• Title/Summary/Keyword: 일산시

Search Result 241, Processing Time 0.024 seconds

Clinical analysis of acute drug intoxication and foreign body ingestion in Wonju: comparison between the 1990s and the 2000s (1990년대와 2000년대의 원주시 소아에서 발생한 급성약물중독과 이물질섭취 환아의 비교분석)

  • Eum, Joo Pil;Suh, Jin Suk;Kim, Hwang Min
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.2
    • /
    • pp.138-142
    • /
    • 2007
  • Purpose : The purpose of this study is to find out the changing pattern of drug or foreign body ingestion between 1990s and 2000s in Wonju Christian Hospital, which is located in one of the most rapidly urbanizing cities in Korea. Methods : We retrospectively reviewed the medical records of patients with acute drug intoxication and foreign body ingestion from January 1991 to December 1994 and from January 2001 to December 2004. We performed clinical analysis and compared the results of the 1990s and 2000s. Results : There were 43 cases of acute drug intoxication in the 1990s, and 35 cases in the 2000s. Foreign body ingestion was 47 cases in the 1990s and 22 cases in the 2000s. The ingested foreign bodies were chiefly coins (46.8 percent), Weiqi chips (14.9 percent), plastic toys (6.4 percent) and others (31.9 percent) in the 1990s. In the 2000s, others (58.2 percent) were the most commonly ingested foreign body with mercury batteries (23.8 percent), nails (9 percent), pins (9 percent) following. The most common cause of drug intoxication was medical drugs (37.2 percent) others (23.2 percent), agricultural agents (13.9 percent), carbon monoxide (11.6 percent), rodenticide (9.3 percent), insecticide (9.3 percent) in the 1990s. In the 2000s the most common causes were others (34.3 percent), medical drug (31.4 percent), agriculture agents (20 percent), detergent (11.4 percent), insecticide (2.9 percent) and carbon monoxide (2.9 percent). The highest incidence age group was the 1-3 year old group, both in acute drug intoxication and foreign body ingestion. There were no changes in the incidence age group between the 1990s and the 2000s. Conclusion : There were some significant changes in the cause of acute drug intoxication and foreign body ingestion between the 1990s and 2000s. New education programs for preventing acute drug intoxication and foreign body ingestion are important and necessary.

Carbon Monoxide Dispersion in an Urban Area Simulated by a CFD Model Coupled to the WRF-Chem Model (WRF-Chem 모델과 결합된 CFD 모델을 활용한 도시 지역의 일산화탄소 확산 연구)

  • Kwon, A-Rum;Park, Soo-Jin;Kang, Geon;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.679-692
    • /
    • 2020
  • We coupled a CFD model to the WRF-Chem model (WRF-CFD model) and investigated the characteristics of flows and carbon monoxide (CO) distributions in a building-congested district. We validated the simulated results against the measured wind speeds, wind directions, and CO concentrations. The WRF-Chem model simulated the winds from southwesterly to southeasterly, overestimating the measured wind speeds. The statistical validation showed that the WRF-CFD model simulated the measured wind speeds more realistically than the WRF-Chem model. The WRF-Chem model significantly underestimated the measured CO concentrations, and the WRF-CFD model improved the CO concentration prediction. Based on the statistical validation results, the WRF-CFD model improved the performance in predicting the CO concentrations by taking complicatedly distributed buildings and mobiles sources of CO into account. At 04 KST on May 22, there was a downdraft around the AQMS, and airflow with a relatively low CO concentration was advected from the upper layer. Resultantly, the CO concentration was lower at the AQMS than the surrounding area. At 15 KST on May 22, there was an updraft around the AQMS. This resulted in a slightly higher CO concentration than the surroundings. The WRF-CFD model transported CO emitted from the mobile sources to the AQMS measurement altitude, well reproducing the measured CO concentration. At 18 KST on May 22, the WRF-CFD model simulated high CO concentrations because of high CO emission, broad updraft area, and an increase in turbulent diffusion cause by wind-shear increase near the ground.

