• Title/Summary/Keyword: 입자 통과시간

Search Result 52, Processing Time 0.028 seconds

An Electrical Particle Velocity Profiler Using Particle Transit Time Across Uneven Inter-Gap Electrodes (비등간격 전극열에서의 입자 통과시간을 이용한 전기적 입자속도분포 검출기)

  • Kim, Tae-Yoon;Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.4
    • /
    • pp.297-302
    • /
    • 2008
  • We present an electrical particle velocity profiler using particle transit time across uneven inter-gap electrodes. We measure both the particle position and velocity from the voltage signals generated by the particles passing across sensing electrodes, thus obtaining the velocity profile of the particles in a microfluidic channel. In the experimental study, we use polystyrene microparticles to characterize the performance of the electrical particle velocity profiler. The particle velocity profile is measured with the uncertainty of 5.44%, which is equivalent to the uncertainty of 5% in the previous optical method. We also experimentally demonstrate the capability of the present method for in-channel clogging detection. Compared to the previous optical methods, the present electrical particle velocity profiler offers the simpler structure, the cheaper cost, and the higher integrability to micro-biofluidic systems.

Measurement of 100nm Polystyrene Latex sphere using electrical classification method (전기 이동도를 이용한 NIST100nm PSL입자의 측정기술개발)

  • 안강호;안진홍;윤진욱
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.56-56
    • /
    • 2002
  • 100 nm 이하의 구형입자를 짧은 시간에 정확히 측정할 수 있는 기술을 개발하기 위하여 하전된 입자를 전기장내에 투입한 후 이의 이동도를 측정하였다. 100 nm의 표준 입자를 초순수에 분산시킨 후 Collison atomizer를 이용하여 입자를 공기중에 분산시켰다. 이후 입자를 건조시킨 후 입자의 분산과정에서 하전된 입자를 방사능 전기 중화장치를 통과시켜 입자의 하전을 기저상태로 만들었다. 이 후 입자를 전기 이동도 측정장치에 투입한 후 전기 이동도 측정장치의 유량과 전압을 조절하면서 입자의 크기를 측정하였다.

  • PDF

환경관련 특허동향 - 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템(주식회사 대성그린테크)

  • 한국환경기술인연합회
    • Environmental engineer
    • /
    • s.324
    • /
    • pp.86-93
    • /
    • 2013
  • 본 발명은 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템에 관한 것으로서, 더욱 상세하게는 건축물에서 배출되는 오수의 유입량을 제어하면서, 산기장치를 이용하여 상기 오수에 일정량의 에어를 공급하여 슬러지의 침강과 부패방지를 유도하는 유량조정조와, 상기 유량조정조를 거친 오수를 응집 및 침전처리하고 가압부상에의해 슬러지를 처리하는 가압부상조와, 상기 가압부상조를 거친 오수에 포함되어 있는 질소, 인을 처리하는 무산소조와, 상기 무산소조를 거친 오수에 포함되어 있는 유기물을 수처리용 접촉 메디아(DSBB)에 의해 분해하는 생물막조와, 상기 생물막조를 거친 오수를 침전과정을 통해 침전된 슬러지를 외부로 배출하는 침전조와, 상기 침전조를 거친 오수를 분리막에 통과시켜 오수에 포함되어 있는 미생물, 세균등의 미세입자들을 제거하는 분리막조와, 상기 분리막조를 거친 오수에 포함되어 있는 미처리 미세입자를 여과기에 통과시켜 처리하는 여과조와, 상기 여과조를 거친 오수를 오존($O_3$) 또는 UV 살균 처리하는 소독조와, 상기 소독조를 거쳐 최종적으로 처리된 처리수를 일정시간 동안 체류시켰다가 건축물의 중수로 재이용하기 위해 방출시키는 저수조를 포함하여 이루어지는 녹색 건축물에 적용되는 중수도 설치를 위한 수처리 시스템에 관한 것이다.

