• Title/Summary/Keyword: 임플란트의 선택

Search Result 97, Processing Time 0.027 seconds

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

Comparison of Expectation and Satisfaction of Implant Patients in Pre-post Implant Therapy (임플란트 시술환자 시술 전·후의 기대와 만족도 비교)

  • Han, Ji-Hyoung;Kim, Ki-Eun
    • Journal of dental hygiene science
    • /
    • v.11 no.2
    • /
    • pp.121-127
    • /
    • 2011
  • This study was conducted to improve patients satisfaction by comparing patients expectation prior to the implant therapy to patient satisfaction after the implant therapy. The data of 158 patients with dental implant in Seoul, Gyeonggi-Do and Cheonan city was obtained. The results are as follows : 1. 40.5% of patients placed one implant and 36.1 % of patients answered that the average cost for each implant is from 1,500,000 to 2,000,000won. 23.4% of them answered they decided to have implant because no tooth preparation is required. 2. Overall, the expectation level for implant therapy in general properties, women showed higher level of expectation than men. Especially, 'Implant has a longer life than other denture' showed significant difference between women(4.29) and men(3.87). Expectation by age, 'Implant has similar color and shape' was found the highest in age 20(4.38). Satisfaction by general properties, 'No tooth preparation required' was found the highest in age 20(4.57) and was statistically significant(p<.002). 3. Comparing patients' expectation prior to implant therapy to satisfaction afterward, 'Implant prevents jawbone resorption and keeps facial appearance' showed 3.7 of expectation but satisfaction was found increased to 3.87(p=.020). No tooth preparation required' was found 3.95 in expectation prior to implant therapy but after therapy it was found 4.23 in satisfaction (p<.001). 4. Overall satisfaction in implant therapy was found 4.25, recommendation to other patients was found 4.18 and repurchase was found 4.17.

Discussion of Neurologic Factor Influencing on Chewing Ability of Implant (임플란트 저작능에 영향을 주는 신경학적 원인에 대한 고찰)

  • Kim, Tae-Seon;Yoon, Jun-Ho;Kim, Sung-Hoi;Kim, Jee-Hwan;Shim, June-Sung;Lee, Jae-Hoon;Moon, Hong-Suk;Park, Young-Bum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.269-276
    • /
    • 2012
  • Many researches have been published about the numerous factors related to the chewing ability of implant prosthesis. Most respective studies have concluded that the chewing ability of implant prosthesis is mostly fine compared to other type of prosthesis. However, some patients are not satisfied with their chewing ability of implant prosthesis. Therefore the neurologic factor, one of the factors related to dissatisfaction of chewing ability was reviewed in this study to understand the mechanism of action of mastication. Data was searched using the keywords; 'implant chewing ability, masticatory ability' in Pubmed database and reviewed. Definitions of chewing ability, factors of chewing ability are reviewed and the neurologic factor, one of the factors influencing on chewing ability, is reviewed. Mechanoreceptor of Periodontal ligament(PDL) is providing the mastication information to brainstem. Due to the absence of mechanoreceptions of PDL in implant, masticatory ability is decreased especially when chewing hard food. Masticatory muscles and mechanoreceptor in TMD may compensate the lack of mechanoreceptor of PDL in implants. Furthermore sensitivity of nerve fiber around peri-implant tissues may support the mechanoreception and sensory reaction in the implant mastication. However, further studies should be conducted to prove the relationships between neurologic factors and mastication.

Effect of open proximal contact on adjacent tooth and implant (개방된 인접면 접촉이 인접자연치와 임플란트에 미치는 영향)

  • Moon, Sohyun;Kim, Gwangyun;Cho, Seonghun;Song, Joohun;Kim, Hee-Jung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate how open contacts impact the natural teeth and dental implant prostheses. Materials and Methods: Following criteria were used to select 20 implant crowns with open proximal contacts as the experimental group (Group A): the restorations were delivered in Chosun University Dental Hospital between 2008 and 2018, the restorations are in the posterior region, opposing teeth are fixed dental prostheses, neighboring teeth are sound natural teeth, the patient had been on the maintenance program for at least 3 years. Another 20 implant crowns with closed proximal contacts were selected as the control group (Group B) using the same criteria. Between the two groups, dental caries and food impaction of the neighboring natural teeth and marginal bone-loss of the implants were compared and evaluated. Results: There was no statistically significant difference between Group A and Group B in the occurrence rates of dental caries, food impaction, and marginal bone-loss. The amount of marginal bone-loss, however, revealed statistically significant differences between the two groups, with Group A showing 0.80 ± 0.39 mm loss and Group B showing 1.1 ± 0.43 mm loss. Conclusion: Implant prostheses with open contacts could be clinically considered in select cases as such restorations revealed no harmful effects on neighboring teeth and implant restorations within the perimeters of this study.

