• Title/Summary/Keyword: 임플란트 식립

Search Result 494, Processing Time 0.025 seconds

Three-dimensional finite element analysis according to the insertion depth of an immediately loaded implant in the anterior maxilla (상악 전치부 즉시하중 임플란트의 식립 깊이에 따른 삼차원 유한요소 분석)

  • Park, Cheol-Woo;Kim, Sung-Hun;Yeo, In-Sung;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.105-113
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the effects of the insertion depth of an immediately loaded implant on the stress distribution of the surrounding bone and the micromovement of the implant using the three-dimensional finite element analysis. Materials and methods: A total of five bone models were constructed such that the implant platform was positioned at the levels of 0.00 mm, 0.25 mm, 0.50 mm, 0.75 mm, and 1.00 mm depth from the crest of the cortical bone. A frictional coefficient of 0.3 and the insertion torque of 35 Ncm were simulated on the interface between the implant and surrounding bone. A static load of 178 N was applied to the provisional prosthesis with a vertical load in the axial direction and an oblique load at $30^{\circ}$ with respect to the central axis of the implant, then a finite element analysis was performed. Results: The implant insertion depth significantly affected the stress distribution on the surrounding bone. The largest micromovement value of the implant was $39.34{\mu}m$. The oblique load contributed significantly to the stress distribution and micromovement in comparison to the vertical load. Conclusion: Increasing the implant insertion depth was advantageous in dispersing the concentrated stress in the cortical bone and did not significantly affect the micromovement associated with early osseointegration failure.

Periimplant bone change after alveolar ridge preservation: radiographic retrospective study (발치와 치조제 보존술 후 식립한 임플란트 주위 골 변화: 후향적 방사선학적 분석)

  • Shim, Da-Eun;Pang, Eun-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.281-290
    • /
    • 2021
  • Purpose. The aim of this study is to evaluate bone change around the implant in patients who underwent alveolar ridge preservation for implantation in the posterior teeth using radiographic data measuring changes of mesial, distal crestal bone level according to post-implantation, post-final prosthesis delivery and follow-up periods. Materials and methods. In total, 36 implants were placed in 32 patients. The mesial and distal crestal bone level of all the areas where alveolar ridge preservation was performed uses panoramic images taken post-implantation, post-final prosthesis delivery, and follow-up period each was measured and evaluated as a vertical value. The following factors were analyzed: associations between changes of crestal bone level and factors (e.g., age, sex, systemic diseases, dentist, implant location, tooth, bone type, membrane). The statistical analysis was performed using the mean, standard deviation and independent t-test, paired t-test (P < .05). Results. Analysis of crestal bone level differences between periods shows statistically significant differences (P < .05). There was no statistically significant difference when the changes of crestal bone level between post-implantation, post-final prosthesis delivery and follow-up periods were correlated with each factors. Conclusion. After alveolar ridge preservation, bone around the implant remained stable during the maintenance period without being affected by the patient and surgical factors, and alveolar ridge preservation is considered a clinically usable procedure.

Factors affecting the survival of implants: a long-term retrospective study (임플란트의 생존에 영향을 미치는 요인에 대한 장기간의 후향적 연구)

  • Song, Susanna;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.10-19
    • /
    • 2015
  • Purpose: The aim of the present study was to evaluate the long-term survival of implants retrospectively and determine the risk factors associated with implant failure. Materials and Methods: Of all implants that were placed at the Department of Periodontology of the Dental Hospital of Gangneung-Wonju National University from January 1998 to December 2012, 2265 implants that were followed up until June 2013 were included in this study. Data were collected from clinical and radiographic examinations from previous visits. The information gathered included gender, age, smoking status, implant diameter, implant length, surface of implant, location of implant within the dental arch, surgical techniques and existence of complications. Results: The survival rate before loading was 98.9%. The cumulative survival rate after 5 years of loading was 97.2%, and after 15 years of loading was 95.2%. In a simple logistic regression analysis, gender (P = 0.016), smoking status (P = 0.001), location of implant (P = 0.020) and existence of complications (P = 0.002) were statistically associated with implant failure and included in the multiple regression analysis. As a result of multiple logistic regression analysis, the variables statistically associated with implant failure (P < 0.05) were smoking status (P = 0.049) and existence of complications (P < 0.001). Conclusion: The cumulative survival rate of dental implants after 15 years of loading was 95.2% and that the variables statistically associated with implant failure were smoking status and existence of complications.