  • PDF

Pratical Use of Capillarity in Nutrient Solution Trickle Supply (점적 양액공급에 있어서 모세관 현상의 이용)

  • 장전익;김우일
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 1998.05a
    • /
    • pp.122-127
    • /
    • 1998
  • (1) 급액천의 규격별 양액공급량 $\bigcirc$ 합섬(비스코스+레이온) : 시간당 소(12.6ml), 중(21.2ml), 대(57.5ml)의 순으로 유입되었으며 중과 대의 급액천의 유입은 거의 같아 급액천의 규격간에 공급량은 비례하지 않았다. $\bigcirc$ 합섬(폴리에스텔) : 소(4.3ml), 중(20ml), 대(57.5ml)순으로 양액이 유출되었으며, $\bigcirc$ 합섬(인견) : 소(2.9ml), 중(23.7ml), 대(32.3ml)순으로 유입되었으나 소(급액천)의 유출량은 적어 급액천 재질로서 부적합하다고 생각되었으며, $\bigcirc$ 실(cotton) : 소(0.2ml), 중(3.0ml), 대(2.7ml)순으로 규격간에 유입은 차이가 없었으며 전체적으로 유출이 적어 급액천으로서는 부적합하였다. (2) 배지의 규격(종류)별 양액의 유입량 $\bigcirc$ 송이(Ф6.0mm~12.0mm이상) : 배지의 입자가 굵은 배지일수록 급액초기 1~2시간이 유입이 급격히 증가하였으나 시간이 경과할수록 일정한 량을 보였으며 유입량은 다른 배지에 비하여 많았고 급액천의 규격이 클수록 유입되는 량이 많았으나 시간이 경과함에 따라 감소하는 경향을 보였다. $\bigcirc$ 송이(Ф1~5mm) : 합섬A(비스코스+레이온)과 합섬B(폴리에스텔)에서는 시간당 15.0~50.1ml가 유입되었으나 합섬C(인견)과 실에서는 시간당 10ml이하로 토출량이 적었다. $\bigcirc$ 송이(Ф1~12mm) : 합섬A와 합섬B 급액천에서는 17.0~53.8ml가 유입되었으나 합섬C와 실에서는 시간당 평균 4.0~21.2ml가 흘러나와 배지의 공극이 일정하지 않아 시간당 통과하는 양이 일정하지 않았다고 생각되었다. $\bigcirc$ 펄라이트 : 합섬A(비스코스+레이온)급액천의 유입은 소(1$\times$60cm)에서 21.8ml, 중(2$\times$60cm) 33.5ml, 대(3$\times$60cm) 43.4ml가 통과되었고 합섬(폴리에스텔)에서는 19.0~30.7ml로서 급액천의 규격에 따라 통과되는 차이가 있었다. 배지가 규격화되어 있어 급액천의 규격별로 일정하게 유입되었으며 급액천의 재질이 유입에 영향을 미친 것으로 사료되었다. (2) 급액관과 베드상과의 높이에 따른 유출양 : 급액과 베드상과의 낙차가 클수록 유출이 증가함을 알수 있었으나 합섬C(인견)실험구에서는 낙차가 유출에 영향을 미치지 않았다. (4) 급액된 양액의 EC 및 pH조사 : 급액된 양액의 EC 및 pH에 전혀 변화가 없어 재배 적응에 문제가 없을것으로 사료되었다.

  • PDF

Electrcal Property of IGZO TFTs Using Nanoparticles

  • Lee, Jong-Taek;Park, In-Gyu;No, Yong-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.447-447
    • /
    • 2013
  • 최근 전자산업의 발전으로 차세대 디스플레이 소자로 산화물반도체가 주목받고 있다. 산화물 반도체는 저온공정, 높은 이동도 및 투과율을 가지기 때문에 이러한 공정이나 물성 측면에 있어 기존의 a-Si, LTPS 등을 대채할 만한 소자로서 연구가 활발이 이루어지고 있다. 특히 고해상도 및 고속구동이 진행됨에 따라 높은 이동도의 필요성이 대두되고 있다. 본 연구에서는 IGZO 산화물 반도체 박막트랜지스터의 이동도 개선을 위해 나노입자를 사용하였다. 게이트전극으로 사용된 Heaviliy doped P-type Si 기판위에 200 nm의 SiO2 절연층을 성장시킨 후, 채널로 작동하기 위한 IGZO 박막을 증착하기 전에 10~20 nm 크기의 니켈, 금 나노입자를 부착시켰다. 열처리 온도는 $350^{\circ}C$, 90분동안 진행하였고, 100 nm의 알루미늄 전극을 증착시켜 TFT 소자를 제작하였다. TFT 소자가 동작할 시, IGZO 박막 내부의 전자들은 게이트 전압으로 인해 하부로 이동하여 채널을 형성, 동시에 드레인 전압으로 인한 캐리어들의 움직임으로 인해 소자가 동작하게 된다. 본 연구에서는 채널이 형성되는 계면 부근에 전도성이 높은 금속 나노입자를 부착시켜 다수 캐리어인 전자가 채널을 통과할 때 전류흐름에 금속 나노입자들이 기여하여 전기적 특성의 변화에 어떠한 영향을 주는지 연구하였다. 반응시간을 조절하여 기판에 붙는 나노입자의 밀도 변화에 따른 특성과 다양한 크기(5, 10, 20 nm)를 갖는 금, 니켈 나노입자를 포함한 IGZO TFTs 소자를 제작하여 전달특성, 출력특성의 변화를 비교하였고, 실질적인 채널길이의 감소효율과 캐리어 이동도의 변화를 비교분석 하였다.

