• Title/Summary/Keyword: 자장

Search Result 779, Processing Time 0.027 seconds

Geographical Distribution of Magnetic Elements Deduced from the Results of the First Order Magnetic Survey in Korea (우리 나라 1등 자기측량 성과를 이용한 자장분포식의 결정에 관한 연구)

  • 최윤수;최경제
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.175-184
    • /
    • 1997
  • In this study, the basic theory of geomagnetism was introduced and the field data of first order magnetic survey was analyzed to determine geographical distribution of magnetic elements such as Declination(D), Inclination(1), Horizontal Component(H), Vertical Component(Z) and Total Force(F). From this distribution equations, the distribution of geomagnetism of Korean peninsula was examined and the declination was calculated for National Base Maps.

  • PDF

Test Results of AC Losses in a High Tc Superconductor (고온 초전도도체의 교류손실 측정 결과)

  • Ryu, Kyung-Woo;Kim, Chang-Wan;Han, Hyung-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.9-11
    • /
    • 2001
  • 현 단계에서도 임계전류밀도가 약 $100A/mm^2$로 충분히 높아 전력분야 응용이 기대되는 Bi-2223테이프에 대한 교류손실을 초전도 전력기기의 실제 상황을 고려하여 측정하였다. 중요한 평가 결과로서는 먼저 통전손실 특성은 외부 교류자장의 세기뿐만 아니라 방향에 따라서도 매우 상이하였으며, 비교적 외부자장이 큰 경우는 동저항손실 메카니즘이, 작은 경우는 그 외의 또 다른 손실 메카니즘이 지배적이었다. 또한 수평자장에 대한 자화손실 특성은 코아 모델로부터 계산된 손실과 비교적 잘 일치하였다. 따라서 자화손실은 히스테리시스 손실 메카니즘이 지배적이라 할 수 있으며, 측정된 자화손실은 저온 초전도체에서는 볼 수 없었던 약한 주파수 의존성을 보였을 뿐만 아니라 외부자장의 세기에 따라서도 주파수 의존 특성이 상이하였다.

  • PDF

Magnetization loss characteristics at arbitrary directional magnetic field by perpendicular magnetization loss in YBCO CC stacked conductors (YBCO CC 적층선재의 수직자화 손실 값을 이용한 임의 방향 자화손실 평가)

  • Lee, Ji-Kwang;Lim, Hyoung-Woo;Cha, Guee-Soo;Park, Myung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.655-656
    • /
    • 2006
  • 대부분의 초전도 전력기기의 경우, 초전도 테이프를 솔레노이드나, 팬케�� 형태로 권선해서 사용하게 되고, 이러한 경우에는 권선을 구성하는 테이프들에 흐르는 전류에 의해 발생하는 자계는 권선내의 각각의 테이프에 임의 방향의 외부 인가자계로 작용하여 자화손실을 발생시키므로 초전도 코일에서의 교류손실을 평가하고 예측하기 위해서는 임의방향 자장에 의한 자화손실에 대한 데이터가 필요하다. 수직 자화손실에 대한 측정값으로서 임의방향 자장에 의한 자화손실을 알 수 있다면 코일의 교류손실 평가는 훨씬 쉽게 접근할 수 있을 것이다. 본 논문에서는 측정된 자화손실 값들로부터 각 방향 인가자장에 의한 자화손실과 인가된 자장을 분리하여 수직방향 및 수평방향 성분에 의한 자화손실 측정값의 합과 비교하여 각도별로 두 자화손실의 차이를 살펴보았다.

  • PDF

Critical current characteristic of solenoid magnet with anisotropic HTS tapes (비등방성을 고려한 고온초전도 솔레노이드 마그네트의 임계 전류 특성)

  • Kang, Joon-Sun;Nah, Wan-Soo;Kwon, Young-Kil;Sohn, Myoung-Hwan;Ryu, Kang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.966-968
    • /
    • 2000
  • 비등방성 고온 초전도 테이프는 자장의 세기뿐만 아니라 방향에 따라서도 임계 전류 값이 영향을 받는다. 이러한 비등방성 고온 초전도 테이프로 권선된 솔레노이드 마그네트의 임계 전류 특성 및 임계 전류를 결정짓는 위치를 알아내기 위해, 솔레노이드 모델의 자장 분포 및 수직 자장 성분과 평행 자장 성분을 구하고 임계 전류는 비선형 방정식을 수치적인 방법을 이용하여 예측해보았다.