A systematic review of the survival rate on short implants (짧은 임플란트의 생존율에 관한 고찰)

  • Lee, Eun-Jeong;Kim, Won;Choi, Ji-Young;Kim, Seong-Mi;Oh, Nam-Sik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.457-462
    • /
    • 2009
  • Purpose: The objective of this systematic review was to obtain the comprehensive survival rates of short implants. Then it was examined that whether treatment using short implants has favorable results. Methods: A MEDLINE search was performed, the data obtained from many articles about length, diameter, site of placement, surface treatment and prosthetic design were analyzed. Results and discussion: The data obtained from many articles were analyzed, and it was found that the survival rate of short implants was 95.87%, short implants has similar outcomes to those reported for standard implants. On the other hand, in the comparison the survival rate of 3 groups divided by the diameter of implants under 4 mm, 4-5 mm, and above 5 mm, a statistically significant difference was detected in under 4mm group. In implant group with 6-7 mm length, a group with 5-6 mm diameter has survival rate of 97.01%, groups with 3.1-4.8 mm diameter has survival rate of 92.96%, which was statistically significantly different. In the result of surface feature, the roughed surface groups of short implant showed a higher survival rate by approximately 6.3% than machined surface group. In the result of prosthetic design, survival rate of short implant was considerably lower for the single implant crown group (94.3%) than splinting group (99.4%).

Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery (폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가)

  • Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.306-312
    • /
    • 2020
  • Purpose: The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month post-placement. Materials and methods: A total of 12 implants were assessed in 12 patients for the sites where 0.5 - 1.5 mm labial bone was covering the implants, using CBCT. Results: A statistically significant preservation of crestal bone was observed in the narrow-diameter implants. Conclusion: Guided flapless implant surgery may be important in preventing bone loss around the narrow-diameter implants that are placed in narrow alveolar ridges.

Radiologic evaluation and survival rate of taper-straight designed implant with SLA surface: A 1-year follow-up retrospective study (SLA surface를 가진 taper straight designed implant의 방사선학적 평가와 생존율: 1년 추적 관찰을 통한 후향적 연구)

  • Kim, Jee Eun;Kim, Ye Seul;Kim, Ok-Su
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.4
    • /
    • pp.405-414
    • /
    • 2021
  • Purpose. This study was conducted to evaluate clinical usefulness by evaluating the marginal bone resorption and survival rate of an implant with a taper straight type SLA surface domestically available on the market recently. Materials and methods. 40 implants satisfying the including criteria were observed for one year of 125 implants of 83 adult men and women who had KISPLANT® implanted from August 2016 to December 2019 at the Department of Periodontology, Chonnam National University Dental Hospital. The marginal bone level was measured on periapical radiographs taken initially and 1 year later and we analyzed implant survival and success rates. A t-test was used for the analysis of the association between the marginal bone resorption and the severity of periodontitis, supportive periodontal therapy, the inserted site, the cause of extraction, immediate placement, and systemic disease. Results. After 1 year of loading, the mesial bone resorption was 0.74 ± 1.07 mm, and the distal bone resorption was 0.53 ± 1.04 mm. The marginal bone resorption of 2 mm or more occurred at 3 implants out of 40 implants after 1 year, so the success rate of implant was 92.5% and survival rate was 100%. There was a significant difference in mesial marginal bone resorption according to the inserted site and no significant differences were found between marginal bone resorption and the other factors. Conclusion. As a result of marginal bone resorption, success rate, and survival rate in this study, we found little marginal bone resorption and high survival and success rate. It can be concluded that they represent excellent clinical results.