Analysis of Emission Characteristics and Emission Factors of Carbon Monoxide and Nitrogen Oxide Emitted from Wood Pellet Combustion in Industrial Wood Pellet Boilers Supplied According to the Subsidy Program of Korea Forest Service (산림청 지원사업에 따라 보급된 산업용 목재펠릿보일러에서 목재펠릿 연소 시 배출되는 일산화탄소와 질소산화물의 배출 특성 및 배출계수 분석)

  • Kang, Sea Byul;Choi, Kyu Sung;Lee, Hyun Hee;Han, Gyu-Seong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.597-609
    • /
    • 2018
  • Korea Forest Service has supplied 76 industrial wood pellet boilers from 2011 to 2015 through subsidy programs. Since carbon monoxide (CO) and nitrogen oxides ($NO_x$) generated during boiler combustion are substances that lead to death in the case of acute poisoning, it is very important to reduce emissions. Therefore, the CO and $NO_x$ emission values of 63 boilers excluding the hot air blower and some boilers initially supplied were analyzed. The emission factor was also calculated from the measured exhaust gas concentration (based on exhaust gas $O_2$ concentration of 12%). The average value of CO emitted from industrial wood pellet boilers was 49 ppm and it was confirmed that the CO concentration was decreasing as the years passed. The emission factor of CO was 0.73 g/kg. The average value of $NO_x$ emitted from industrial wood pellet boilers was 67 ppm and the emission factor of $NO_x$ was 1.63 g/kg. Unlike CO, there was no tendency to decrease according to the installation year. Both CO and $NO_x$ measurements met the limits of the Ministry of Environment. These $NO_x$ emission factors were compared with the $NO_x$ emission factors produced by certified low $NO_x$ burners. The $NO_x$ emission factor of industrial wood pellet boilers was about 1.9 times that of certified low $NO_x$ LNG combustors and about 0.92 times that of coal combustion.

Characteristics of Carbon Dioxide Reduction in the Gliding Arc Plasma Discharge (글라이딩 아크 플라즈마 방전에 의한 이산화탄소 저감 특성)

  • Lim, Mun Sup;Kim, Seung Ho;Chun, Young Nam
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.205-209
    • /
    • 2015
  • CCU (Carbon Capture & Utilization) has a potential technology for the reduction and usage of carbon dioxide which is greenhouse gas emitting from a fossil fuel buring. To decompose the carbon dioxide, a three phase gliding arc plasma-catalytic reactor was designed and manufactured. Experiments of carbon dioxide reduction was performed by varying the gas flow rate with feeding the $CO_2$ only as well as the input power, the catalyst type and steam supply with respect to the injection of the mixture of $CO_2$ and $CH_4$. The $CO_2$ decomposition rate was 7.9% and the energy efficiency was $0.0013L/min{\cdot}W$ at a $CO_2$ flow rate of 12 L/min only. Carbon monoxide and oxygen was generated in accordance with the destruction of carbon dioxide. When the injection ratio of $CH_4/CO_2$ reached 1.29, the $CO_2$ destruction and $CH_4$ conversion rates were 37.8% and 56.6% respectively at a power supply of 0.76 kW. During the installation of $NiO/Al_2O_3$ catalyst bed, the $CO_2$ destruction and $CH_4$ conversion rates were 11.5% and 9.9% respectively. The steam supply parameter do not have any significant effects on the carbon dioxide decomposition.

