• Title/Summary/Keyword: 임플란트 종류

Search Result 87, Processing Time 0.027 seconds

Wettability of titanium implants depending upon surface properties (타이타늄 표면 처리 특성에 따른 젖음성에 관한 연구)

  • Han, Young-Soo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.1
    • /
    • pp.12-20
    • /
    • 2009
  • Statement of problem: When an implant is fixed, a fixture comes into contact with a tissue fluid. Adhesion of a tissue fluid to a surface of implant is various case by case. Purpose: The ultimate goal of this work is to analyze a correlation between a surface roughness and wettability of implant specimens. A measurement for wettability is performed considering 4 types of specimen implant with surface treatments different from each other to investigate the change of wettability with the elapse of time. Material and methods: Firstly, 20 specimens of titanium were prepared. The specimen were made of a commercial Titanium Grade IV with the diameter of 10 mm and the thickness of 1 mm. According to the method of surface treatment, the specimens were classified into 4 groups of 5 specimens per group. Group A: Machined Surface Group B: Anodized surface Group C: RBM (HA blasting) surface Group D: CMP (calcium methaphosphate) coating surface. Surface roughness of specimen was measured using SV-3000S4 (Mituyoto, Japan). The measurement was based on the standard of JIS1994. Sessile drop method was used to measure the wettability, which measures contact angle between implant disc and saline with the time interval of 5, 10, and 15 seconds. SPSS 11.0 was used to analyze the collected data. In order to analyze the difference of wettability and surface roughness according to implant surface treatment method. The statistical significance was tested with the confidence level of 95%. Pearson's correlation coefficient was used to evaluate the correlation of surface roughness and wettability. Results: The difference of surface roughness was statistically significant in the order of Group C ($1.69{\pm}0.26$), Group D ($1.58{\pm}0.16$), Group B ($0.78{\pm}0.14$) Group A ($0.18{\pm}0.05$). The wettability has also a statistically significant difference, which was in the order of group B ($17.70{\pm}2.66$), Group C ($27.86{\pm}4.52$), Group D ($66.28{\pm}3.70$) Group A ($70.52{\pm}8.00$). There was no difference in wettability with the passage of time. Conclusions: 1. The surface roughness was high in the order of RBM, CMP, Anodized, Machined group (P<.05). 2. The wettability was high in the order of Anodized, RBM, CMP, Machined group (P<.05). 3. There was no statistical significance in the correlation of surface roughness and wettability.

Effect of various casting alloys and abutment composition on the marginal accuracy of bar-type retainer (합금의 종류와 지대주 성분이 바형 유지 장치의 변연 적합도에 미치는 영향)

  • Lee, Yun-Hui;Song, Young-Gyun;Lee, Joon-Seok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • Purpose: The object of this study was to determine if the low-priced alloy and metal UCLA abutment could be available for manufacturing bar-retained framework of implant prosthesis. Materials and methods: Bar structure was classified into 4 groups, The specimen of group 1 and 2 were based on casting high noble metal alloys and noble metal alloys with gold UCLA abutment. The specimen of group 3 and 4 were based on casting noble metal alloys and base metal alloys with metal UCLA abutment. Cast bar structure was installed in an acrylic resin model and only the screw on the hexed abutment side was tightened to 20 Ncm. On the opposite side, vertical discrepancy was measured with stereo microscope from front, back, and lateral side of the implant-abutment interface. One-way ANOVA was performed to analyze the marginal fit discrepancy. Results: One-way ANOVA test showed significant differences among all groups ($P$<.05) except for Group 1 and 3. Among them, difference between Group 1 and 2 was noticeable. Measured vertical discrepancies were all below $70{\mu}m$ except to Group 2. Conclusion: Base metal alloy and metal UCLA abutment could be used as an alternative to high-priced gold alloy for implant bar-retained framework.