The influence of magnet on tissue healing after immediate implantation in fresh extraction sites in dogs (성견에서 발치 후 즉시 식립 임플란트에 설치한 자석이 주위 조직에 미치는 영향)

  • Yu, Seok-Min;Cho, In-Ho;Shin, Soo-Yeon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.435-444
    • /
    • 2009
  • Statement of problem: The clinical use of electric and electomagnetic fields for fracture healing applications began in the early 1970s. Since then, several technologies have been developed and shown to promote healing of fractures. Developments of these devices have been aided in recent years by basic research and several well controlled clinical trials not only in the medical field but in dentistry. Purpose: The purpose of this study was to compare alveolar bone reduction following immediate implantation using implants onto which magnets were attached in fresh extracted sockets. Material and methods: Four mongrel dogs were involved. Full buccal and lingual mucoperiosteal flaps were elevated and third and fourth premolars of the mandible were removed. Implants with magnets and implants without magnets were installed in the fresh extracted sockets and after 3 months of healing the animals were sacrificed. The mandibles were dissected and each implant sites were sampled and processed for histological examination. Results: The marginal gaps that were present between the implant and walls of the sockets at the implantation stage disappeared in both groups as a result of bone fill and resorption of the bone crest. The buccal bone crests were located apical of its lingual counterparts. At the 12 week interval the mean of marginal bone resorption in the control group was significantly higher than that of the magnet group. The majority of specimens in magnet group presented early bone formation and less resorption of the buccal marginal bone compared to the control group. Conclusion: Within the limitations of this study, it could be concluded that implants with magnets attached in the early stages of implantation may provide more favorable conditions for early bone formation and reduce resorption and remodeling of marginal bone.

Mandibular implant overdenture using milled bar attachment on implants with unfavorable fixture angulation: A case report (불량한 식립 방향을 갖는 임플란트를 이용한 하악 Milled Bar 임플란트 피개의치수복 증례)

  • Seo, Yong-Ho;Jeon, Young-Chan;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.4
    • /
    • pp.401-406
    • /
    • 2016
  • Implant overdenture exhibits higher retention, masticatory function, and patient's satisfaction compared to conventional dentures. Particularly, in treatment of severe alveolar bone resorption, implant overdenture can be considered as the first treatment option. The types of attachments used for implant overdenture can be classified into solitary type, which implants are not connected to each other, and bar type in which implants are connected. In the case of solitary type commonly used in clinical practice, parallel relationship is important. When it is not established, there is a higher risk of attachment wear, retention loss, and frequent visits for maintenance. In this case, satisfactory results have been obtained with implant overdentures using milled bar on two unparallel implants placed on the mandible.

Influence of Implant Designs on Initial Stability (임플란트의 형태가 초기 안정성에 미치는 영향)

  • Cho, Jae-Myoung;Kim, Chang-Seop;Yun, Mi-Jung;Jeong, Chang-Mo;Seo, Seung-U
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.1
    • /
    • pp.47-57
    • /
    • 2010
  • An undisturbed healing process without micromotion at the implant-bone interface is essential for achievement of osseointegration of dental implant. Therefore, initial stability was advocated as prerequisite for successful clinical outcome. Adequate bone quality and quantity were important to achieve initial stability and to prevent early failures. However there were few published data available regarding the effect of design change in implant geometry on initial stability of the implants. The purpose of the current study was to assess the initial stability of various designs of implants when placed into artificial bone materials of varying qualities and shapes of insertion holes. Within the scope of this study, the following results were drawn. Bone quality was major importance to achieve initial stability. Initial stability was higher on GS II which had additional design feature of double thread. With a tapered design of implant such as GS III showed a higher initial stability than straight one. An insertion hole with the similar shape of implant would lead to reduce a compression force on cortical bone and enhance a bone anchorage on cancellous bone.