  • PDF

Properties of Nonwaxy Rice Flours with Different Soaking Time and Particle Sizes (수침시간과 입자크기가 다른 멥쌀가루의 특성)

  • Lee, Mi-Kyung;Kim, Jeong-Ok;Shin, Mal-Shick
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.268-275
    • /
    • 2004
  • Effects of soaking time and particle size on physicochemical properties of nonwaxy rice flour were investigated. Nonwaxy rice grains were soaked at $4^{\circ}C$ for 0, 1, 12, and 24 hr, dried at room temperature, and milled, Resulting flours were passed through 45-mesh ($<355{\mu}m,\;IL45$) and 100-mesh ($<150{\mu}m\;IL100$) sieves and separated into $<40{\mu}m\;and\;40-100{\mu}m$ series. IL45 series showed higher amount of large particles ($40-100{\mu}m$) than IL100 series. As the soaking time increased, protein and ash contents decreased, and amylose content, water-binding capacity, swelling power, and solubity of nonwaxy rice flours increased. Swelling power and solibility of nonwaxy rice flours also increased between $65-85^{\circ}C$. Water-binding capacity, swelling power, and solubility of IL100 series were higher than those of IL45 series. 12 hr-soaked nonwaxy rice flour pastes showed higher peak viscosity and breakdown but lower setback and visicosity at $95\;and\;50^{\circ}C$ than 1 hr-soaked ones. X-Ray diffractograms of nonwaxy rice flours were not affected, whereas surface appearance was affected, by soaking time and particle size.

Electron Microscopic Observations on the tissues infected with Nuclear Polyhedosis Virus of Bombyx mori during eary stage (가잠 핵다각체병 바이러스 초기감염에 관한 전자현미경적 관찰)

  • 유강선;강석권
    • Journal of Sericultural and Entomological Science
    • /
    • v.32 no.1
    • /
    • pp.49-57
    • /
    • 1990
  • To investigate the pathway of Nuclear Polyhedrosis Virus(NPV) of Bombyx mori in early stage infection of 2nd instar larva, the larval tissues were observed under electron microscope at interval of 6, 12, 24, and 48 hours after virus inoculation. The results are as follows. 1. The intact and enveloped nucleocapsids released from the polyhedra protein in the gut lumen apparently entered with the microvilli. 2. Virus progenies were observed in columnar cell nuclei 24 hours after inoculation, but polyhedra was not seen. The enveloped virus was observed in some of the intercellular spaces between mid-gut cells. 3. Many enveloped virus particles appeared in the basement membrane. These enveloped virus particles passed the basement membrane and gathered at blood cells in heomocoeal. 4. The NPV muliplicates in nuclei of the blood cells and the tracheal cells normally.

