Abstract
Currently, all domestic CNG vehicles have manual cylinder valves installed. These are inconvenient for drivers in case of a gas leak accident, because drivers have to stop the vehicle operation and manually close the valve. It makes difficult condition for drivers to quickly and properly respond to such accidents. In advanced European countries, they require Automatic cylinder valve installation, which has a structure where the valve is automatically shut off when the driver turns off the ignition in case of a gas leak. If this electric valve system is introduced in Korea, the safety of CNG buses will be improved with better functionalities. In this paper, in order to solve the structural problem of difficulty for a driver to identify the operational status of individual Automatic cylinder valves, an approach was made regarding temperature increase with pressure increase during CNG filling. it was estimated that the temperature increased approximately more than $30^{\circ}C$ due to pressure difference during the filling. Therefore, it was concluded from the experimental data that the valve of the container whose temperature did not increase did not operate, resulting in filling failure.
현재 국내의 모든 CNG자동차에는 용기용 밸브로 수동밸브가 부착되어 있으며 가스누출 사고 시 운전자가 차량을 정지하고 수동밸브를 잠궈야 하는 불편한 점이 있어 누출 사고 시에는 운전자 등이 가스누출사고를 대응하는데 어려운 부분이 있다. 유럽의 선진국에서는 가스누출 시 운전자가 시동을 끄면 자동으로 닫히는 구조를 가진 전자밸브의 장착을 의무화 하고 있어 우리나라에서도 기능성이 증가된 전자식 용기밸브를 적용하는 것이 CNG 버스의 안전성을 향상 시킬 수 있는 좋은 기회일 것이다. 본 논문에서는 개개의 전자밸브의 작동상태를 운전자가 파악하기 어려운 구조적인 문제를 보완하기 위해서 충전 중 압력의 상승에 따라서 온도가 상승하는 현상에 착안하여 문제에 접근하였다. 충전 중 온도상승이 압력차에 따라서 약 $30^{\circ}C$ 이상이 발생하는 것을 이용하여, 데이터 확인 시 온도상승이 발생하지 않는 용기는 밸브가 작동하지 않아 충전이 이루어지지 않는 것으로 판단할 수 있는 실험적 결론을 얻었다.