the airborne survey data and MMS survey data was also almost erased.

Implant supported removable dental prosthesis with magnetic attachment in crossed occlusion: A case report (엇갈린 교합에서 implant와 magnetic attachment를 이용한 국소의치 증례)

  • Lee, Yu Jin;Lee, Richard sungbok;Lee, Suk Won;Park, Su Jung;Ahn, Su Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.53-60
    • /
    • 2017
  • When attempting to restore the oral function of a partially edentulous patient, there are a number of prosthetic treatment options available, depending on the structure of remaining teeth. For example, when only one set of maxillary and mandibular teeth are diagonally in place across from each other, it is difficult to gain stable occlusion. In this case, implants can be put in place at the corresponding edentulous area to achieve balance. By doing so, a stable occlusion can be achieved. For this case report, a patient with crossed occlusion after extraction was treated with maxillary RDP (removable dental prosthesis) and mandibular implant-supported RDP (removable dental prosthesis). Moreover, an implant fixture was placed under the posterior molar of the distal extension base diagonally across from the remaining maxillary teeth. Then, magnetic attachment was implemented. According to the patient who received the treatment, the result was functionally and aesthetically satisfactory.

CONSERVATIVE TREATMENT OF A UPPER CENTRAL INCISOR WITH POOR PROGNOSIS (예후가 불량한 상악 중절치의 유지)

  • Lee, Doo-Young;Kim, Seung-Hye;Choi, Hyung-Jun;Choi, Byung-Jai;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.368-373
    • /
    • 2010
  • The incisors function as instruments for biting and cutting food during mastication. They also support the lips and face and maintain vertical dimension. In addition, they contribute to overall normal arch appearance. They play important role during the articulation of speech and assist in guiding jaw closure. Extraction and space maintenance are the most common treatment for a tooth with poor prognosis. However, in the mixed dentition, extraction of the upper permanent incisors results in many complications, such as resorption of alveolar bone, poor esthetics, pronunciation, and mastication. Considering these various roles of incisors in oral cavity, approach for traumatized incisors, even the ones with poor prognosis, should be considered first prior to simple extraction. The dentist must take into account the age of the patient, growth potential, occlusion, oral hygiene status, economic status and motivation towards dental health in addition to patient compliance. In this case, although the prognosis was predicted to be unfavorable due to short root and mobility, we could save the central incisor using conservative treatment, reposition by orthodontic appliance instead of extraction.

Evaluation of Stability of Double Threaded Implant-Emphasis on Initial Stability Using Osstell MentorTM; Part I (이중나사산 임플란트의 안정성에 대한 평가 - 오스텔 멘토를 이용한 초기 안정성 ; PART I)

  • Kim, Si-Yeob;Kim, Byung-Kook;Heo, Jin-Ho;Lee, Ju-Youn;Jeong, Chang-Mo;Kim, Yong-Deok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.4
    • /
    • pp.327-336
    • /
    • 2007
  • Purpose This study was planned to compare and evaluate the stability of implant using $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Material and methods Artificial bone and RBM(resorbable blasting media) surface blasted implants(Osstem US II, SS II implants - diameter: 4mm, length: 13mm) were used. To measure the stability of installed implants, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ were used. In the first experiment, five implants were installed in D1(external type implants) and D3(internal type implants). In the second experiment, 4 internal type implants were divided in two groups and installed in D1 artificial bone with different depth. In the third experiment, two external implants were installed in D1 and D3 artificial bone each and two internal implants were installed in D1 and D3 artificial bone. In all groups, their stability were measured by $Osstell^{TM}$ and Osstell $Mentor^{TM}$. Results In all groups, $Osstell^{TM}$ and Osstell $Mentor^{TM}$ both showed reliable measurement values. The value difference between $Osstell^{TM}$ and Osstell $Mentor^{TM}$ was observed but the difference was small and clinically acceptable. Conclusion These results suggest that the use of Osstell $Mentor^{TM}$ has clinical relevance in the assessment of implant stability.

