• Title/Summary/Keyword: 자외선 강도

Search Result 220, Processing Time 0.028 seconds

Distribution of Ultraviolet Intensity and UV Leaking of Commercial UV Sterilizers Used in Restaurants (음식점에서 사용하는 자외선 살균소독기 내 자외선 강도 분포 및 자외선 누출)

  • Mok, Chul-Kyoon;Lee, Nam-Hoon
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.228-233
    • /
    • 2008
  • Ultraviolet sterilizers (UVS) are widely used in restaurants, cafeterias and catering businesses in Korea. The proper application of UVS, however, is still questionable since no studies have clearly identified their efficacy and safety, while regulations and regulatory management systems are yet to be established. In the present study, the efficacy of UVS were investigated by measuring spatial UV intensity inside five commercially operated UVS. The operating safety parameters were also checked by measuring leaked UV intensity. The UV intensities were inversely proportional to distance from the UV lamp within 25 cm, and to the square of the distance exceeding 25 cm. The UV intensities in commercial UVS varied with the distance from UV lamp and the incident angle, highlighting efficacy and stability concerns. Notable leakage was detected through the door gaps of a studied UVS, which also brought about safety concerns. Allowable working distances for the UV leaking UVS were suggested based on international standards.

Sensitivity Characteristics of Side-Polished Fiber Optic UV Sensor with Optical Intensity Variation (측면연마 광섬유형 자외선센서의 광강도 변화에 따른 감도특성)

  • Lee, Dong-Rok;Seo, Gyoo-Won;Yoon, Jong-Kuk;Cho, Kang-Min;Kang, Shin-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.6
    • /
    • pp.53-58
    • /
    • 2004
  • A novel UV sensor was manufactured and characterized using evanescent field coupling between photochromic dye dispersed polymer waveguide and side polished fiber. The spiroxazine (photochromic dye) dispersed polymer was used as planar waveguides. The resonant wavelength was shifted owing to refractive index variation of planar waveguide on exposed UV because of its photo-functional properties. The sensitivities are $1.21{\mu}W/mw$ and $2.75{\mu}W/mw$ when UV intensities increased after exposure times were fixed at 3 seconds and 5 seconds, respectively. Output optical power according to UV intensity increases and saturation time decreases as the intensity of UV radiations increases.

EFFECTS OF INTENSITY VARIATIONS IN UV AIR TREATMENT SYSTEMS (자외선 처리 시스템의 강도 변화에 대한 영향)

  • Kim, Jeong-Ho;Hong, Seung-Heun
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2017.11a
    • /
    • pp.271-272
    • /
    • 2017
  • 자외선 에너지는 미생물의 DNA를 파괴함으로써 살균 효과를 일으킨다. 자외선 방사로 공기 중 미생물에 대하여 높은 살균력을 얻기 위해선 강한 자외선 강도와, 흐르는 공기가 충분한 시간 동안 강한 자외선에 노출되어야 하므로 균일한 자외선 방사는 매우 중요하다. 기존 UV살균 시스템은 강한 자외선 에너지와 공기의 빠른 이동에 필요한 UV방사의 균일성을 제공하지 않았다. 하지만 HDS의 BioProtector 제품에 사용된 Advanced UV System(AUVS) 반사 캐비티 기술은 매우 높은 수준의 균일성을 생성함으로써 이 문제에 대한 해결책을 제공하며, 미생물 살균에 가장 효과적인 UV파장을 사용하여 6 LOG KILL (100만마리의 미생물 투입시 1마리 이하생존) 수준의 살균 효과를 만들었다.

  • PDF

The Changes in Properties of Silk Fabrics Dyed with Safflower under Ultraviolet-Light (홍화 염색 견직물의 자외선에 의한 성능 변화 연구)

