• Title/Summary/Keyword: 장기운전

Search Result 224, Processing Time 0.028 seconds

Efficient Sewage Treatment with Less sludge Production by Used Briquets (연탄재를 이용한 슬러지 저감 하수처리 연구)

  • Jeong, Doo-Young;Jeong, Myung-Hee;Song, Dae-Yong;Kim, Young-Jun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.16 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • We have investigated the efficacy and efficiency of the used briquets for the sewage treatment in this study. The effluent of wastewater treated by Used Briquets Process (UBP) showed very low values of $BOD_5$, CODcr, and SS (1.1 mg/L, 9.5 mg/L, and 3.8mg/L, respectively), which corresponded to 99%, 92.7%, and 96.3% of removal efficiency to the raw wastewater. The number of total bacteria and E. coli in the effluent water treated by UBP was found to be 9 and 1.2 cfu/ml, respectively, showing the remarkable decrease in number, when compared to that of other sewage treatment plants. In the long period of experiment over 1 year, UBP has also shown the high removal efficiency with less sludge production, and low seasonal fluctuation of the values. This UBP is very environmentally-friendly process in the aspects of recycling used briquets and reducing the sludge production. We think that this process will be useful for both the small-scale sewage treatment and reuse of the effluent water.

  • PDF

The Optimization of Cylindrical Perforated Burner for Condensing Gas Boiler (콘덴싱 가스보일러용 원통형 다공버너의 최적화 연구)

  • 이창언;장기현;이강주;정영식
    • Journal of Energy Engineering
    • /
    • v.11 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • The objective of performing this study is to develop low emission condensing gas boiler. To reduce NOx and CO, three reasonable distances between burner and heat exchanger were decided through the experiments of model plane burner. Three burners with different diameter were made and then emission characteristics were examined. The optimum burner geometry was determined from flame stability, pollutant emission characteristics and applicability to the practical boiler system. In the domain of equivalence ratio 0.68~0.85, turn-down ratio of the burner designed by this research was extended to a wider range of 5 : 1. Thermal efficiency of the boiler developed by this study reached to 97% (LHV basis) of heating water efficiency at heating load of 20,000 kcal/hr when fueled by both of LNG or LPG. Emission ($O_2$=0%, wet basis) of NOx and CO concentration was 26 ppm and 85 ppm when fueled by LNG, 41 ppm and 113 ppm when fueled by LPG respectively.

Sludge Disposal Analysis of Sanitary Paper Manufacturing Wastewater Treatment Plant (위생용지 생산 제지공장 폐수슬러지의 처리 현황)

  • Jung, Yong-Jun;Lee, Hong-Tae
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.471-476
    • /
    • 2013
  • The operating conditions of sludge disposal for sanitary paper manufacturing wastewater treatment plant were monitored on the basis of daily check sheets during the 3 years of operation. Generated wastes were mainly composed of 79% of sludge, 14% of ash, 5% of waste synthetic resin and 2% of etc. Maximum sludge was produced to 233 ton and the average was 113 ton daily, where the primary sludge occupied 85% and 15% for the secondary sludge. The concentration of coagulant for sludge dewatering was extremely exceeded and the additional experiment such as jar-test was required for the establishment of proper dosage. Presently, the generated sludges were partially treated outside and were also partly handled inside. In the future, most sludges will be expected to be treated to recycling material for the iron industry.

Characteristic Evaluation of Industrial Radiant Tube Burner System with Oscillating Combustion Technology - NOx Reduction and Performance Improvement - (맥동연소기술을 적용한 산업용 복사관 버너시스템의 특성 평가 - NOx 저감 및 성능 향상 -)

  • Oh, Hyuk-Jin;Cho, Han-Chang;Cho, Kil-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.5
    • /
    • pp.539-545
    • /
    • 2011
  • Combustion characteristics of industrial radiant tube (RT) burners with forced oscillating combustion technology are investigated using a real-scale (125,000 kcal/h) industrial RT burner facility in both laboratory and field tests. Three different types of industrial RT burners using a by-product gas from the iron-and-steelmaking process are examined in a laboratory facility equipped with a W-type RT. During the field tests, an industrial RT burner is characterized in a large facility equipped with multiple RTs. Their performance and emission controls are investigated under diverse operating conditions. The feasibility of the forced oscillating combustion technology is evaluated by the extent of $NO_x$ reduction and the efficiency improvement. These improvements are able to save energy, extend the RT lifetime, and enhance productivity. The operating conditions that achieve the best performance and emission control for each RT burner are determined.