  • PDF

위성 영상과 해양 실측 자료를 활용한 부유사 농도 추정식 유도

  • Lee, Min-Seon;Park, Gyeong-Ae;Jeong, Jong-Ryul;Seo, Gang-Seon;An, Yu-Hwan;Mun, Jeong-Eon
    • 한국지구과학회:학술대회논문집
    • /
    • 2010.04a
    • /
    • pp.136-136
    • /
    • 2010
  • 해색원격탐사에서 해수 type을 광학적 성질에 따라 Case-I water와 Case-II water로 구분한다. Case-I water는 기본적으로 조류 세포 및 그 쇄설물 그리고 미량의 용존 유기물을 포함하며, 맑은 해수인 대양이 이에 속한다. Case-II water는 부유 무기입자, 육상 기원입자 및 높은 용존 유기물 농도, 인간이 만든 유입물을 포함한 탁한 해수이며, 연안 해역의 해수가 이에 속한다(Gordon, 1983). Case-II water에 속하는 연안 해역의 부유사 농도는 해양 연안 환경 변화를 모니터링 할 수 있는 중요한 지표 중 하나이다. 부유사가 연안 환경, 연안 양식장, 어장 환경에 어떤 영향을 주는지 파악할 수 있다. 채수를 통하여 부유사 농도를 추정하는 것은 시간적 경제적 제약이 따른다. 하지만 위성자료와 실측 자료간의 상관관계가 잘 나타나는 계수를 유도하면, 실측없이 위성영상만 있으면 연속적인 부유사 농도 분포를 볼 수 있을 것으로 기대된다. 이런 목적으로 Landsat ETM+ 자료를 이용하여 광양만의 표층 부유사 농도를 추정하였다. 위성 통과시간에 맞춰 2009년 9월 22일과 11월 25일 2차례에 걸쳐 부유사 농도와 반사도를 광양만 16개 정점에서 측정하였다. 부유사 농도는 표층의 해수를 채수하여 GF/F 필터를 이용해 측정되었고, 반사도는 Spectroradiometer를 사용하여 350nm부터 1050nm까지 1nm 간격으로 측정되었다. Landsat ETM+ 자료와 실측 반사도는 원격반사도 $R_{rs}$로 변환되었고, 두 가지 $R_{rs}$를 실측 부유사 농도와 비교하여 부유사 농도 산출 계수를 유도하였다. 경험적으로 구한 계수를 사용하여 위성영상을 부유사 농도로 계산하였으며, 이는 같은 날의 실측 부유사 농도와 비슷한 공간분포를 나타내었다.

  • PDF

Comparison of Utrasonic and Vibration Diagnostic Techniques for the Inspection of Pipes in CVD System (화학증착 시스템에서의 파이프내 오염입자 관찰을 위한 초음파 및 진동 진단법의 비교연구)

  • Yun Ju-Young;Seong Dae-Jin;Shin Yong-Hyoen;Lee Ji-Hun;Moon Doo-Kyung;Kang Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.421-426
    • /
    • 2006
  • In examining particulate deposits in the pipes of a chemical vapor deposition (CVD) system, vibration diagnostics is compared and studied against ultrasonic diagnostics, The latter method involves pulsing the outer wall of pipes with an ultrasonic sensor and analyzing the resulting echo to observe particulate deposits inside pipes. Vibration diagnostics examines the existence of particulate deposits by analyzing the difference in the frequencies generated when a vibrator is adhered to the outer wall of pipes. With ultrasonic diagnostics, good test results were obtained only when particulate deposits were attached to the inner wall of the pipes, After some time, however, particulate deposits were not detected properly, as the ultrasonic wave failed to cross the fine gaps created between the inner wall of the pipe and the deposits. The ultrasonic wave bounced back because of the dried particulate deposits on the wall. Thus, it has been proven that the ultrasonic diagnostics is not an appropriate means of examining the particulate deposits in a vacuum, On the other hand, vibration diagnostics succeeded in detecting the particulate deposits regardless of the lapsed time. In conclusion, the vibration diagnostics is being expected as the effective method in monitoring the particulate deposits inside pipes in the CVD system where the desired behavior is reduced frequency along with the particulate deposits in comparison to the case where the pipe is clean.

