• Title/Summary/Keyword: 임플란트 환자

Search Result 497, Processing Time 0.024 seconds

A review of biocompatibility of zirconia and bioactivity as a zirconia implant: In vivo experiment (지르코니아의 생체적합성과 임플란트로서의 생체활성에 대한 연구: In vivo 실험 문헌 고찰)

  • Suh, Da-Won;Kim, Young-Kyun;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.88-94
    • /
    • 2019
  • Increasing demands for esthetic dental treatment, zirconia, which has high mechanical and esthetic properties, had been applied more and more in clinics. Therefore, assessment of biocompatibility of zirconia is necessary. In this article, a review of in vivo studies of zirconia compatibility was performed. In vivo studies showed zirconia had great biocompatibility both on soft and hard tissue. Studies with various animals and patients reported high biocompatibility of zirconia. In terms of bone synthesis and bone adhesion, zirconia showed similar biocompatible properties to titanium. On the other hand, zirconia could be used as implant. For using as an implant, various methods of Hydroxyapatite (HA) coating had been suggested. Since HA coating on titanium implant showed some problems such as low bonding strength and degeneration of HA, HA-zirconia composite, HA-coated zirconia, and HA-zirconia functionally graded material (FGM) or intermediate layer of alumina had been proposed. These methods showed higher bonding strength and biocompatibility.

Axial displacement in single-tooth implant restoration: Case report (임플란트 단일 치아 수복 시 수직 침하와 인접치와의 위치 변화: 증례 보고)

  • Jeong, Seung-Hoe;Kim, Sunjai;Chang, Jae-Seung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.126-133
    • /
    • 2021
  • Axial displacement of an implant-supported prosthesis is frequently reported in clinical and laboratory studies. However, limited information is available about the behavior of the axial displacement of implant-supported prostheses functioning in intraoral situations. The present case report evaluated the three-dimensional displacement of posterior single implant-supported prostheses in 2 different patients. Internal connection type implants were placed, and screw and cement-retained prosthesis (SCRP) type prosthesis were delivered after an appropriate healing period. Intraoral digital scans were performed using an intraoral scanner (Cerec Omnicam, Dentsply Sirona, USA) on the day of crown delivery and one week, one month, and one year after delivery. The amount of 3-dimensional displacement of the prosthesis was evaluated by using a digital inspection software (Geomagic Control X, 3D systems, USA). The axial displacement of implant-supported prosthesis occurred in both patients. Furthermore, the amount of displacement increased over time.

Considerations for minimizing food impaction after implant prosthesis: Adjacent and antagonistic teeth (임플란트 보철 후의 식편압입을 최소화하기 위한 고려사항: 인접치와 대합치)

  • Lee-Ra, Cho
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.31 no.2
    • /
    • pp.47-55
    • /
    • 2022
  • Food impaction due to proximal space opening after implant restoration is a very common phenomenon in patients who have implant prosthesis. This occurs because the movement mechanism between the implant and the tooth is different, and it occurs about 30-60% over time. Contributing factors include the arch (mandible), region (posterior teeth), adjacent teeth (non-vital teeth), and antagonist teeth (natural teeth or implants), etc. While this phenomenon cannot be prevented, efforts should be made to minimize it. In order to have an ideal proximal contact as much as possible, the concave shape or the prominent lower proximal shape should be modified to create a symmetrical proximal shape. with the buccal dentate in the upper third height should be adjusted. Other conditions should be modified so that the heights of the marginal ridges are similar. Since an irregular occlusal plane is a cause of poor prognosis, food impaction should be minimized by restoring the ideal occlusal plane by correcting the extruded antagonist and reduction of the disto-buccal cusp.

Fabrication of implant-associated obturator after extraction of abutment teeth: a case report (지대치 발거 후 임플란트 연관 상악 폐색장치 제작 증례보고)

  • Ki-Yeol Jang;Gyeong-Je Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.229-236
    • /
    • 2023
  • Maxillary bone defects may follow surgical treatment of benign and malignant tumors, trauma, and infection. Palatal defects often lead to problems with swallowing and pronunciation from the leakage of air into the nasal cavity and sinus. Obturators have been commonly used to solve these problems, but long-term use of the device may cause irritation of the oral mucosa or damage to the abutment teeth. Utilizing implants in the edentulous area for the fabrication of the obturators has gained attention. This case report describes a patient, who had undergone partial resection of the maxilla due to adenocarcinoma, in need of a new obturator after losing abutment teeth after long-term use of the previous obturator. Implants were placed in strategic locations, and an implant-retained maxillary obturator was fabricated, showing satisfactory results in the rehabilitation of multiple aspects, including palatal defect, masticatory function, swallowing, pronunciation, and aesthetics.

The Effects of Professional Tooth Cleaning and Plaque Control Instruction on Reduction of Peri-implantitis (전문가치면세정술과 세균막관리교육의 임플란트 주위염 감소 효과)

  • Park, Kyung-Hwa;Han, Gyeong-Soon
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.163-170
    • /
    • 2012
  • The purpose of this study was determine the effects of professional tooth cleaning and plaque control instruction(PT & PCI) on reduction of peri-implantitis. A total 80 implant patients were investigated using O'Leary plague index(PI), L${\ddot{o}}$e & Silness gingival index(GI), implant bone loss(BL). While the PT & PCI was conducted by using 'Watanabe method' after scaling for the experimental group, the engine polishing and a plaque control instruction was operated by rolling method after scaling for the control group. The collected data were analyzed with t-test, ANOVA, paired t-test and stepwise multiple regression. PI and GI of the experimental group significantly decreased than the control group(p<0.05). BL, also tended to decreased in the experimental group than the control group(p=0.155). Multiple regression analysis, the factors that was highly correlated with PT & PCI on the PI and GI. According to the implant characteristics, implant location and duration were closely related to PI(p<0.05). Therefore, the PT & PCI is one of the effective methods to reduce the failure caused by the peri-implantitis. Based on this conclusion, that it would be meaningful if the proposed PT & PCI is applied to the oral health management programs of the implant patients.