  • Shin, Youn-Sook;Choi, Seung-Youn
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.7
    • /
    • pp.1-6
    • /
    • 2008
  • The purpose of this study was to investigate the changes in properties of silk fabrics dyed with safflower red and yellow colorants under Ultraviolet(UV)-light. Silk fabrics dyed with safflower red and yellow colorants were compared with each other after uv-light exposure in terms of K/S value, color changes(${\Delta}E$), morphology, and strength retention. The K/S value rapidly decreased with increasing exposure time for samples of both colorants, but the extent of decrease was less for the samples dyed with safflower yellow colorant, than that of the samples dyed with safflower red colorant. Regarding the color changes with increasing exposure time, $L^*$ and $b^*$ increased, $a^*$ decreased, and thereby ${\Delta}E$ increased in the red-dyed samples, whereas $L^*$ increased, $a^*$ and $b^*$ decreased, and so ${\Delta}E$ increased in the yellow-dyed samples, indicating that the UV-light induced fading and changes of hue, value and chroma value. However, the color change of the yellow-dyed samples was less than that of the red-dyed samples. SEM images showed a severe degradation by UV-exposure for both colorant samples. Tensile strength slowly decreased until 14 days, but rapidly decreased thereafter. Strength retention of the yellow-dyed samples was higher than that of red-dyed samples.

A Study on the Changes in the Property of Nylon Fabrics Dyed with Safflower Under Ultraviolet-Light(UV) - Focused on the Changes in Color, Strength, and Surface - (홍화 염색 나일론 직물의 자외선에 의한 특성 변화 - 색상, 강도 및 표면 특성 변화를 중심으로 -)

  • Shin, Youn-Sook;Choi, Seung-Youn
    • Journal of the Korean Home Economics Association
    • /
    • v.46 no.9
    • /
    • pp.1-6
    • /
    • 2008
  • The purpose of this study was to investigate the changes in the property of nylon fabrics dyed with safflower red and yellow colorants under Ultraviolet(UV)-light. For this purpose, nylon fabrics dyed with safflower red and yellow colorants were compared with each other after uv-light exposure in terms of K/S value, color changes(${\Delta}E$), morphology, and strength retention. K/S value rapidly decreased with increasing exposure time, but K/S value of the samples dyed with safflower red colorants decreased less than that of samples dyed with safflower yellow colorants. In color changes, as increasing exposure time, $L^*$ increased, $a^*$ decreased, $b^*$ increased, and so ${\Delta}E$ increased in samples dyed with safflower red colorants. In color changes, as increasing exposure time, $L^*$ increased, $a^*$ and $b^*$ decreased, and thereby ${\Delta}E$ increased in the samples dyed with safflower yellow colorants, indicating fading away by uv-light and changes of hue, value and chroma value. But the color change of samples dyed with safflower yellow colorants was less than that of samples dyed with safflower red colorants. SEM pictures showed a severe degradation by uv exposure, regardless of colorants type. Tensile strength slowly decreased until 14 days, and rapidly decreased until 28 days. Strength retention of the samples dyed with safflower yellow colorants was higher than that of the samples dyed with safflower red colorants.

Development of an UV Distribution Model for the Design of a Submerged UV Disinfection Reactor and Its Application (침지형 자외선 살균조 설계를 위한 자외선 분포 모델의 개발 및 적용)

  • Park, Changyeun;Kim, Sunghong;Choi, Younggyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.505-512
    • /
    • 2021
  • A 3D model was developed to calculate the UV intensity of a submerged-type UV disinfection reactor. Numerical experiments were conducted by inputting the design factors of an open channel-type disinfection reactor and a pipe-type disinfection reactor that were installed in an actual sewage treatment plant. The following data were obtained: The average UV intensity of the installed open channel-type reactor and pipe-type reactor was 7.87 mW/cm2 and 13.09 mW/cm2, respectively; the UV dose reflecting the UV irradiation time and taking into account attenuation effects such as mixing imbalance, lamp aging, temperature, and fouling, was expected to be 21.1 mJ/cm2 and 24.8 mJ/cm2, respectively, and these values are 5 % and 24 % higher than the target UV dose of 20 mJ/cm2, respectively. By using the UV3D model, the optimal lamp position, which maximizes the average UV intensity without changing the size of the disinfection reactor or lamp output power, can be found. In this case, by only adjusting the lamp position, the average UV intensity can be increased by 0.9 % for the open channel-type and 0.5 % for the pipe-type, respectively. A better average UV intensity can be obtained by model simulation. By adjusting the horizontal and vertical ratio of the open channel-type reactor and by moving the lamp position, the average UV intensity can be increased by 7.4 % more than the present case.

