• Title/Summary/Keyword: 입력 직류전력

Search Result 127, Processing Time 0.021 seconds

A Study to Improve the DC Output Waveforms of AFE Three-Phase PWM Rectifiers (AFE 방식 3상 PWM 정류기의 직류 출력파형 개선에 관한 연구)

  • Jeon, Hyeon-Min;Yoon, Kyoung-Kuk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.739-745
    • /
    • 2017
  • Many studies have been conducted to reduce environmental pollution by ships and reduce fuel consumption. As part of this effort, research on power conversion systems through DC distribution systems that link renewable energy with conventional power grids has been pursued as well. The diode rectifiers currently used include many lower harmonics in the input current of the load and distort supply voltage to lower the power quality of the whole system. This distortion of voltage waveforms causes the malfunctions of generators, load devices and inverter pole switching elements, resulting in a large number of switching losses. In this paper, a controller is presented to improve DC output waveforms, the input Power Factor and the THD of an AFE type PWM rectifier used for PLL. DC output voltage waveforms have been improved, and the input Power Factor can now be matched to the unit power factor. In addition, the THD of the input power supply has been proven by simulation to comply with the requirements of IEEE Std514-2014.

Analysis of Input Characteristic in the PWM Converter with Unbalance Supply (불평형 전원 전압을 갖는 PWM 컨버터의 입력 전류 고조파 분석)

  • Khoo, Ja-Kyeung;Kim, Sang-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.179-181
    • /
    • 2005
  • PWM(Pulse Width Modulation) 컨버터에서 공급 전압의 품질은 교류 입력전류 및 직류 출력전압의 품질에 큰 영향을 미친다. 공급전압이 불평형 또는 고조파가 포함된 경우에는 평형 전원전압의 경우보다 입력 전류의고조파 및 역률 특성이 저하된다. 또한 컨버터 입력 측의 사용된 인덕턴스의 용량에 따라 입력전류의 고조파 및 역률 특성이 달라진다. 본 논문에서는 입력측 인덕턴스 값의 변화에 따른 단상 및 삼상 PWM 컨버터의 입력전류 고조파와 역률 관계를 해석하였는데, 특히 입력전압에 고조파를 포함한 경우와 불평형인 상태까지 확장하여 성능을 평가하였다. 이러한 결과를 통해 입력 인덕턴스 설계 값을 선정하는데 기준을 제시하였다.

  • PDF

Fault Diagnosis for 3-Phase Diode Rectifier using Harmonic Ripples of DC Link Voltage (직류단 전압의 고조파 맥동 검출을 이용한 3상 다이오드 정류기의 고장 진단)

  • Park, Je-Wook;Baek, Seong-Won;Kim, Jang-Mok;Lee, Dong-Choon;Lee, Kyo-Beum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.5
    • /
    • pp.457-465
    • /
    • 2011
  • The fault analysis and detecting algorithm for a 3 phase diode rectifier is proposed. The 3 phase dioderectifier is used for the AC power rectifier of the PWM inverter. The input power or diode faults cause theripples of the DC voltage, degradation of the control performance and life shortening of the DC link capacitor.In this paper, the ripple of the DC voltage is mathematically analyzed for the earth fault of input power andopen circuit fault of the diode, respectively. The fault detection and type of fault can be obtained by comparingthe average DC voltage and the instant DC voltage which is sampled with 6 times of grid frequency. Theproposed method can be easily applicable and doesn't require additional circuit. The experimental and simulationresults are presented to verify the validity of the proposed method.

Single-Stage High Power Factor Converter for 90-260Vrms Input (90-260Vrms 입력 범위를 갖는 단일 전력단 고역률 컨버터)

  • 김학원;문건우;조관열;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.18-29
    • /
    • 2002
  • Generally, the single-stage power factor corrected converter has a problem of high dc link voltage. In the case of high line voltage, especially, the dc link voltage is verb high under the light load condition. To solve this problem, a new single stage power factor corrected AC/DC converter has been proposed. The proposed converter has huck topology as a power factor corrector. To prove feasibility of the proposed converter, the design example of the proposed converter has been presented. The design considerations and experimental results for the proposed converter have been shown. The experimental results show that the line input current harmonics can meet IEC1000-3-2 Class D requirements for the range of line input voltage from 90Vrms to 260Vrms.

A Study on the Harmonic Current Characteristics of Universal Motro with Speed Controller (유니버셜모터 속도제어기의 고조파전류 특성에 관한 연구)

  • 임홍우;박수강;백형래
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.2
    • /
    • pp.132-140
    • /
    • 2001
  • A universal motor is a small dc series machine motor that is designed to operate from an ac machine. The characteristics of universal motors are high no-load and staring torque. Because of the high operating speed, the size of these motors for a given hp rating is typically smaller that other fractional hp ac machine, making it ideal for hand-held tools and appliances where weight, compactness, and speed are importance factors. A phase-angle control with AC drive system gains a high popularity due to their simple implementation, but contains the disadvantage of their poor input power factor, subharmonic current. Pulse width modulation control with DC drive systems increase the power factor as without delay phase angle. This paper analyzed the subharmonic characteristics of the phase angle control system that is controlled by zero voltage crossing similar to traditional method, and the dc chopper system that is used PWM.

