• Title/Summary/Keyword: 자동 Shut-off

Search Result 9, Processing Time 0.021 seconds

Validating Timing of Vehicle Automatic Shut-off and Study on Appropriate Shut-off Timing (자동 Shut-off 시간 적정성 검증 방법 및 최적 시간 설정 방안 연구)

  • Yang, Dong Il;Choi, Byeong Nam;Park, Ji Woon;Yu, Min Sang;Beema, Stephanie
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.2
    • /
    • pp.15-23
    • /
    • 2021
  • Even though the number of CO poisoning casualties caused by unintended idling for the vehicles equipped with keyless ignition systems is more than 70, the problem still remains unsolved and became social issue in the US, and Senates introduced the bill which urges NHSTA to make regulation for this accordingly. To meet market safety needs and the regulations, we decided to provide automatic shut-off system very soon. In this paper, we would like to describe how to validate vehicle shut-off timing including defining required tests and case selections considering vehicle condition, garage/room size and temperatures with several assumptions. We believe that safe implementation of the shut-off function is possible via this methodology and the results. As NHTSA must be interested in shut-off timing, the methodology can be enhanced and conclusions could be reflected highly in the future regulation in case we continue this study with NHTSA or any other 3-rd party institutes.

Study on Divice for the Automatic Shut Off of Equipment Stand-by Power (자동전원 계폐장치에 관한 연구)

  • Kim, H.K.;Hyun, K.W.;Bae, J.I.;Yang, S.Y.;Park, S.T.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2626-2627
    • /
    • 1999
  • The device we have developed is the automatic shut off equipment which will reduce energy consumption when an equipment is in stand by power state. The principle for this system is when a man is moving, electricity will flow by setting a on-off light system. At night, in the stand-by power state the electric supply will be shut off immediately which will reduce energy consumption. Energy consumed by 24hour operating machines and stand-by electronic devices will be reduced by pulse signals which will give power supply when needed.

  • PDF

Development of the Leakage Current Detection Module for a Concent (콘센트용 누전감지 모듈 개발)

  • Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.3
    • /
    • pp.447-452
    • /
    • 2013
  • In this paper, the leakage current detection and auto shut-off module for a concent has been developed. Existing leakage current detection modules are detecting resistive leakage current, using a resistive leakage current detection chip but the proposed leakage current detection module separates and detects resistive leakage current in the synthesis leakage current by only programming in a power processor MCU(MSP430). The module implemented by proposed method has early detection and auto shut-off feature at more than resistive leakage current 5mA, and has the advantage of easily adjusting resistive leakage current less or more than 5mA, because of resistive leakage current detection function being implemented by a program in MCU.

A Study on the Improvement of Preventive Measures for Improving the Safety of Chemical Reactor (화학반응기의 안전성 향상을 위한 예방조치 개선에 관한 연구)

  • Byun, Yoon Sup
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.4
    • /
    • pp.32-38
    • /
    • 2020
  • Based on the cases of fire and explosion accident in the chemical reactor, thr problems of preventive measures installed in the chemical reactor were analyzed. The chemical reactors produce a variety of chemicals and install rupture disk to relieve the pressure that rises sharply in the event of a runaway reaction. In order to maintain the function of the rupture disk, the emissions was allowed to be discharged into the atmosphere, resulting in fire and explosion accidents. As a way to improve this, safety instrumented system based on the safety integrity level(SIL3) was applied as a preventive measures for chemical reactor. Two emergency shur-off valves are installed in series on pipe dropping raw materials for chemical reactor so that the supply of raw materials can be cut off even if only one of the two emergency shut-off valves is operated during the runaway reaction. The automatic on/off valve is installed in parallel in the supply pipe of the reaction inhibitor so that the reaction inhibitor can be injected even if only one valve is opened at the time of the runaway reaction.

Reply-Type based Agent Generation of Legacy Service on One-way data transfer system (일방향 자료전달 시스템의 레거시 서비스 지원을 위한 응답구조 기반 에이전트 자동 생성)

  • Kim, Kyoung-Ho;Chang, Yeop;Kim, Hee-Min;Yun, Jeong-Han;Kim, Woo-Nyon
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.2
    • /
    • pp.299-305
    • /
    • 2013
  • Physical One-way Transfer, one of network Separating Network Technologies, shut off intrusion possibilities by removing data transfer line from external network to internal network. Physical One-way Transfer technology can not support legacy services based duplex transmission. Legacy services operating need agent for extra service with the support. But, Agent development have problems with adding cost and open internal protocols. In this papers, We analyzed legacy services between Control network and OA network in working SCADA systems, and based on the results obtained from the analysis, categorized the legacy services into three forms. We propose an agent generation method of the three service categories for Physical One-Way Transfer System. In addition, we design an automatic generation tool using the proposed method.