코로나 방전을 이용한 하이브리드 사이클론 집진 장치 특성 연구

  • Choe, Seong-Chang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.259-260
    • /
    • 2012
  • 산업화가 발달됨에 따라 대기 오염 물질은 점차 증가하고 있는 추세에 있고 특히 기름 및 석탄 연소 보일러, 자동차, 제철, 시멘트 플렌트, 소각로 등은 미세 분진을 발생시키는 주원인이 되어 왔다. 최근 대기환경법은 오염 분진의 중량 규제로부터 $10{\mu}m$ 미만의 PM10에서 $2.5{\mu}m$ 미만의 PM2.5의 미세 분진에 대한 규제로 점차 심화되고 있으나, 이러한 미세분진은 고전적인 제거 방법으로는 매우 어려우며 고가의 HEPA 필터를 사용하여야 한다. 한편 코로나 방전을 이용하는 전기 집진은 미세 먼지 제거에 매우 효율적이어서 $1{\mu}m$ 미만의 미세 분지도 99%까지 제거가 가능하다는 장점이 있지만 입자크기가 클 경우에는 효율이 떨어지는 단점이 있다. 한편 사이클론 집진기는 매우 오래전부터 개발되어 사용되어 왔는데 가격이 저렴하고 운영비가 적게 들며 $10{\mu}m$ 이상의 먼지는 99% 이상 제거가 가능하여 산업현장에서 오랜 기간 사용되어 왔지만 입자크기가 $10{\mu}m$ 미만으로 가면 집진율이 급격히 떨어지는 단점을 가지고 있다. 본 연구에서는 기존의 사이클론 집진기의 구조를 기본으로하여 사이클론 집진기 내부에 플라즈마 방전을 설치하여 원심력에 의한 집진과 코로나 방전에 의한 전기 집진을 동시에 수행할 수 있도록 하이브리드 사이클론 집진기를 제작하였다. 제작된 사이클론 집진기는 직경 30 cm 높이 120 cm의 사이클론 구조를 가지고 있으며 1 hp의 터보송풍기를 장착하여 $20m^3$/min 이상의 유량을 처리할 수 있도록 설계 제작되었다. 제작된 하이브리드 사이클론 집진기의 성능을 평가하기 위하여 $10m^3$의 체적을 가지는 테스트 챔버 내부에 사이클론 집진기를 설치하고 향을 태워 미세 먼지를 발생시킨 후 다양한 조건에서 집진 성능을 측정하여 보았다. 미세 먼지의 경우 사이클론을 작동시키지 않아도 테스트 챔버 벽면에 흡착되어 초기에는 급격히 감소하는 경향을 보여주나 일정 시간이 경과한 후에는 매우 느리게 감소하는 현상이 관찰 되었다. 코로나 방전을 하지 않고 오존 파괴기에 활성탄만 충진한 상태에서 사이크론을 작동시킬 경우 지속적으로 천천히 감소하는 경향을 보여주었으며, 코로나 플라즈마를 방전시킨 경우 미세 먼지는 HEPA filter를 장착한 것보다도 조금 빠르게 미세먼지를 제거하였다. 챔버 내부의 미세먼지가 초기 값의 1/10에 도달하는 시간은 코로나 방전 전류가 증가할수록 짧아지는 경향을 보여주었으며 최적 조건에서 100초 이내에 90% 이상 제거가 가능하였다. 하이브리드 사이클론 집진기는 집진 뿐 만 아리라 VOC 성분도 분해가 가능하여 유해물질을 제거하는 능력이 있다. 유해 가스 제거 능력을 실험하기 위하여 분진제거 실험에 사용된 챔버 안에 아세톤을 증발시켜 50 ppm이 되도록 한 후 다양한 조건에서 유해물질 제거 실험을 수행하였다. 미세먼지와는 달리 장비를 작동하지 않을 경우 매우 느리게 아세톤 농도가 감소하였다. 이는 미세 먼지와는 달리 흡착이 발생하지 않고, 측정 챔버 자체가 완전한 밀폐가 이루어지지 않아 자연적으로 조금씩 외부로 누출되기 때문으로 판단된다. 코로나 플라즈마만 방전시켰을 경우 초기 농도의 80%가 제거되는데 걸리는 시간은 약 28분 정도로 코로나 플라즈마가 VOC 제거에 효과가 있음은 확인하였으나 제거율이 그리 높지 않음을 알 수 있었다. 한편 오존 파괴를 위해 활성탄으로 충진 된 오존파괴기를 통과시킨 경우는 약 12분 경과 후 80%가 제거됨을 확인할 수 있었으나 그 이후에는 VOC의 감소가 매우 느리게 진행됨을 알 수 있었다. 한편 활성탄 대신 $MnO_2$ 복합촉매로 충진 된 오존파괴기를 통과한 경우 약 3분 정도 경과 후 80%의 아세톤이 제거됨을 관찰할 수 있었으며 코로나 플라즈마를 작동시키면서 $MnO_2$ 복합촉매로 충진 된 오존파괴기를 통과시킨 경우 약 2분 정도 경과 80% 이상의 아세톤이 제거되어 코로나 플라즈마와 복합촉매를 사용할 경우 VOC 성분이 효과적으로 제거됨을 알 수 있었다.

  • PDF