Histologic findings of three-wall intrabony defects around dental implants using different grafting materials in beagle dogs (수종의 골이식재를 이용한 성견의 임플란트 주위 3면 골내낭의 조직학적 관찰)

  • Moon, Hee-Il;Moon, Sang-Kwon;Shim, Chang-sung;Shim, Jung-Sung;Lee, Yong-Keun;Cho, Kyu-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.33 no.3
    • /
    • pp.439-455
    • /
    • 2003
  • 연구목적 : SLA surface dental implant 주위의 3면 골내낭에서 xenogeneic demineralized bone matric putty, porous ${\beta}$-tri-calcium phosphate, 새로이 개발된 non-crystalline calcium phosphate glass를 사용한 치료를 조직학적으로 비교 평가하기 위한 것이다. 연구방법 : 실험동물로는 15개월에서 18개월 사이의 12kg에서 15kg 정도되는 성견을 사용하였다. 20개의 SLA surface implant가 사용되었으며, 성견 하악의 양측에 각각 2개씩 사용되었다. 임플란트 식립전에, 각각의 임플란트 근심면에 straight fissure bur를 이용하여 표준화된 3면 골내앙(근원심 5mm ${\times}$협설 3mm ${\times}$깊이 3mm)을 형성하였다. 형성된 골 결손부에는 demineralized bone matrix putty, porous ${\beta}$-tri-calcium phosphate, non-crystalline calcium phosphate glass를 넣은 것을 각각 실험군으로, 이식재를 넣지 않은 것을 대조군으로 사용하였다. 8주 후에 실험 동물을 희생시키고 조직학적 관찰을 하였다. 결과 : 조직학적 소견상 임플란트 주위에 급성 염증 소견은 보이지 않았으며, non-crystalline calcium phosphate glass은 매우 적은량의 신생골을, ${\beta}$-TCP을 이용한 골내낭에서는 약간의 기저부에서 유래된 신생골이 관찰된다. ${\beta}$-TCP granules 가운데로 상당량의 측면의 골에서 유래된 신생골 형성이 보인다. xenogeneic DBM putty에서는 많은 량의 신생골이 기저부에 형성된 것을 볼수 있으나 대조군과의 차이는 크지 않다. 이식재의 종류와 상관없이 흡수되지 않은 이식재를 임플란트 주위에서 관찰할 수 있었다. 골내낭 안의 이식재들은 모두 connective tissue로 둘러 싸여 있었다. 모든 실험군에서 이식재에서 기인한 신생골 형성과 임플란트 표면에 신생 골유착의 조직학적 증거는 발견되지 않았다.

Dental implant bottom-up cost analysis (치과 임플란트 상향식(bottom-up) 원가산정)

  • Kim, Min-Young;Choi, Ha-Na;Shin, Ho-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.18-26
    • /
    • 2014
  • Purpose: The purpose of this study was to estimate the cost of dental implant using the bottom-up approach with the current data from dental clinics. Materials and methods: In this study, direct and indirect costs required for each treatment were calculated using the bottom-up approach. In the bottom-up costing, the average monthly total cost of dental clinic includes labor and material costs, administrative expenses, medical malpractice costs, and opportunity costs of invested capital. For the dental implant cost components, those include direct costs (labor costs, laboratory costs, material costs, depreciation or other operating costs), indirect costs (administrative costs), and the opportunity costs of investment for dental clinic. Results: Dental implant costs of metal crown, porcelain crown and over-denture were 1,449,000 won, 1,583,000 won, and 2,471,000 won respectively. The proportion of cost components was as follows. The labor cost were 50%, and material, administrative and other cost were 33%, 15% and 2%, respectively. For direct, indirect and investment cost, the ratio were 83%, 15% and 2%, respectively. Conclusion: The labor costs were evaluated to comprise largest proportion (about 50%, 730,000 won). Dental implant cost using Bottom-up costing was 1,450,000 won for metal crown and 1,580,000 won for porcelain crown.

Biocompatibility and Surface Characteristics of (Si,Mn)-HA Coated Ti-Alloy by Plasma Electrolytic Oxidation (PEO법으로 (Si,Mn)-HA 코팅된 치과 임플란트용 Ti 합금의 생체적합성 및 표면특성)