3-dimensional finite element analysis of maxillary molar distalization using R-jig with TADs (TADs와 R-jig를 이용한 상악 구치 원심 이동에 관한 3차원 유한요소 분석)

  • Tark, Myung-Hyun;Lee, Keunyoung;Cho, Jin-Woo;Chee, Young-Deok;Cho, Jin-Hyoung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.4
    • /
    • pp.265-277
    • /
    • 2014
  • Purpose: The purpose of this study was to investigate the differences of displacement pattern depending on type of sliding jig and application method during maxillary molar distalization with temporary anchorage devices (TADs). Materials and Methods: Maxilla with normal tooth size and arch shape was selected to create a 3-dimensional finite element model, which included the bracket, orthodontic main archwire, removable sliding jig (R-jig). The orthodontic mini-implant anchorage was set 8 mm superiorly from main archwire, buccally between the second premolar and first molar. The base experimental design was Condition 1, which was composed $0.019{\times}0.025$ inch stainless steel (SS) of wire size of R-jig, 200 gm force, un-tied state. And the other designs varied to wire size of R-jig, magnitude of force. The results are as follows. Results: As the wire size of R-jig was increased, the deformation of R-jig was decreased. However, the displacement of second molar wasn't different each other. As the force to second molar was increased, the more displacement of second molar was observed, and the more distal tipping movement, vetical displacement was observed. Conclusion: R-jig can get distal teeth movement in orthodontic treatment without side effects.

Surface Deformation and Behavior of Magma Activity Using EDM (EDM을 활용한 지표변화율과 마그마 활동 양상 변화 연구)

  • Yun, Sung-Hyo;Lee, Jeong-Hyun
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.71-81
    • /
    • 2013
  • Measuring the distance between benchmarks placed on a volcano tens to thousands of meters apart can sometimes pinpoint where and when magma is rising toward the surface. Rising magma will sometimes push overlying rocks upward or shove them aside. In either case, one part of the volcano may actually move horizontally relative to another part from as little as a few millimeters to as much as several tens of meters. The challenge in measuring such changes with an electronic distance meter is putting benchmarks in the right places and making frequent measurements between pairs of benchmarks. An electronic distance meter is an instrument that both sends and receives an electromagnetic signal. Depending on the distance between the EDM and reflector, the wavelength of the returned signal will be out of phase with the transmitted signal. The instrument compares the phase of the transmitted and received signals and measures the phase difference electronically. There is a wide range of EDM capabilities in range and precision, but for volcano monitoring purposes, short-range (less than 10 km) to medium-range (less than 50 km) EDM's are typically used. Short-range EDM's transmit and receive the near visible infrared part of the electromagnetic spectrum for measuring distances with an accuracy of about 5 mm.

Development of Composite Sensing Technology Using Internet of Things (IoT) for LID Facility Management (LID 시설 관리를 위한 사물인터넷(IoT) 활용 복합 센싱 적용기술 개발)

  • Lee, Seungjae;Jeon, Minsu;Lee, Jungmin;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.22 no.4
    • /
    • pp.312-320
    • /
    • 2020
  • Various LIDs with natural water circulation function are applied to reduce urban environmental problems and environmental impact of development projects. However, excessive Infiltration and evaporation of LID facilities dry the LID internal soil, thus reducing plant and microbial activity and reducing environmental re duction ability. The purpose of this study was to develop a real-time measurement system with complex sensors to derive the management plan of LID facilities. The test of measurable sensors and Internet of Things (IoT) application was conducted in artificial wetlands shaped in acrylic boxes. The applied sensors were intended to be built at a low cost considering the distributed LID and were based on Arduino and Raspberry Pi, which are relatively inexpensive and commercialized. In addition, the goal was to develop complex sensor measurements to analyze the current state o f LID facilities and the effects of maintenance and abnormal weather conditions. Sensors are required to measure wind direction, wind speed, rainfall, carbon dioxide, Micro-dust, temperature and humidity, acidity, and location information in real time. Data collection devices, storage server programs, and operation programs for PC and mobile devices were developed to collect, transmit and check the results of measured data from applied sensors. The measurements obtained through each sensor are passed through the Wifi module to the management server and stored on the database server in real time. Analysis of the four-month measurement result values conducted in this study confirmed the stability and applicability of ICT technology application to LID facilities. Real-time measured values are found to be able to utilize big data to evaluate the functions of LID facilities and derive maintenance measures.