A Study on The Factors Influencing the Decision to Get Implant Treatment at Dental Clinic (치과의원에서 임플란트 치료 결정에 영향을 미치는 요인에 관한 연구)

  • Oh, Hye-Young;Jin, Ki-Nam
    • Journal of dental hygiene science
    • /
    • v.12 no.2
    • /
    • pp.85-91
    • /
    • 2012
  • The purpose of this study was to examine the factors influencing the decision to get implant treatment at dental clinic. The subjects in this study were 321 patients at dental hospitals and clinics. Andersen model in which predisposing variables, enabling variables and need variables were suggested as independent variables was used. The implant decision making was selected as a dependent variable in the model. Using logistic regression analysis, we found statistically significant effects of three independent variables: 1) class, 2) satisfaction with the facility; 3) familiarity with others received implant treatment. Those with the middle or high class background were more likely to take implant treatment. Those who were satisfied with clinic facility were more likely to take implant treatment. Those who were familiar with others received implant treatment were more likely to take implant treatment. This result implies the importance of opinion of others were received the same treatment. Hence viral marketing effort is required even in dental care field.

Optimization of orthodontic microimplant thread design (교정용 마이크로 임플란트의 나사산 디자인 최적화)

  • Kim, Kwang-Duk;Yu, Won-Jae;Park, Hyo-Sang;Kyung, Hee-Moon;Kwon, Oh-Won
    • The korean journal of orthodontics
    • /
    • v.41 no.1
    • /
    • pp.25-35
    • /
    • 2011
  • Objective: The purpose of this study was to optimize the thread pattern of orthodontic microimplants. Methods: In search of an optimal thread for orthodontic microimplants, an objective function stability quotient (SQ) was built and solved which will help increase the stability and torsional strength of microimplants while reducing the bone damage during insertion. Selecting the AbsoAnchor SH1312-7 microimplant (Dentos Inc., Daegu, Korea) as a control, and using the thread height (h) and pitch (p) as design parameters, new thread designs with optimal combination of hand p combination were developed. Design soundness of the new threads were examined through insertion strain analyses using 3D finite element simulation, torque test, and clinical test. Results: Solving the function SQ, four new models with optimized thread designs were developed (h200p6, h225p7, h250p8, and h275p8). Finite element analysis has shown that these new designs may cause less bone damage during insertion. The torsional strength of two models h200p6 and h225p7 were significantly higher than the control. On the other hand, clinical test of models h200p6 and h250p8 had similar success rates when compared to the control. Conclusion: Overall, the new thread designs exhibited better performance than the control which indicated that the optimization methodology may be a useful tool when designing orthodontic microimplant threads.

The effect of horizontal microgap location on the bone loss around 2-piece implants (2-piece 임플란트에서 미세 간극의 수평적 위치 변화에 따른 골 소실 비교 연구)

  • Kim, Jae-Il;Lee, Yong-Moo;Yang, Byoung-Keon;Ku, Young;Chung, Chong-Pyoung;Han, Soo-Boo;Rhyu, In-Chul
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.1
    • /
    • pp.83-91
    • /
    • 2004
  • 2-piece 임플란트에서는 초기 치유 기간 동안 0.9-1.6mm의 골 소실이 일어나는데 2-piece 임플란트의 미세 간극과 그에 따른 생물학적 폭경의 형성이 중요한 원인이다. 최근 수직적으로 미세 간극의 위치를 변화시킴으로 골 소실의 양을 줄일 수 있다는 보고가 있다. 이번 실험의 목적은 미세 간극의 수평적 위치 변화에 따른 골 소실의 양을 비교하는데 있다. 하악에서 인접하여 최소 2개의 임플란트를 식립할 수 있는 7 무치악 부위에 총 15개의 Osseotitie XP 4/5를 식립하였다. 이때 임플란트의 상연이 주위 치조골과 일치하게 식립하였고 무작위로 선택하여 한 그룹(W군)에서는 wide diameter healing abutment를 연결하였고 다른 한 그룹(S 군)에서는 standard diameter healing abutment를 연결하였다. 3개월의 치유 기간후 보철 과정을 시작하였으며 이 때 healing abutment와 같은 크기의 prosthetic component를 이용하였다. 임플란트 식립 직후, 3개월의 치유 기간이 지난 보철 직전(Interval I)에, 보철 과정 직후(Interval II)에 각각 치근단 방사선 사진을 찍어 각 단계에서의 골 소실 양을 비교하였다. W 군의 경우 골 소실의 양이 Interval I에서 $1.60{\pm}0.78$, Interval I+II에서 $2.36{\pm}0.29$이었고 S 군에서는 Interval I에서 $1.5810{\pm}0.3030$, Interval I+II에서는 $1.7346{\pm}0.4199$이었다. W군에서는 Interval I와 I+II에서의 골 소실 양이 통계학적으로 유의할 만한 차이를 보였으며, Interval I+II에서의 W 군과 S 군에서의 골 소실 양도 통계학적으로 유의할 만한 차이를 나타내었다. Interval I에서는 두 그룹에서 골 소실의 차이가 없었는데 이는 1 stage surgery시 healing abutment 주위로 mucoperiosteal flap 접합의 어려움 때문으로 생각된다. 한편 Interval II에서는 abutment manipulation 등의 과정이 추가적인 골 소실을 야기한 것으로 생각된다. Interval I+II에서 W 군과 S 군 사이의 골 소실 양 차이는 미세 간극의 수평적 위치 변화의 양과 유사한 결과를 나타내었는데 이로 미루어 미세 간극의 수평적 이동은 임플란트 주위의 골 소실 양에 영향을 미칠 수 있다고 생각된다.