  • Gang, Jeong-In;Son, Mi-Gyeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.83-83
    • /
    • 2017
  • 생체재료의 표면은 이식과 동시에 생체계면의 역할을 하게 되어, 일련의 생물학적 반응이 시작되고 진행되는 중요한 장소가 된다. 초기에 생체계면에서 일어나는 단백질 흡착이나 염증반응을 비롯한 생물학적 반응들은 궁극적으로 임플란트의 성패를 좌우할 만큼 중요하다. 골융합을 개선하기 위한 다른 방법으로 생체불활성의 타이타늄 (Ti)과 골조직의 능동적인 반응을 이루기 위해 생체활성 표면을 부여함으로서 계면에서의 골형성 반응을 증진시키는 방법이 이용된다. 생체불활성의 Ti과 Ti합금은 골조직과 직접적인 결합을 이루지 못하므로, 골조직과의 반응을 향상하기 위해 여러 종류의 생체활성 재료를 코팅하는 방법이 연구되어 왔고, 이 중 생체의 변화와 가장 유사한 하이드록시아파타이트 코팅이 가장 대중적인 방법으로 사용되었으며 이는 초기 골형성을 촉진하는 것으로 알려졌다. 치과용 임플란트의 표면형상과 화학조성이 골 융합에 영향을 미치는 가장 중요한 인자이므로 최근의 연구동향은 이들 두 가지 표면특성을 결합함으로서 결과적으로 최적의 골세포반응을 유도하고, 골융합 후 골조직과의 micromechanical interlocking에 의해 임플란트의 안정성에 중요한 역할을 하는 마이크론 단위의 표면조도와 표면 구조를 유지하면서, 부가적으로 골 조직 반응을 능동적으로 개선할 수 있는 생체활성 성분을 부여하여 골 융합에 상승효과를 이루기 위한 표면처리법에 관해 많은 연구가 요구되어지고 있다. 따라서 골을 구하는 원소인 망간과 실리콘으로 치환된 하이드록시아파타이트를 플라즈마 전해 산화법으로 코팅하여 세포와 잘 결합할 수 있는 표면을 제공함으로써 골 융합과 치유기간을 단축시킬 수 있을 것으로 사료된다. 실험방법은 시편은 치과 임플란트 제작 합금인 Ti-6Al-4V ELI disk (grade 5, Timet Co., USA; diameter, 10 mm, thickness, 3 mm)이며, calcium acetate monohydrate, calcium glycerophosphate, manganese(II) acetate tetrahydrate, sodium metasilicate을 설계조건에 따라 혼합 제조된 전해질 용액을 이용하여 플라즈마 전해 산화법으로 표면 코팅을 실시하였다. 각 시편의 플라즈마 전해시 전압은 280V로 인가하였고, 전류밀도는 70mA로 정전류를 공급하여 해당 인가전압 도달 후 3분 동안 정전압 방식을 유지하였다. 코팅된 피막 표면을 주사전자현미경과 X-선 회절분석을 통하여 미세구조 및 결정상을 관찰하였다. 또한 코팅된 표면의 생체활성 평가는 정량적으로 평가하기 위해 동전위시험과 AC 임피던스를 통하여 시행하였다. 분극거동을 확인하기 위해 potentiostat (Model PARSTAT 2273, EG&G, USA)을 이용하여 구강 내 환경과 유사한 $36.5{\pm}1^{\circ}C$의 0.9 wt.% NaCl에서 실시하였다. 전기화학적 부식 거동은 potentiodynamic 방법으로 조사하였고 인가전위는 -1500 mV에서 2000 mV까지 분당 1.67 mV/min 의 주사속도로 인가하여 시험을 수행하였다. 임피던스 측정은 potentiostat (Model PARSTAT 2273, EG&G, USA)을 이용하였으며, 측정에 사용한 주파수 영역은 10mHz ~ 100kHz 까지의 범위로 하여 조사하였고 ZSimWin(Princeton applied Research, USA) 소프트웨어를 사용하여 용액의 저항, 분극 저항 값을 산출하였다. 망간의 함량이 증가할수록 불규칙한 기공을 보였으며, 실리콘은 $TiO_2$ 산화막 형성을 저해하는 경향을 확인할 수 있었다. 단독으로 표면을 처리한 경우보다 두 가지 원소를 이용해 복합 표면처리를 시행한 경우가 내식성이 좋아 임플란트과의 골 유착에 긍정적인 영향을 미칠 것으로 사료된다.

