Abstract
Ultraviolet sterilizers (UVS) are widely used in restaurants, cafeterias and catering businesses in Korea. The proper application of UVS, however, is still questionable since no studies have clearly identified their efficacy and safety, while regulations and regulatory management systems are yet to be established. In the present study, the efficacy of UVS were investigated by measuring spatial UV intensity inside five commercially operated UVS. The operating safety parameters were also checked by measuring leaked UV intensity. The UV intensities were inversely proportional to distance from the UV lamp within 25 cm, and to the square of the distance exceeding 25 cm. The UV intensities in commercial UVS varied with the distance from UV lamp and the incident angle, highlighting efficacy and stability concerns. Notable leakage was detected through the door gaps of a studied UVS, which also brought about safety concerns. Allowable working distances for the UV leaking UVS were suggested based on international standards.
Keywords
ultraviolet (UV) sterilizers; intensity; efficacy; leakage; safety;
Citations & Related Records

Times Cited By SCOPUS : 3
연도 인용수 순위
1 Seward II RA. Characteristics of Food Hazards. pp. 11-18. In: Food Safety Handbook. Schmidt RH, Rodrick GE (eds). John Wiley & Sons, Inc., Hoboken, NJ, USA (2003)
2 NIOSH. Ultraviolet Transfer Standard Detectors and Evaluation and Calibration of NIOSH UV Hazard Monitor. HEW Publication. No. 75-131. National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Atlanta, GA, USA (1975)
3 U.S. EPA. Ultraviolet Disinfection Guidance Manual. United States Environmental Protection Agency, Office of Water, Environmental Protection Agency, Washington DC, USA (2003)
4 Living Pure. A primer on UV-C light. Available from: http://www.livingpure.co.uk/hygienitech_uv_light_primer.pdf. Accessed Sep. 17, 2007
5 NRPB. Protection against Ultraviolet Radiation in the Workplace. National Radiological Protection Board, London, UK (1977)
6 Shama G. Ultraviolet light. pp. 2208-2214. In: Encyclopedia of Food Microbiology, 3rd ed. Robinson RK, Batt C, Patel P (eds). Academic Press, London, UK. (1999)
7 WHO. Environmental Health Criteria 14: Ultraviolet Radiation. World Health Organization, Geneva, Switzerland. pp. 61-94 (1979)
8 Marriot NG. Principles of Food Sanitation, 4th ed. Aspen Publishers, Inc., Gaithersburg, MD, USA. pp. 139-157 (1999)
9 Heinz Company. Principles and Practices for the Safe Processing of Foods, Butterworth-Heinemann Ltd., Oxford, UK. pp. 221-253 (1991)
10 Stanfield P. Cleaning and sanitizing a food plant. pp. 101-114. In: Food Plant Sanitation. Hui YH, Bruinsma BL, Gorham JR, Nip W, Tong PS, Ventresca P (eds). Marcel Dekker, Inc., NY, USA (2003)
11 KFDA. Outbreak of Food Borne Diseases in 2006. Korea Food and Drug Administration, Seoul, Korea (2007)
12 Bintsis T, Litopoulou-Tzanetaki E, Robinson R. Existing and potential applications of ultraviolet light in the food industry-a critical review, J. Sci. Food Agric. 80: 637-645 (2000)   DOI   ScienceOn
13 Lee NH, Kim NI, Mok C. Usage of ultraviolet sterilizers used in domestic restaurants and catering businesses. Food Engineering Progress 11: 225-229 (2007)
14 ACGIH. Threshold Limit Values and Biological Exposure Indices for 1986-1987, American Conference of Governmental Industrial Hygienists, Cincinnati, OH, USA. pp. 104-106 (1987)