  • PDF

이중 경사 자장 에코와 일반 경사 자장 에코 펄스열로부터의 $\Delta{R}_1$$\Delta{R}_2$에 대한 컴퓨터 가상 실험

  • 김대홍;김은주;서진석
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.102-102
    • /
    • 2002
  • 목적:$\Delta{R}_1$$\Delta{R}_2\;^{*}$$T_1$, $T_2\;^{*}$로부터 직접 구해야 하지만, 시간 해상도 때문에 각각 $T_1$, $T_2\;^{*}$ 강조영상으로부터 구하는 것이 일반적이다. $T_1$, $T_2\;^{*}$ 강조영상으로부터 얻은 $\Delta{R}_1$$\Delta{R}_2\;^{*}$ 과 이중 경사 자장에코 펄스열로부터 얻은 $\Delta{R}_1$$\Delta{R}_2\;^{*}$ 를 컴퓨터 가상 실험을 통해서 비교한다. 강조 영상의 신호 세기만으로는 정확한 관류 정보를 얻을 수 없음을 보이고자 한다. 대상 및 방법: 알려진 $\Delta{R}_1$$\Delta{R}_2\;^{*}$ 값을 이용하여 강조영상으로부터 구할 수 있는 $\DeltaR_1$$\Delta{R}_2\;^{*}$ 을 농도에 따라서 가상실험으로 구하고, 이 값과 이중 경사 자장 에코 펄스열로부터 구할 수 있는 $\Delta{R}_1$$\Delta{R}_2\;^{*}$를 가상실험으로 구해서 비교한다.

  • PDF

Computation of Magnetic Thin-Film Head Field with the Boundary Element Method (경계 요소법에 의한 자기 박막 헤드의 자장 계산)

  • Ahn, Chang-Hoi;Lee, Soo-Young;Ra, Jung-Woong
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.3
    • /
    • pp.50-57
    • /
    • 1989
  • The fringe field of magnetic thin-film head is calculated with the Boundary Element Method (BEM), and the effects of a permeable underlayer to the head field are studied. It is found that the BEM can be efficiently used for this complex problem consisting of three different permeable regions, and the permeable underlayer effectively reduces the length of magnetic flux path and increases the fringe field.

  • PDF

Performance and Manufacture of the Apparatus Generating Artificial Magnetic Field of 3-axis Type (3축형 인공자장발생장치의 제작과 성능에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.3
    • /
    • pp.181-188
    • /
    • 2003
  • The objects of this study were to discuss the performance of its using magnetic compass and to do a trial manufacture of the apparatus generating artificial magnetic field of 3-axis type to assess the performance of compass using terrestrial magnetism in the various magnetic field. The results obtained were summarized as follows: The magnetic field of each axis showed the linearly increase in accordance with the increase of electrical current. Average range difference between measured and calculated values was 0.33∼1.93μT and there were no big difference. The magnitude and direction of magnetic field showed some change in the edge of Helmholtz coil, but it appeared to stabilize in the center. In the horizontal magnetic force of 0.30gauss and 0.40gauss, the measured and calculated values of the damping characteristic of magnetic compass showed a good agreement. However, the confidence level was low at the horizontal magnetic force of 0.50gauss.

Characteristics of Heat Transfer of Natural Convection for Magnetic Fluids in Annular Pipes (이중원관내 자성유체의 자연대류에 대한 전열특성)

  • Park, J.W.;Jun, C.H.;Seo, L.S.;Ryu, S.O.
    • Journal of the Korean Magnetics Society
    • /
    • v.12 no.2
    • /
    • pp.73-79
    • /
    • 2002
  • Compared with Newtonial fluids, magnetic fluids have effects on magnetic force. In this study, the purpose is to research the heat transfer characteristic of magnetic fluids which have metalic and fluid characteristics as the external pipe is being cooled and internal pipe is heated. This study found the experimental results from the study of the variety of natural convection for magnetic fluids and the characteristics of the heat transfer by using numerical analysis according to the strength and direction of the magnetic fields from being imposed from the outside. Natural convection of magnetic fluids was controlled by the impressed magnetic fields, and the result of mean nusselt number was calculated. If the impressed magnetic field is in the direction of gravity or the strength of impressed magnetic field is more than -14 mT in the opposite direction, the heat transfer is more than that without the impressed magnetic field. If the strength of impressed magnetic field is less than -14 mT in the opposite direction, it is smaller than that without the impressed magnetic field. Especially, when the strength of the magnetic field is -14 mT, the heat transfer was at the minimum.

Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances (가정용 전기기구에서 발생하는 자장과 유도전압의 측정과 분석)

  • 이복희;이동문;장영태;장근철;엄주홍;강성만;이승칠;박정용
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.51-59
    • /
    • 2002
  • This paper deals with the measurement and analysis of the induced voltages and magnetic fields caused by the operation of home appliances. The induced voltage and magnetic field measurement circuit used in this work consists of the induction coil, the operational preamplifier and the active integrator. Television set and monitors for personal computer cause strong magnetic fields rich in harmonics and high induced voltages by using the switching power suppliers. The strong magnetic field intensity and high induced voltage were created by 14" television set, and their values are 2.1 [$\mu$Tp-p]and 140 [mVp-p]at the distance of 0.4 [m], respectively. However, the induced voltage per unit magnetic field intensity was created by 17" monitor for personal computer and the measured data was approximately 560[mV/$\mu$T]at the same distance. distance.