  • PDF

Clinical evaluation of the removable partial dentures with implant fixed prostheses (임플란트 고정성 보철물을 이용한 가철성 국소의치의 합병증에 관한 임상적 평가)

  • Kang, Soo-Hyun;Kim, Seong-Kyun;Heo, Seong-Joo;Koak, Jai-Young;Lee, Joo-Hee;Park, Ji-Man
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.239-245
    • /
    • 2016
  • Purpose: The purpose of this study was to identify clinical complications in removable partial denture (RPD) with implant-supported surveyed prostheses, and to analyze the factors associated with the complications such as location of the implant, splinting adjacent prostheses, the type of retentive clasps, Kennedy classification, and opposing dentition. Materials and Methods: A retrospective clinical study was carried out for 11 patients (7 male, 4 female), mean age of 67.5, who received RPD with Implant-supported surveyed prostheses between 2000 and 2016. The mechanical complications of 11 RPDs and 37 supporting implant prostheses and the state of natural teeth and peripheral soft tissue were examined. Then the factors associated with the complications were analyzed. Results: The average of 3.4 implant-supported prostheses were used for each RPD. Complications found during the follow-up period of an average of 42.1 months were in order of dislodgement of temporary cement-retained prostheses, opposing tooth fracture/mobility, screw fracture/loosening, clasp loosening, veneer porcelain fracture, marginal bone resorption and mobility of implant, artificial tooth fracture. Complications occurred more frequently in anterior region compared to posterior region, non-splinted prostheses compared to splinted prostheses, surveyed prostheses applied by wrought wire clasp compared to other clasps, and natural dentition compared to other removable prostheses as opposing dentition. There were no significant differences in complications according to the Kennedy classification. Conclusion: All implant-assisted RPD functioned successfully throughout the follow-up. However, further clinical studies are necessary because the clinical evidences are still not enough to guarantee the satisfactory prognosis of implant-assisted RPD for long-term result.

Comparison of marginal and internal fit of zirconia abutments with titanium abutments in internal hexagonal implants (내부육각 연결형 임플란트에서 지르코니아 지대주와 티타늄 지대주의 변연 및 내면 적합도의 비교)

  • Kim, Young-Ho;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.93-102
    • /
    • 2016
  • Purpose: The aim of this study was to evaluate the fit accuracy of two zirconia and titanium abutments in internal hexagonal implants. Materials and methods: One titanium abutment and two zirconia abutments were tested in internal hexagonal implants (TSV, Zimmer). Prefabricated zirconia abutments (ZirAce, Acucera) and customized zirconia abutments milled by the Zirkonzahn system (Zirkonzahn Max, Zirkonzahn) were selected and prefabricated titanium abutments (Hex-Lock, Zimmer) were used as a control. Eight abutments per group were connected to implants with 30 Ncm torque. The marginal gaps at abutment-implant interface, the internal gaps at internal hex, vertical and horizontal gaps between screws and screw seats in abutments were measured after sectioning the embedded specimens using a scanning electron microscope. Data analysis included one-way analysis of variance and the Scheffe test (n=16, ${\alpha}=0.05$). Results: The mean marginal gap of customized zirconia abutment was higher than those of two prefabricated zirconia and titanium abutments. The internal gaps at internal hex showed no significant differences between customized and prefabricated abutments and were higher than those of prefabricated titanium abutments. The mean vertical and horizontal gaps at screw in prefabricated zirconia abutment were higher than those of prefabricated titanium abutment. In the case of customized zirconia abutment, the mean horizontal gap at screw was higher than those of both the prefabricated zirconia and the titanium abutment but the mean vertical gap was not even measureable. The screw seats were clearly formed but did not match with abutment screws in prefabricated zirconia abutments. They were not, however, precisely formed in the case of customized zirconia abutments. Conclusion: Within the limitations of this study, the prefabricated titanium abutments showed better fit than the zirconia abutments, regardless of customized or prefabricated. Also, the customized zirconia abutments showed significantly higher marginal gaps and the fit was less accurate between screws and screw seats than the prefabricated abutments, titanium and zirconia.

