• Title/Summary/Keyword: 잔류염소 농도

Search Result 118, Processing Time 0.025 seconds

Persistent Organic Pollutants (POPs) Residues in Greenhouse Soil and Strawberry Organochlorine Pesticides (딸기 시설재배지 토양 및 농산물 중 잔류성유기오염물질(POPs)의 잔류량 - 유기염소계 농약)

  • Lim, Sung-Jin;Oh, Young-Tak;Jo, You-Sung;Ro, Jin-Ho;Choi, Geun-Hyoung;Yang, Ji-Yeon;Park, Byung-Jun
    • Korean Journal of Environmental Agriculture
    • /
    • v.35 no.1
    • /
    • pp.6-14
    • /
    • 2016
  • BACKGROUND: Residual organochlorine pesticides (OCPs) are chemical substances that persist in the environment, bioaccumulate through the food web, and pose a risk of causing adverse effect to human health and the environment. They were designated as persistent organic pollutants (POPs) by Stockholm Convention. Greenhouse strawberry is economic crop in agriculture, and its cultivation area and yield has been increased. Therefore, we tried to investigate the POPs residue in greenhouse soil and strawberry.METHODS AND RESULTS: Extraction and clean-up method for the quantitative analysis of OCPs was developed and validated by gas chromatography (GC) with electron capture detector (ECD). The clean-up method was established using the modified quick, easy, cheap, effective, rugged, and safe(QuEChERS) method for OCPs in soil and strawberry. Limit of quantitation (LOQ) and recovery rates of OCPs in greenhouse soil and strawberry were 0.9-6.0 and 0.6-0.9 μg/kg, 74.4-115.6 and 75.6-88.4%, respectively. The precision was reliable sincerelative standard deviation (RSD) percentage (0.5-3.7 and 2.9-5.2%) was below 20, which was the normal percent value. The residue of OCPs in greenhouse soil was analyzed by the developed method, and dieldrin, β-endosulfan and endosulfan sulfate were detected at 1.6-23, 2.2-28.4 and 1.8-118.6 μg/kg, respectively. Those in strawberry were not detected in all samples.CONCLUSION: Dieldrin, β-endosulfan and endosulfan sulfate in a part of investigated greenhouse soil were detected. But those were not detected in investigated greenhouse strawberry. These results showed that the residue in greenhouse soil were lower level than bioaccumulation occurring.

A Survey for Pesticide Residues in Major Rivers of Korea (주요하천수(主要河川水)에 대(對)한 농약잔류(農藥殘留) 실태조사(實態調査))

  • Lee, Hae-Keun;Lee, Young-Deuk;Park, Young-Sun;Shin, Yong-Hwa
    • Korean Journal of Environmental Agriculture
    • /
    • v.2 no.2
    • /
    • pp.83-89
    • /
    • 1983
  • To obtain basic information for the safe use of pesticides, the aquatic environment of 5 major rivers was surveyed in April and August 1982 for organochlorine and organophosphorus pesticide residues. Regardless of sampling times and sites, pesticide residue levels were very low. Of the organophosphorus pesticides surveyed, only IBP and diazinon were detected in water samples while fenthion, fenitrothion, chlorpyriphos, chlorpyriphos-methyl, chlorfenvinphos, phenthoate, and edifenphos were not detected in any water samples. Residue levels and detection frequencies of IBP or diazinon were much higher in water samples collected in August than those collected in April. Detection frequencies of organochlorine pesticides, on the other hand, were high, but their actual residue levels were very low. BHC was detected nearly in all water samples while aldrin was not found in any samples. Detection frequencies of heptachlor, endosulfan, and o.p`-DDT were considerably high but dieldrin and p.p`-DDT were detected in a few water samples and their residue levels were also very low.

  • PDF

Development and Application of Enzyme Immunoassay for Endosulfan Residue Analysis (Endosulfan 과 그 분해산물의 Enzyme Immunoassay에 의한 분석법의 개발과 응용)

  • Suh, Yong-Tack;Shim, Jae-Han;Lee, Kang-Bong
    • Korean Journal of Environmental Agriculture
    • /
    • v.11 no.1
    • /
    • pp.59-66
    • /
    • 1992
  • An enzyme immunoassay(EIA) was developed for the analysis of insecticide endosulfan and its degradation products. The sensitivity and specificity of the antibody produced were examined. Optimal conditions in the ELISA system for residue analysis were also discussed. A mixed suspension of endosulfan-hemocyanin conjugate(ES-KLH) 1.1 mg/ml and Freund's adjuvant was injected subcutaneously to white rabbits and then collected antisera were tested for titers by indirect ELISA(1/24,000). Because of difficulties in the synthesis of endosulfan peroxidase conjugate, amine derivative of endosulfan-diol was synthesized and it showed 40% of conjugate yields(2mg/ml of conjugate). the highest sensitivity obtained enzyme-conjugate was a concentration of 200ng/ml. The detection limit of endosulfan in ELISA system was 5 ppb on the standard curve. In application of ELISA for residue analysis, the recoveries were really 100% both in the spiked soil and apple sample regardless of endosulfan concentration treated. On the other hand, chlorinated hydrocarbons of similar structure with endosulfan showed low cross-reactivity$(2.2%{\sim}29.2%).$