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 모사)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

A Simulation Study on the Annual Heating Performance of the Seawater-Source Screw Heat Pump (해수열원 스크류 히트펌프의 연간 난방운전 성능 시뮬레이션)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Kang, Byung-Chan;Ra, Ho-Sang;Kim, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.488-493
    • /
    • 2012
  • In this study, in order to utilize the seawater as a heat source at Gangneung city near the East Sea in Korea, an annual heating performance of a screw heat pump was simulated. For a simulation, the maximum heating capacity of heat pump was assumed at 3.5 MW. An ambient temperature at Gangneung city was calculated from the TMY2 weather data, while the seawater temperature was calculated from the regression equation based on the measurement by the National Fisheries Research and Development Institute of Korea. The heating load was assumed linearly dependent on the ambient temperature, while the maximum heating load was assumed to appear when the ambient temperature is below $-2.4^{\circ}C$, which is the temperature of TAC 2.5% for heating at Gangneung city. A heat pump performance at full-load was calculated from the regression equation, which involves refrigerant's evaporating and condensing temperatures, based on a commercial screw compressor performance map. A heating supply temperature which determines refrigerant's condensing temperature was assumed linearly dependent on the heating load. A performance degradation due to the part-load operation of heat pump was also considered. Simulation results show that an annual heating coefficient of performance ($COP_H$) of a seawater-source screw heat pump is approximately 2.8 and that it is necessary to improve part-load performance to increase an annual performance of the heat pump.

  • PDF

Experimental Study on the Cooling and Heating Operation Characteristics of a Sea Water Source Heat Pump (해수열원 히트펌프 시스템의 냉난방 운전 특성에 관한 실증 연구)

  • Kim, Ji-Young;Baik, Young-Jin;Chang, Ki-Chang;Ra, Ho-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.544-549
    • /
    • 2009
  • The purpose of this study is to investigate the field Operation Characteristics of a sea water heat source cascade heat pump system and system applicable to Building. Cascade heat pump system is composed R410A compressor, R134a compressor, EEV, cascade heat exchanger, Plate heat exchanger etc. Building area is $890m^2$ and has five floors above ground. R410A is used for a low-stage working fluid while R134a is for a high-stage. The system could runs at dual mode. One is mode of general R410A refrigeration cycle in summer and the other is cascade cycle. In order to gain a high temperature supply water in winter season, the system is designed to perform a cascade cycle. The filed test results show that the sea water heat source heat pump system exhibits a COP of about 5.5 in cooling mode along with a heating COP of about 4.0 in 1-stage heating mode. Cascade 2-stage heat pump system is enough to supply $60^{\circ}C$ water and heating COP is about 3.0

  • PDF

Bacterial Degradation of Monoethanolamine (생물학적 방법에 의한 Monoethanolamine의 분해 연구)

  • Hyun, Jun-Taek;Rhee, In-Hyoung;Kwon, Sung-Hyun;Kim, Dong-Jin;Cho, Dae-Chul
    • KSBB Journal
    • /
    • v.22 no.3
    • /
    • pp.157-161
    • /
    • 2007
  • This study is to investigate the biological degradation and the characteristics of MEA, a pH regulator to be put in the cooling water circulation system for power plants, loading to elevate concentrations of COD and N when eluted into the water environment. MEA, $NH_4^+$ and CODcr were monitored in flask cultures and in a batch aerator. MEA was found to be biologically degradable, producing substantial amount of ammonia (max. 78.1%) in a form of $NH_4^+$ and other carboneous intermediates. The degradation reaction rates were similar one another over all MEA concentrations tested as the activated sludge (microbial consortium) was acclimated to MEA with the gradual and stepwise increase in MEA input into the batch aerator. Also, MLVSS kept increasing with increasing MEA input. The COD-based degradation reaction order was determined to be 1.

Efficient bio-gas desulfurization purification technology development Using ion-exchange fibers (이온교환섬유를 이용한 바이오가스 고효율 탈황정제기술 개발)