A study on the compatibility of implant drivers (임플란트 드라이버의 호환성에 대한 연구)

  • Kim, Min-Soo;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.34-41
    • /
    • 2014
  • Purpose: In this study, the diameter of each implant driver was measured and compared to find out the compatibility of implant drivers. Materials and methods: Drivers from 12 implant systems being used in Dankook University Dental Hospital were included in this study. The shapes of the implant drivers were segregated, and the effective length and the diameter of upper, middle, lower part of driver tips were measured (n=10). The measured data were mathematically analyzed for its compatibility. Results: A driver with the smallest diameter (1.17 mm) had the highest compatibility at the upper part of driver tip. This driver could be used for a bigger driver up to 1.35 mm in diameter. There were several driver groups which had the same diameter so as to be interchangeable each other. In the middle part, the smallest diameter measured was 1.2 mm and this was able to replace a driver up to 1.40 mm diameter. Since the diameter generally became thicker from upper part (the tip of driver) to the lower part (the shank of driver), some drivers with bigger diameter at the upper part so which was failed to show any compatibility became compatible with a driver which had smaller diameter at the upper part but wider in the middle part. The compatibility of torx shape drivers were affected by the inner diameter of the drivers not only by the outer diameter. Furthermore, the inner diameter of torx drivers decided the compatibility between torx and hex drivers. Conclusion: From the study it was found that compatibility in drivers existed among certain implant systems and to check its compatibility the diameter at a certain effective length should be measured. However, there has been not enough studies about long-term use of compatible drivers, so effects of using compatible drivers on drivers and implants are unknown. Therefore, usage in inevitable cases only is recommended and further study is needed.

Influence of implant diameter and length changes on initial stability (임플란트의 직경과 길이 변화가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Cho, Uk;Yun, Mi-Jung;Jeong, Chang-Mo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Statements of problem: Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the actual effect of dimensional change in implant geometry on initial stability. Purpose: The purpose of the current study was to investigate the influence of diameter and length changes on initial stability of implants. Material and methods: Four types of dummy bone (D1, D2, D3 and D4) consisted of cortical and cancellous layers with different thickness were simulated. Implants which had similar surface area to each other ($3.5{\times}13.0-mm$, $4.0{\times}11.5-mm$, $4.5{\times}10.0-mm$, $5.0{\times}8.5-mm$) were inserted in dummy bones. Implant stability as a function of peak insertion torque and resonance frequency values were recorded for each implant. Results: 1. Bone quality was a major influential factor to achieve initial stability (P <.05). 2. In D1, D2 and D3 dummy bones, implant stability quotient values were not significantly different to each other (P >.05), however insertion torques were increased with wider and shorter implants (P <.05). 3. In D4 dummy bone, implant stability quotient values and insertion torques were decreased with wider and shorter implants (P <.05). Conclusion: From a point of view of initial stability, it is suggested that use of wide and short implant may be helpful in avoiding bone augmentation procedures in area of adequate bone quality.

Effect of Implant Types and Bone Resorption on the Fatigue Life and Fracture Characteristics of Dental Implants (임플란트 형태와 골흡수가 임플란트 피로 수명 및 파절 특성에 미치는 효과에 관한 연구)

  • Won, Ho-Yeon;Choi, Yu-Sung;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.121-143
    • /
    • 2010
  • To investigate the effect of implant types and bone resorption on the fracture characteristics. 4 types of Osstem$^{(R)}$Implant were chosen and classified into external parallel, internal parallel, external taper, internal taper groups. Finite elements analysis was conducted with ANSYS Multi Physics software. Fatigue fracture test was performed by connecting the mold to the dynamic load fatigue testing machine with maximum load of 600N and minimum load of 60N. The entire fatigue test was performed with frequency of 14Hz and fractured specimens were observed with Hitachi S-3000 H scanning electron microscope. The results were as follows: 1. In the fatigue test of 2 mm exposed implants group, Tapered type and external connected type had higher fatigue life. 2. In the fatigue test of 4 mm exposed implants group, Parallel type and external connected types had higher fatigue life. 3. The fracture patterns of all 4 mm exposed implant system appeared transversely near the dead space of the fixture. With a exposing level of 2 mm, all internally connected implant systems were fractured transversely at the platform of fixture facing the abutment. but externally connected ones were fractured at the fillet of abutment body and hexa of fixture or near the dead space of the fixture. 4. Many fatigue striations were observed near the crack initiation and propagation sites. The cleavage with facet or dimple fractures appeared at the final fracture sites. 5. Effective stress of buccal site with compressive stress is higher than that of lingual site with tensile stress, and effective stress acting on the fixture is higher than that of the abutment screw. Also, maximum effective stress acting on the parallel type fixtures is higher. It is careful to use the internal type implant system in posterior area.