Visual Feedback System for Manipulating Objects Using Hand Motions in Virtual Reality Environment (가상 환경에서의 손동작을 사용한 물체 조작에 대한 시각적 피드백 시스템)

  • Seo, Woong;Kwon, Sangmo;Ihm, Insung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.26 no.3
    • /
    • pp.9-19
    • /
    • 2020
  • With the recent development of various kinds of virtual reality devices, there has been an active research effort to increase the sense of reality by recognizing the physical behavior of users rather than by classical user input methods. Among such devices, the Leap Motion controller recognizes the user's hand gestures and can realistically trace the user's hand in a virtual reality environment. However, manipulating an object in virtual reality using a recognized user's hand often causes the hand to pass through the object, which should not occur in the real world. This study presents a way to build a visual feedback system for enhancing the user's sense of interaction between hands and objects in virtual reality. In virtual reality, the user's hands are examined precisely by using a ray tracing method to see if the virtual object collides with the user's hand, and when any collision occurs, visual feedback is given through the process of reconstructing the user's hand by moving the position of the end of the user's fingers that enter the object through sign distance field and reverse mechanics. This enables realistic interaction in virtual reality in real time.

Detection of Fracture Signals of Low Prestressed Steel Wires in a 10 m PSC Beam by Continuous Acoustic Monitoring Techniques (연속음향감지기법을 이용한 긴장력이 감소된 10 m PSC보의 PS 강선 파단음파 감지)

  • Youn, Seok-Goo;Lee, Chang-No
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.113-122
    • /
    • 2010
  • Corrosion of prestressing tendons and wire fractures in grouted post-tensioned prestressed concrete bridges have been considered as a serious safety problem. In bridge evaluation the condition of prestressing tendons should be inspected, and if corroded tendons are found, the loss of tendon area should be included when we calculate the ultimate strength. In the previous study, it was evaluated that continuous acoustic monitoring techniques could be considered as a reliable non-destructive method for detecting wire fractures of fully grouted post-tensioned prestressing tendons. In the present study, an experimental test was performed for detecting wire fractures of post-tensioned prestressing tendons which are prestressed lower than current design level. A 10 m prestressed concrete beam was fabricated, which included two tendons prestressed 66 percentage and 40 percentage of tensile strength, respectively. The corrosion of two tendons was induced by an accelerated corrosion equipment and the test beam was monitored by using seven acoustic sensors and a continuous acoustic monitoring system. From each prestressing tendon, two acoustic signals of wire fractures were successfully detected and source locations were estimated within 20 mm error. Based on the test results, it is considered that continuous acoustic monitoring techniques can be applied to detect low-prestressed wire fracture in fully grouted post-tensioned prestressed concrete beams.

A study on treatment effects of Class III cases by second molar extraction (제 2 대구치 발거에 의한 III급 부정교합자의 치료효과에 관한 연구)

  • Lee, Sung-Hee;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.34 no.2 s.103
    • /
    • pp.109-119
    • /
    • 2004
  • This study aimed at investigating the skeletal, dentoalveolar, and soft tissue changes of Class III malocclusion cases treated by second molar extraction. The lateral cephalograms of 15 subjects with moderate Class III malocclusion by average ANB $-1.4^{\circ}\;and\;IMPA\;85^{\circ}$ were traced and the computerized superimposition of average craniofacial change was made. The data was gathered and statistically analyzed. The results were as follows: 1 Lower anterior facial height/anterior facial height increased by 0.6%(P<0.01), mandibular plane increased by $1.5^{\circ}$(P<0.05). 2. There was a slightly downward & backward rotation of the mandible. 3. Lower first molar tipped distally by 4.nm(P<0.001), lower anterior teeth lingually tipped by $3.2^{\circ}$(P<0.05). 4. Retracted lower lip improved facial profile. This study may suggest that second molar extraction could be effective for a moderate Class III malocclusion to make distalization of the lower first molar easier and avoid severe lingual tipping of the lower incisor, if the lower third molar has a normal shape, good direction of eruption and adequate time for lower second molar extraction