Experiment Study on Operation Model of Automatic Cylinder Valve by the Temperature Differences (온도차 변동에 따른 전자밸브 작동모델 실험적 연구)

  • Jang, Kap-Man;Eom, Seok Hwa;Kim, In Chan;Kim, Chung Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.6
    • /
    • pp.73-79
    • /
    • 2012
  • Currently, all domestic CNG vehicles have manual cylinder valves installed. These are inconvenient for drivers in case of a gas leak accident, because drivers have to stop the vehicle operation and manually close the valve. It makes difficult condition for drivers to quickly and properly respond to such accidents. In advanced European countries, they require Automatic cylinder valve installation, which has a structure where the valve is automatically shut off when the driver turns off the ignition in case of a gas leak. If this electric valve system is introduced in Korea, the safety of CNG buses will be improved with better functionalities. In this paper, in order to solve the structural problem of difficulty for a driver to identify the operational status of individual Automatic cylinder valves, an approach was made regarding temperature increase with pressure increase during CNG filling. it was estimated that the temperature increased approximately more than $30^{\circ}C$ due to pressure difference during the filling. Therefore, it was concluded from the experimental data that the valve of the container whose temperature did not increase did not operate, resulting in filling failure.

Design and Implementation of Standby Power Cutoff System for Smart Home Environment Based on Zigbee-MQTT (Zigbee-MQTT 기반 스마트 홈 환경에 적합한 대기전력 차단 시스템 설계 및 구현)

  • Jang, Young-Hwan;Yang, Seung-Su;Park, Seok-Cheon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.4
    • /
    • pp.129-135
    • /
    • 2017
  • Recently, with the development of IoT technology, there has been an increase in interest in the power consumption of the devices used by the internal devices. Especially, the standby power consumption during the main function of the devices is about 11% of the power energy and the problem of standby power interruption is suggested. However, there is a problem that the plug must be unplugged in order to substantially shut off standby power. Therefore, in this paper, we design and implement a standby power cutoff algorithm that can automatically control and manage users' participation in order to solve there problems. As a result of evaluating the implemented system, it was confirmed that the standby power interruption rate improved by about 5.89Wh on average compared to the existing system.

Fire-fighting Pump Approval Standard for Fire-fighting Trucks with an Additional Positive Displacement Pump (용적형 펌프를 추가한 소방자동차용 소방펌프의 성능 인정기준에 관한 연구)

  • Han, Yong-Taek;Sung, Ki-Chan;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.1
    • /
    • pp.104-110
    • /
    • 2016
  • Positive displacement pumps with high pressure and water capacity are used large fires in various high-rise buildings. This study provides information for a performance approval standard of fire pumps for fire trucks based on centrifugal pump standards enacted in 2012. An experiment was conducted with a positive displacement pump for three levels of performance from the approval standard (V-1, 2, and 3). The efficiency of the pump was included in the reference, which requires the approval of 65% performance, the same as a centrifugal pump. The water pressure is between 1.5 and 2.5 MPa, and the required flow rate was established as at least $0.31m^3/min$ and up to $3.0m^3/min$. A relief valve was added to adjust the shut-off pressure due to the structural characteristics of the positive displacement pump. A strainer was also installed to prevent damage to the inside of the pump due to foreign matter. However, the strainer includes a difference from the positive displacement pump to operate without a vacuum pump and the centrifugal pump. This is due to the additional approval standard portion of the positive displacement pump, which is expected to be selected for more variety of fire-fighting equipment and proactive responses to fire suppression in a high-rise buildings and large fires. In conclusion, this approval standard was enacted in January 2016.

Excess Flow Valves for Underground Gas Pipeline and their Performance Testing Equipment Development (연료가스 매몰배관용 과류차단밸브와 성능시험 장치 개발)

  • Lee, Ugwiyeon;Joo, Yukyung;Lee, Jinhan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.74-81
    • /
    • 2018
  • The Korean Government has proceeded petroleum gas pipeline construction business since 2014 for rural districts. The operating pressure of petroleum gas pipeline are from 25kPa to 75kPa which are different from that of natural gas pipeline. Petroleum gas pipeline pressure is ten or forty times higher than natural gas operating pressure. For this reason, petroleum gas pipeline has higher probability of accident occurrence from massive gas leakage. Korea Gas Safety Corporation begins to development excess flow valves and their performance testing equipment since 2017. The excess flow valves stop the gas flow when a overflow happened in gas pipeline. The excess flow valves are generally not installed in main pipeline, because that may block massive gas supply. So, the valves are installed in starting points of branch pipes. According to the number of house and amount of gas use, a shut-off point of exxcess flow valve is determined called as Trip Flow. The trip point is the most important thing of excess flow valve, so, it is required a equipment testing the performances of excess flow valve as trip point.