The risk factors for implant survival and marginal bone loss: a retrospective long-term study (임플란트 장기간 유지와 변연골 소실에 영향을 주는 요인들에 대한 후향적 연구)

  • Lee, Eun-Woo;Jung, Ha-Na;Jo, Yujin;Kim, Ok-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.2
    • /
    • pp.97-109
    • /
    • 2022
  • Purpose: This study aims to investigate the risk indicators contributing to implant failure, and analyze the relationship between risk indicators and marginal bone loss (MBL) through long-term follow-up over 3 years. Materials and Methods: From 2003 to 2017, patients' medical charts with a history of dental implant surgery at Chonnam National University Dental Hospital were reviewed retrospectively. The patient's demographic variables, and clinical variables were recorded. Periapical radiographs were used to evaluated the changes in MBL around implants. And we analyzed implant survival rates. Multiple regression analysis with backward elimination was conducted to correlate the patient's clinical variables and implant failure and Pearson correlation analysis was performed to the correlated between implant long-term survival rates and MBL and initial stability. Results: In multiple regression analysis, there was a statistically significant negative correlation between abutment connection type (β = -.189, P < .05), with or without SPT (β = -.163, P < .05), diabetes (β = -.164, P < .05), osteoporosis (β = -.211, P < .05) and MBL. Anticoagulant medication influenced the long-term success rate of implants. PTV values at the second implant surgery showed a statistically significant negative correlation with long-term implant survival (P < .05). Conclusion: For the long-term success of the implant, the appropriate abutment connection type must be selected and the periodic SPT is recommended. Systemic diseases such as diabetes and osteoporosis and anticoagulant medication should be considered. Furthermore, since high PTV at the second implant surgery correlated with the long-term survival rates of the implant, initial stability should be carefully considered before undergoing the prosthetic procedure.

Clinical application of mandibular removable partial denture using implant-supported surveyed crown: A case report (임플란트 지지 서베이드 금관을 이용한 하악의 가철성 국소의치 수복 증례)

  • Park, Jae-Ho;Min, Byung-Kwee;Yang, Hong-So;Park, Chan;Park, Sang-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.154-160
    • /
    • 2018
  • When making conventional removable partial denture for the remaining teeth where the remaining teeth are only on one side, rotation of the denture occurs -in function- on the axis of the connected remaining teeth. If the edentulous portion is long, it becomes harder to obtain retention and stability for the abutment as the importance of the mucous membrane support is elevated. Such movements of denture decrease denture retention and stability, put excessive stress on the abutment, and give bad influence on periodontal health. Therefore, additional implant placement can be of a good choice in gaining additional retention and stability for partial denture. Thus hereby we report this clinical case as successful results were obtained by placing implants symmetrical to the remaining teeth and putting implant-supported surveyed crowns on the implants, allowing the partial denture to be designed to accept varying components and to have suitable path of insertion.

Implant placement after guided bone regeneration (GBR) in severe defected mandibular alveolar ridge: case report (심하게 결손된 하악 치조골에서 골유도재생술(GBR) 후 임플란트의 식립: 증례보고)

  • Chee, Young-Deok;Yu, Tae-Hoon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.2
    • /
    • pp.184-191
    • /
    • 2014
  • In the mandibular posterior molar area, ridge deficiency is an unfortunate obstacle in the field of implant dentistry. Many techniques are available to rebuild the deficient ridge. Selection and necessity of these techniques are associated with significant morbidity and often require a second surgical site. With the advent of guided bone regeneration (GBR), one may now graft the deficient ridge with decreased morbidity and without a second surgical site. In this case, guided bone regeneration procedures were performed with a combination of allograft, xenograft, and alloplast, excepting autogerous bone at severe defected mandibular alveolar ridge and then placed to the implant successfully. We report that implant placement were good in two cases.