Browse > Article
http://dx.doi.org/10.5207/JIEIE.2002.16.6.051

Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances  

이복희 (인하대 공대 전자전기공학부)
이동문 (한진중공업)
장영태 (인하대 산업대학원 전기공학과)
장근철 (인하대 대학원 전기공학과)
엄주홍 (인하대 대학원 전기공학과)
강성만 (인하대 대학원 전기공학과)
이승칠 (한진중공업)
박정용 (인하공업전문대학)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.16, no.6, 2002 , pp. 51-59 More about this Journal
Abstract
This paper deals with the measurement and analysis of the induced voltages and magnetic fields caused by the operation of home appliances. The induced voltage and magnetic field measurement circuit used in this work consists of the induction coil, the operational preamplifier and the active integrator. Television set and monitors for personal computer cause strong magnetic fields rich in harmonics and high induced voltages by using the switching power suppliers. The strong magnetic field intensity and high induced voltage were created by 14" television set, and their values are 2.1 [$\mu$Tp-p]and 140 [mVp-p]at the distance of 0.4 [m], respectively. However, the induced voltage per unit magnetic field intensity was created by 17" monitor for personal computer and the measured data was approximately 560[mV/$\mu$T]at the same distance. distance.
Keywords
Induced voltage; Incident magnetic field; Preamplifier; Active integrator;
Citations & Related Records
연도 인용수 순위
  • Reference
1 William F. Horton, Saul Goldberg, “Power Frequency Magnetic Fields and Public Health”, CRC Press, pp. 5-85, 131-178, 1995.
2 E. Zemman, S. Frei, et al., “Investigations of Exposition to Low Frequency Magnetic Fields”, 9th ISH, 8347-1-4, 1995.
3 R. P. Corcoran, “Extremely Low Frequency Exposure Limits Relative to Military Electrical/Electronic System Environments”, IEEE Int. EMC Symposium, pp. 62-67, 1992.   DOI
4 “IEEE Standard Procedures for Measurement of Power Frequency Electric and Magnetic Fields from AC Power Lines”, ANSI/IEEE Std. 644-1987, pp. 17-21, 1992.
5 J.P. Hauser, "A 20 Hz to 200 kHz Magnetic Flux Probe for EMI Surveys", IEEE Trans., Vol. EMC-32, No. 1, pp. 67-69, 1990.   DOI   ScienceOn
6 이복희, 이정기, “345/154kV 초고압 송변전설비 주변에서 의 자장의 측정과 분석 ”, 대한전기학회 논문지, Vol. 46, pp. 414-420, 1997.
7 TCO′99-Mandatory and Recommended Requirements for CRT-type Visual Display Units(VDUs) concerning:", pp11-13, 1999.
8 S. A. Macintyre, “A Portable Low Noise Low Frequency Three-axis Search Coil Magnetometer”, IEEE Trans. MAG, Vol. MAG-16, No. 5, pp. 761-763, 1980.   DOI
9 이복희, 이승칠, 안창환, 길형준, 전덕규, 길경석, “345[kV] 송전철탑 주변에서 전장과 자장의 측정과 분석”, 조명.전기설비학회 논문지, Vol. 12, No. 3, pp. 14-21, 1998   과학기술학회마을
10 W. Kohler, “Measurement and Calculation of Low Frequency Electric and Magnetic Fields”, 9th ISH, 8338- 1-4, 1995.
11 AC fields working group of the IEEE, “An Evaluation of Instrumentation Used to Measure AC Power System Magnetic Fields”, IEEE Trans. PD, Vol. 6, No. 1, 1991.   DOI   ScienceOn