  • PDF

Design of only PWM Controller Based on FPGA (FPGA를 기반으로 한 PWM전용 컨트롤러 설계)

  • Kim Sang-Ug;Rho Youn-Sung;Lee Jae-Young;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.842-845
    • /
    • 2004
  • PWM 입력 전압원 반브리지 직류-직류 변환기의 예로 통상적인 스위칭 방법으로 동작시킬 때, 직류 전압원의 단락을 방지하기 위하여 변환기 신호에 데드타임을 삽입한다. 이러한 데드타임은 변환기 시스템의 제어 성능에 좋지 않은 영향을 발생시킨다. 따라서 이 데드타임을 효과적으로 보상하는 것이 필요하다. 또 이 데드타임의 영향을 방지 할 수 있는 최선의 방법으로써 데드타임 최소화 스위칭 방법을 고려할 수도 있다. 본 논문에서는 데드타임 최소화 스위칭 방법의 하나인 아날로그 방법이 아닌 디지털 방법으로 스위칭 방법을 제안하였다. 제안한 스위칭 방법은 SOC를 기반으로 한 Verilog-HDL 언어를 이용하여 PWM전용 컨트롤러를 설계하고, 기존에 문제점으로 PWM 스위칭 발생시 과도기간 동안 턴오프 손실이 발생되어 저하된 효율를 제안된 방법으로 방지하였다.

  • PDF

DC-link Shaping Method in Boost Converter-Inverter System for Six-step Torque ripple Reduction (컨버터-인버터 시스템에서 6-스텝 시 토크 리플을 줄이기 위한 가변 직류단 전압 제어 방법)

  • Choi, Hyeon-gyu;Lim, Gyu Cheol;Ha, Jung-Ik
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.274-275
    • /
    • 2017
  • 부스트-인버터 시스템에서 6-스텝 시 토크 리플을 줄이기 위한 방법을 제시한다. 모델 기반의 전압 방정식을 통해 필요한 직류단 전압의 크기 및 위상을 구하고 전류 전향 보상을 통해 전압을 합성한다. 이를 통해 직류단 캐패시턴스를 수 ${\mu}F$까지 낮출 수 있어 캐패시터의 부피 및 비용을 절감할 수 있다. 이러한 최적 해 운전 시 생기는 입력 파워 리플의 문제점을 해결하기 위한 일정 파워 공급 방법을 제시하며 이를 통해 운전영역에 따른 적절한 운전 방법의 선택을 제시한다.

  • PDF

Design of High Voltage Conversion Ratio Power Conversion Circuit for Ionizer (이오나이저를 위한 높은 전압 변환비를 가지는 전력변환회로 설계)

  • So, Pyung-Ho;Choi, Yeon-Woo;Lee, Byoung-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.187-188
    • /
    • 2017
  • 이오나이저는 에어컨이나 공기청정기와 같은 전자기기에서의 공기 정화기능이나 반도체 장비에서 웨이퍼에 먼지가 부착 되는 문제를 해결하기 위한 정전기 제거 기능 등의 용도로 활용되고 있다. 이오나이저의 동작을 위해서는 교류나 직류 형태를 가지는 수 kV의 고전압을 발생시킬 수 있는 높은 전압 변환비를 가지는 전원장치가 필요하다. 본 논문에서는 5 V 전원을 입력으로 하고, 5 kV 전원을 출력으로 하는 직류 형태의 이오나이저용 전력변환회로의 소형화 및 저가격화를 목표로 설계하고 검증한 내용에 대하여 논의하고자 한다.

  • PDF

Photovoltaic DC Module Integrated Converter Control using Inductor Current (인덕터 전류를 이용한 태양광 직류 모듈 집적형 전력변환장치 제어)

  • Lee, Hee-Seo;Kim, Dong-Hee;Lee, Eun-Ju;Lee, Byoung-Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.25-26
    • /
    • 2012
  • 본 논문에서는 태양광 발전 시스템의 직류 모듈 집적형 전력변환장치를 인덕터 전류 및 입 출력 전압을 이용하여 MPPT 및 출력 전류 제한을 수행하는 제어 방법을 제안한다. 이를 통해 기존의 입 출력 전류 및 입력 전압을 이용하는 방식에 비해 전류 센서를 한 개 줄이면서 동일한 특성으로 제어가 가능하다. 또한 실험을 통해 제안하는 방식의 타당성을 검증한다.

  • PDF

Utility Interactive Photovoltaic Generation System Using Discontinuous Mode Buck-Boost Chopper (불연속모드 승강압초퍼를 이용한 계통연계형 태양광발전 시스템)

  • 김영철;이현우;서기영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.325-331
    • /
    • 1999
  • In a utility interactive photovoltaic generation system. a PWM inverter is used for the connection between the p photovoltaic arrays and the utility. The dc current becomes pulsated when the conventional inverter system operates i in the continuous current mode and de current pulsation causes the distortion of the accurrent waveform. This paper p presents the reduced pulsation of de input current by operating the inverter with buck-boost chopper in the d discontinuous conduction mode. The dc current which contains harmonic component is analyzed by means of s separating into two terms of a ripple component and a direct component. The constant dc current without p pulsation is supplied from photovoltaic array to the inverter. The proposed inverter system provides a sinusoidal ac c current for domestic loads and the utility line with unity power factor.

  • PDF