  • PDF

태화강 주변지역 지하수의 수질특성 및 계절별 수질변화 양상

  • Lee Jong-Seong;Kim Do-Sun;Yun Hye-Jeong;Choi Yeong-A;Choi Yeong-Seon;Im Jong-Seon;Yun Han-Jik;Lee Jin-Yeol;Jeong Su-Geun;Ham Yu-Sik
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2005.04a
    • /
    • pp.441-445
    • /
    • 2005
  • 태화강 주변지역 지하수의 계절적 수질 변화를 보고자 현장측정 항목(수온, pH, 알칼리도, 전기전도도), 일반 항목(증발잔류물, 총경도, 과망간산칼륨소비량), 음이온물질$(F^-,\;Cl^-,\;{NO_3}^-,\;{SO_4}^{2-})$, 양이온물질$(Ca^{2+},\;Mg^{2+},\;K^+,\;Na^+)$등으로 구분하여 분석하였으며, 총 70개 지점을 대상으로 2004년 5월, 10월 2회에 걸쳐 실시하였다. 지역별 수질특성을 살펴보면 남구지역은 $Ca-Mg-HCO_3,\;Ca-Mg-HCO_3-Cl,\;Ca-Mg-Na-Cl-HCO_3,\;Na-Cl-HCO_3$의 4가지 유형이 전체 시료의 74%를 차지하였으며, $Ca-Mg-HCO_3$형이 가장 우세하게 나타났고, 중구지역 지하수에서는 $Ca-Mg-HCO_3-Cl,\;Ca-Mg-Na-HCO_3-Cl,\;Ca-Mg-HCO_3$의 3가지 유형이 전체 시료의 60%를 차지하는 것으로 나타났으며, 이중에서 $Ca-Mg-HCO_3-Cl$형이 가장 우세하게 나타났다. 두 지역의 수질 변화를 살펴보면. 전기전도도는 남구는 $731.5{\mu}s/m^3$에서 $529.8{\mu}s/m^3$, 중구는 $752.6{\mu}s/m^3$에서 $621.6{\mu}s/m^3$로 201.7, $131.0{\mu}s/m^3$만큼 작아져 두 지역 모두 같은 양상을 보였으나, Hardness 및 TDS의 경우 남구지역은 5월보다 10월에 평균, 최대값이 모두 낮게 나타났다. 또한 $Cl^-$의 경우 지역적, 계절적으로 큰 차이를 보이고 있으며 남구는 5월 68.2mg/l, 10월에는 61.7mg/l로 다소 감소하였으나 중구의 경우 5월 75.5mg/l, 10월 122.1mg/l로 다소 증가한 것으로 나타났다. 양이온 분포 비율 및 농도는 비슷하게 나타났으며, 계절적으로 5월보다 10월에 모두 높게 나타났다. 두 지역 모두 양이온물질 중 나트륨의 분포비율 및 농도가 5월보다 10월에 다소 높게 나타났다. 연구 지역 지하수의 계절적 수질변화를 살펴보면 두 지역간의 지하수질 및 분포특성에 있어 다소 차이를 보이고 있으며, 특히 중구 지역에서 5월보다 10월에 나트륨과 염소이온의 증가가 다소 나타나는 것으로 관찰되었다. 또한 연구지역 중 특이지점($Cl^-$:1,000mg/l이상)은 남구는 5월에 2개에서 10월에는 3개 지점으로 증가하였으며, 중구는 5월, 10월 모두 4개 지점으로 나타났다.

  • PDF

Fractionation of DOC and its Correlation to AOX(FP) in the Advanced ater Treatment Process (고도정수처리 공정에서 DOC 분획 특성 및 AOX(FP)와의 관계)

  • Lee, Byung-Cheun;Choi, Kyung-Hee;Choi, Ja-Yoon;Lee, Chul-Hee
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.10
    • /
    • pp.909-918
    • /
    • 2009
  • As a part of dissolved organic matter, dissolved organic carbon (DOC) or biodegradable DOC (BDOC) fraction in particular is one of important issues in water treatment. Due to role as a nutrient source for bacteria, BDOC, therefore, may cause regrowth problems in water distribution system. The main objectives of this study were to investigate the possibility to minimize the concentration of BDOC in advance water treatment process. DOC in water is fractionized into four fractions such as AnBDOC (adsorbable and non-biodegradable DOC) which possesses adsorption properties but no biodegradation ability; nABDOC (biodegradable and non-adsorbable DOC) which has biodegradation properties but no adsorption ability; ABDOC (adsorbable and biodegradable DOC) which has adsorption properties and biodegradable characteristic; and non-removal DOC (nAnBDOC) which do not have either adsorbability or biodegradability. BAC process was effective for adsorbable DOC (AnBDOC+ABDOC) removal. However, in some cases, the removal ratio of adsorbable DOC was not sufficient. BDOC removal rate is very low or irremovable. Thus, for the control of residual DOC, it is necessary to change the operation condition by BAC process. From the analysis results of DOC fractions, water treatment processes appeared to be effective because it could grasp a remarkable amount of biodegradable, adsorbable and non-removal DOC. The concentration of AOX in non-prechlorination process was reduced from 7.1 ${\mu}g$/L to 0.51 ${\mu}g$/L in BAC process followed by ozonation.