  • Tak, Bong-Yeol;Tak, Bong-Sik;Min, Gil-Ho;Lee, Sang-Min;Lee, Won-Gu;Lee, So-A
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.116-116
    • /
    • 2011
  • 바이오 가스 플랜트의 혐기소화 공정에서 발생하는 바이오 가스는 중 유해가스인 황하수소($H_2S$)는 부식성 가스로 수천 PPM농도를 함유하여, 발전기나 가스보일러로 이용하는 경우에는 $H_2S$를 제거하는 탈황공정이 반드시 필요하다. 탈황방식에는 산화철 탈황(건식 탈황)과 생물 탈황이 현재 많이 사용되고 있어나 산화철 탈황은 산화철 pellet이 유화철에 변화하면 탈황능력이 저하되어 pellet을 교환해야 하며 많은 비용이 발생한다. 생물 탈황 방식은 유황산화세균의 서식활동조건(온도, 반응시간, 산소량)확보가 반드시 필요하여 높은 운전기술을 필요로 한다. 본 연구에서는 바이오가스 전처리 기술 중 활성탄 또는 약액을 이용한 기존의 탈황정제방식보다 흡착성능이 뛰어난 이온교환섬유를 이용하여, 황화수소($H_2S$)를 95% 이상 제거할 수 있는 고효율 섬유상 이온촉매 악취제거 시스템 개발을 수행하였다. 이온교환섬유는 방사선 조사를 이용하여 부직포에 라디칼을 인위적으로 형성시켜(그라프트 중합) 양이온 또는 양이온을 교환할 수 있도록 제조된 섬유상의 흡착제로, 이온교환 섬유의 화학적 이온교환과 물리적 흡착 및 탈착반응이 동시에 발생되고, 활성탄/실리카켈 보다 흡착능력이 2~4배 높다. 또한 이온섬유의 재생기능을 이용하여 장기적 다양한 악취($H_2S$, $NH_3$, 아민계, 메르갑탄류, 알데히드 등) 및 유해가스(VOCs, NOx, SOx) 등을 95% 이상 제거할 수 있다.

  • PDF

허리통증유발 탈출 수핵의 대용량제거를 위한 플라즈마발생 전극개발에 관한 연구

  • Yun, Seong-Yeong;Jang, Yun-Chang;Kim, Gon-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.241-241
    • /
    • 2011
  • 최근들어 저온플라즈마를 이용한 생물학적 응용분야가 각광을 받고 있다. 특히 전기전도도를 가진 전해질 내에서 형성된 액상 플라즈마는 열손상없이 암, 세균 및 비정상 장기조직의 제거가 가능하다는 점에서 기존 시술들이 가지는 문제를 해결할 수 있다. 허리통증을 유발하는 탈출 수핵을 대용량으로 제거하기위한 플라즈마발생 전극에 관한 연구가 수행되었다. 수핵 분해량을 늘리기 위해서는 플라즈마를 통하여 다량의 수산화기 라디컬을 형성, 수핵표면에 조사해야 한다. 이를 위하여 6개의 텅스텐 전극표면에서 기포를 발생시켜 플라즈마 발생면적을 넓힐 수 있었다. 텅스텐 전극들은 캡톤코딩과 세라믹 스페이서를 통하여 분리되었고, 전극의 후방에는 SUS 재질의 환형 접지전극을 배치하여 6개의 텅스텐 전극표면에서 모두 기포가 발생할 수 있도록 하였다. 시술적용시 플라즈마 및 전극이 가지는 제한 조건은 단백질 변성을 막기위한 섭씨 45도 이하의 온도 상승과 조직에 대한 기계적인 손상 방지를 위한 2.5 mm 이하의 전체 전극 굵기이다. 이를 만족하는 가운데 수산화기 라디컬 형성을 증대할 수 있는 전극의 구조를 결정하기 위하여 1-D 전기 열유체 모델 도입하였다. 모델에서 도출된 기포의 두께를 바탕으로 다중전극간의 거리 조절을 통하여 플라즈마 방전구조를 전극 - 전극 (기포두께${\times}2$ > 전극간 거리)과 전극 - 기포표면 (기포두께${\times}2$ < 전극간 거리)으로 통제하였다. 형성된 플라즈마의 소모전력, 전자 밀도및 수산화기 라디컬의 회전온도를 분석하기 위하여 0.9% 염화나트륨 수용액, 1.6 S/m, 전해질에서 플라즈마 형성를 형성하고 전기신호 및 광학신호를 관측하였다. 전극에 인가된 전압은 340 VRMS이며 운전주파수는 380 kHz이다. 실험 결과, 전극 - 기포표면 방전구조는 전극 -전극 방전구조에 비하여 전해질의 저항역할로 인하여 방전전류가 3.4 Ipp에서 1.6 Ipp로 감소하였으나, 기포표면에서의 물분자의 분해로 인하여 수산화기 라디컬에서의 발광세기는 약 4배 증가하였다. 또한 수산화기의 회전온도 분포상에서도 전극 - 기포표면 방전은 주변 물분자의 열교환으로 인하여 전극 -전극간 방전의 1500K 에 비하여 낮은 400K를 보였다. 이는 전극-기포표면 방전구조의 전극이 낮은 온도의 수산화기를 다량으로 형성할 수 있음을 시사하며, 카데바를 이용한 실험에서 220초에 걸쳐 약 87%의 수핵을 기계적 손상 및 단백질 변형없이 효과적으로 제거함을 확인하였다.

  • PDF