Evaluation of Mechanical Property Variation of Epoxy Based Compliant Polymer Concretes Exposed to UV Light (에폭시 기반 연성 폴리머 콘크리트의 자외선 노출에 의한 기계적 물성평가)

  • Roh, In-Taek;Jung, Kyung-Chae;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.27 no.6
    • /
    • pp.236-241
    • /
    • 2014
  • This paper aims to evaluate material property variation of polymer concretes under ultra-violet exposure condition. The components and mixing ratio of the polymer composite specimens were determined by the previous research results. The equivalent UV exposure time was calculated with the consideration of the power of metal halide lamp and maximum 3 years were selected for the experiments. From the tests, it was found that the generated heat during UV exposure affected much the material properties of polymer concrete by means of post cure. As a result, the compressive strength increased and ductility factor decreased.

Optical characteristics of the UV intensity distribution in a non-contact type UV photoreactor (비접촉식 자외선 반응조에서 자외선 강도 분포의 광학적 특성)

  • Jeon, Hwa-Bong;Yun, Jung-Won;Kim, Sung-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2012
  • The concept of a non-contact type of UV disinfection system was introduced in this study. UV lamps and their quartz sleeves hang over the water surface and there is no interface between the sleeve and water. Obviously, there is no fouling. Based on optical laws and other UV distribution models, a detail mathematical model for a non-contact type UV disinfection system was developed in this study. Pathway length of UV light in a non-contact type photoreactor is longer than that in a submerged type photoreactor because the light is more refractive while passing through 3 interfaces of medium. But the pathway length passing through the water media is not significantly longer than that in a submerged type photoreactor so, the absorption of UV light by water is not significantly different from the other system. Due to the reflection effect, UV intensity is rapidly decreased as the horizontal distance from the light source is increased. The reflective attenuation in a non-contact type photoreactor is higher than that in a submerged type photoreactor. These mean that the short photoreactor is advantageous than the narrow-long photoreactor for the non-contact type photoreactor in an optical point of view.

Estimation of Application of Artificially Deteriorated Silk by Ultraviolets for Conservation of Paintings on the Silk (견본 회화보존처리에 자외선 인공열화견의 적용성 평가)

  • Oh, Joon-Suk;Chun, Ji-Youn;Lim, In-Kyung
    • Journal of Conservation Science
    • /
    • v.27 no.2
    • /
    • pp.191-199
    • /
    • 2011
  • A study was done to compare the properties of artificially deteriorated silk with ultraviolets for reinforcing of loss area of paintings on silk. Deteriorated surface of raw silk irradiated by long-wavelength ultraviolet(UV-A) than short-wavelength ultraviolet(UV-C) was similar to naturally aged raw silk. UV-A irradiation raw silk was slowly decreased in tensile tenacity and elongation and lowered in yellowness index than that of UV-C. Water content of UV-A irradiation raw silk than that of UV-C was higher. UV-A irradiation raw silk had no problem in dyeing and inpainting for conservation because of low yellowness index. UV-C irradiation raw silk was brittle, but UV-A irradiation raw silk was seemed to tough and similar to naturally aged raw silk. Korean painting conservator estimated that UV-A irradiation raw silk was more proper for reinforcing of loss area of paintings on silk than that of UV-C.

Ultraviolet Inactivation of Escherichia coli in Stainless Steel Cups (스테인리스스틸 컵 내 Escherichia coli의 자외선 살균)

  • Mok, Chulkyoon;Lee, Nam-Hoon
    • Food Engineering Progress
    • /
    • v.13 no.2
    • /
    • pp.122-129
    • /
    • 2009
  • Ultraviolet (UV) is widely used as a sterilizing agent in restaurants and catering facilities in Korea. Efficacy of UV sterilizers (UVS) was investigated against E. coli on the inner bottom of stainless steel cups. UV intensity on the bottom of cups varied widely with the locations of cups in UVS, showing higher values at center while lower values at outskirts. The deviations in UV intensity were remarkable on top shelf, but alleviated as proceeded to middle and bottom shelves. Inactivation of E. coli was proportional to the UV intensity and treatment time, consequently to UV dose, and showed a pseudo-first-order kinetics with tailing. Initial inactivation rate constants ($K_{1}$) deviated with the locations of the cups, while final inactivation rate constants ($K_{2}$) showed comparable values. An equation for the calculation of the proposed UV treatment time was suggested.