Effect of AlF3 on Zr Electrorefining Process in Chloride-Fluoride Mixed Salts for the Treatment of Cladding Hull Wastes (폐 피복관 처리를 위한 염소계-불소계 혼합용융염 내 지르코늄 전해정련공정에서 삼불화알루미늄의 효과 연구)

  • Lee, Chang Hwa;Kang, Deok Yoon;Lee, Sung-Jai;Lee, Jong-Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.2
    • /
    • pp.127-137
    • /
    • 2019
  • Zr electrorefining is demonstrated herein using Zirlo tubes in a chloride-fluoride mixed molten salt in the presence of $AlF_3$. Cyclic voltammetry reveals a monotonic shift in the onset of metal reduction kinetics towards positive potential and an increase in intensity of the additional peaks associated with Zr-Al alloy formation with increasing $AlF_3$ concentration. Unlike the galvanostatic deposition mode, a radial plate-type Zr growth is evident at the top surface of the salt during Zr electrorefining at a constant potential of -1.2 V. The diameter of the plate-type Zr deposit gradually increases with increasing $AlF_3$ concentration. Scanning electron microscopy-energy-dispersive X-ray spectroscopy (SEM-EDX) and X-ray photoelectron spectroscopy (XPS) analyses for the plate-type Zr deposit show that trace amount of Al is incorporated as Zr-Al alloys with different chemical compositions between the top and bottom surface of the deposit. Addition of $AlF_3$ is effective in lowering the residual salt content in the deposit and in improving the current efficiency for Zr recovery.

Application of Electrochemical Technology for Reusing Biologically Treated Water (생물학적 처리수 재이용을 위한 전기화학 기술의 적용)

  • Kang, Gu-Young
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.4
    • /
    • pp.453-458
    • /
    • 2008
  • Laboratory experiments were conducted to investigate disinfection as well as removal of color and residual organics from reclaimed municipal wastewater by electrochemical processes with Nb/Pt anode installed. RNO was rapidly bleached by OH$\cdot$ and the second order rate constants of RNO removal were $\frac{0.223l}{mg{\cdot}min}$, $\frac{1.679l}{mg{\cdot}min}$ and $\frac{2.322l}{mg{\cdot}min}$ with for 5 A, 10 A, and 15 A, respectively, with r$^2$ of > 96%. In batch electrochemical processes, after 15 min at currency of 15 A and initial pH of 5, 7,5 and 9, COD$_{Mn}$ was below 4 mg/L, color unit below 5 degree and general bacteria was not detected, the concentration of which are suitable for drinking water regulation. In the continuous electrochemical process, with HRT of 3.7$\sim$49.2 min, free chlorine were 0.2$\sim$0.7 mg/L, general bacteria was not detected, color unit below 5 degree and THMs was 0.017 mg/L. Therefore, electrochemical process with Nb/Pt anode was employed satisfactory to meet for reusing biologically treated water as well as disinfection.

Concentrations and Distribution Patterns of PCDDs, PCDFs, DL-PCBs, PBDEs in Sediments from Ulsan Bay (울산만 퇴적물 내 PCDDs, PCDFs, DL-PCBs, PBDEs의 잔류수준과 분포패턴)

  • Baek, Seung-Hong;Lee, In-Seok;Choi, Minkyu;Lee, Boo-Han;Hwang, Dong-Woon;Kim, Sook-Yang;Choi, Hee-Gu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.4
    • /
    • pp.186-194
    • /
    • 2013
  • We investigated the concentrations and distribution patterns of 17 polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs), 12 dioxin-like polychlorinated biphenyls(DL-PCBs) and 24 polybrominated diphenyl ethers(PBDEs) in sediments from Ulsan Bay in Korea. The concentrations of PCDD/Fs, DL-PCBs, and PBDEs in 33 sediment samples ranged from 0.11 to 4.86($1.81{\pm}1.04$) pg $WHO_{2005}$-TEQ $g^{-1}$ dry weight(dw), 0.06 to 44.2($4.02{\pm}7.99$) pg $WHO_{2005}$-TEQ $g^{-1}$ dw, and 2.81 to 63.8($19.4{\pm}13.9$) ng $g^{-1}$ dw, respectively. DL-PCBs had dominant contributions(mean, 88%) of total TEQ concentrations in sediment. The concentrations of target compounds in inner locations were higher than those in outer locations in Ulsan Bay (p<0.05). The dominant contribution of highly chlorinated DD/Fs in sediment was associated with combustion process from industrial complexes. Distribution pattern of DL-PCBs was similar with those of commercial PCB products. BDE209 was a dominant congener in sediment, suggesting high use amount of commercial deca-BDE product in surrounding areas.