Full-mouth rehabilitation with vertical dimension increase and computer tomography guided implant surgery in patient with excessive worn dentition and multiple loss of tooth (과도한 치아 마모와 다수의 치아 상실을 보이는 환자에서 computer tomography guided implant surgery와 수직고경 회복을 동반한 완전 구강 회복 증례)

  • Lee, Kyong-Seop;Lim, Young-Jun;Kwon, Ho-Beom;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.1
    • /
    • pp.66-74
    • /
    • 2019
  • Excessive wear causes many complications when untreated, so that accurate diagnosis, analysis and predictive treatment plan should be made, and through evaluation of vertical dimension and stepwise treatment, a stable inter-arch relationship can be set. For the long-term success of implant treatment, ideal position and angle of implant is important, and its importance increases especially in multiple implant cases. Therefore, thorough diagnosis and planning, accurate surgery and prosthodontic procedures are significant. In this case, a 68-year-old male patient with a loss of vertical dimension due to multiple tooth loss and overall tooth wear was planned with systematic analyses from the pre-treatment stage to rehabilitate vertical dimension. Full-mouth fixed rehabilitation with computer tomography guided implant surgery was performed to the newly set vertical dimension and attained satisfactory outcomes both functionally and esthetically.

A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case (실패한 이중관 국소의치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Park, Jong-Hoon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.

Rehabilitation of posterior support and vertical dimension in a class 3 malocclusion patient: A case report (III급 부정교합 환자에서 상악 가철성 국소 의치와 하악 임플란트 지지 고정성 보철물을 이용한 구강 회복 증례)

  • Oh, Ji-Hwan;Pyo, Se-Wook;Chang, Jae-Seung;Kim, Sunjai
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.2
    • /
    • pp.175-186
    • /
    • 2022
  • A crossed occlusion resulting from the presence of posterior teeth in one arch but no opposing teeth in the opposite arch results in collapse of the vertical dimension. In this case, the patient has a class III malocclusion with crossed occlusion and anterior crossbite. In order to evaluate the proper vertical dimension, provisional denture was used to stabilize the vertical occlusal dimension for 3 months. After, provisional fixed restoration was used for the stabilizing occlusal relationship and aesthetic improvement for lip support. Definitive prosthesis in implants in the mandible and abutments in the maxillary were using Porcelain-fused-to-metal crown (PFM) crown and the maxillary unilateral edentulous area was treated with removable partial dentures. Through this, proper support of the posterior region and normal anterior occlusal relationship were formed, and the patient was able to obtain aesthetically and functionally satisfactory treatment results.

Head & Neck CT Scan Image Evaluation for Implant Surgery Patients (임플란트 시술환자에 대한 두경부 CT검사 영상 평가)

  • Hyung-Seok Hwang;Hyung-Seok Hwang;In-Chul Im
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.843-849
    • /
    • 2023
  • This study attempted to determine the optimal algorithm after quantitatively analyzing noise, SNR, and CNR measurements by reconstructing four algorithms (Standard, Soft, Bone, and Detail) from head and neck CT images of patients who underwent implant surgery. As an analysis method, pixel values were calculated through the region of interest in the reconstructed image using the Image J program. For noise, SNR, and CNR, the region of interest was measured at the location of the pharynx, masseter muscle, and parotid gland in the image, and the mean and SD values were obtained. The values of SNR and CNR were calculated based on the given formula. As a result, the standard algorithm showed the lowest noise and the highest SNR. CNR was highest in the Soft algorithm, but showed no significant difference from the Standard algorithm. Therefore, it is believed that the Standard algorithm is the optimal algorithm for examining patients wearing intraoral implants in head and neck CT examinations. We hope that the data from this study will be used as basic data for image evaluation in head and neck CT examinations, and that the quality of images will be further improved through various algorithm changes. It is believed that this will be an opportunity to do so.

Multiple fixed implant-supported prosthesis using temporary denture and scannable healing abutment: a case report (임시의치와 스캔가능한 치유지대주를 이용한 고정성 임플란트 보철 수복 증례)

  • Hyung-Jun Kim;Hyeon Kim;Woo-hyung Jang;Kwi-dug Yun;Sang-Won Park;Hyun-Pil Lim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.4
    • /
    • pp.250-259
    • /
    • 2023
  • The use of digital technology in fixed prosthetic treatment using implants enables predictive treatment through diagnosis and virtual surgery by integrating clinical and radiological information of patients. Existing digital scanning methods require several components to be removed, such as removing the healing abutment and connecting the scan body. In the scannable healing abutment developed in consideration of this point, scanning is performed directly on the healing abutment, maintaining soft tissue sealing and simplifying scanning. Digital technology can also be used when obtaining the intermaxillary relationship. Recently, various digital technologies have been reported to acquire the intermaxillary relationship of edentulous patients using surgical guides, patient-specific scanning devices, or scans of the inside of temporary dentures. In this case, the implant-supported fixed prosthesis treatment was performed through scanning the scannable healing abutment and the inner side of the temporary denture to obtain the intermaxillary relationship, thereby simplifying the treatment process and obtaining aesthetically and functionally excellent clinical results.