자동차 배출가스 규제 및 대책

  • 조병환
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.8-15
    • /
    • 1983
  • 1960년초 이래 우리나라는 고도의 경제성장을 이룩하게 되었으며 이러한 경제성장에 따른 산업화 사회의 특징인 공업화 도시화 인구집중 현상은 우리나라에도 심각한 환경오염 문제를 야기시켜 왔다. 또한 같은 기간동안 자동차의 보유대수 역시 급격한 증가를 보여왔던바, 1962년 30,000 대에서 1982년도 자동차 등록대수는 약 640,000대로 증가하게 되었으며 대부분의 자동차가 대 도시에 집중되어 있다. 특히 전체 차량의 40%가 집중되어 있는 서울시의 경우에는 자동차 배 출가스로 인한 대기오염문제가 도시민의 건강과 재산에 많은 피해를 일으키게 되었다. 우리나 라는 선진 외국의 대도시에 비해 자동차의 1일 주행거리가 3배 내지 5배를 더 주행하고 있고 자동차 배출가스 기준의 완화, 노후차량의 증가, 도로율의 불황 및 도로조건의 불비 등은 도시 중심천의 자동차 집중현상과 함께 자동차 배출가스로 인한 대기오염 문제가 보다 더 심각하게 우려되었고, 따라서 자동차 배출가스규제 강화의 필연성이 계속해서 주장되어 왔다. 자동차로 인한 공해문제는 1940년도 후반 미국 남부 California 지방에서 광화학스모그의 발생과 함께 거 론되기 시작하였으나 본격적으로 문제가 제기된 것은 급격한 자동차 증가로 인한 도시민의 건 강피해가 발생하기 시작한 것은 1960년대이다. 처음으로 규제되기 시작한 것은 1965년 미국에서 "자동차 오염방지법"의 제정부터이며 1968년부터 자동차 배출가스에 대한 규제가 시작되었다. 한편 일본은 1973년, 유럽에서는 1975년부터 일산화탄소, 탄화수소, 질소산화물 및 매연에 대한 규제를 시작하게 되었다. 우리나라에서는 "도로운송차량법"에서 도로교통의 안전과 질서유지라는 측면에서 일부 규제하여 오다가 1977년말 "환경보전법"이 제정 공포되면서 1980년 1월 환경정의 발족과 함께 실제로 자동차 배출가스를 규제하게 되었다.발족과 함께 실제로 자동차 배출가스를 규제하게 되었다.을 SUP7H종으로 더욱 향상된 것이 실용 화되고 있다. 아래에서 이에 대한 기계적 특성을 중심으로 검토키로 한다.9%내인 0.07cm 정도였으나 1973년과 1974년의 방축년에는 조차 3개 처리구(3.4-5.18cm)에 필적되는 연평균 4.16cm로 나타났다. 5. 전체 시험구로부터으 연평균 토양유실량은 Sharpsburg 점질양토에 대한 S.C.S 한계허용치 10ton/ha/year 이내로 나타났다. 비처리구에서의 토양유실량은 평균 2.56ton/ha/year로 높게 나타난 반면 3개의 서로 다른 추리구인 비수구, 초생수로구 및 Bromegrass구에서는 각각 0.152, 0.192 및 0.290ton/ha/year로 낮은 결과를 가져왔다. 6. 평균 침전량에 대한 L.S.D. 검정 걸과 전시험구중 비처리구가 고도의 유의차를 나타낸 반면 비수구, 초생수로구 및 Bromegrass 목초구 간에는 아무런 유의차가 인정되지 않았다. 7. 농지보전 처리구인 배수구와 초생수로구는 비처리구에 비해 낮은 침두 유출량과 낮은 토양유실량을 나타내었다.구보다 14% 절감되는 것으로 나타났다.작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수록 현저했다. 주상에서 관측된 이러한 특성은 서브스톰 확장기 활동이 자기폭풍의 발달과 밀접한 관계가 있음을 시사한다.se that were all low in two aspects, named "the Nonsignificant group". And the issues were high risk perception in

  • PDF

A Study on the Emission Factor of NOx and CO by Burning of Synthetic Biogas (합성 Bio-Gas 연소시 발생되는 질소산화물과 일산화탄소 배출에 관한 연구)

  • An, Jae-Ho;Kim, Tae-Wan;Lee, Sang-Eun
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • In view of energy supply, biogas can be seen as alternative fuel by substituting considerable amount of fossil fuel and may be utilized for heat and power production or for transport fuel production ($CH_4-enriched$ biogas). The aim of this research is to analyse the emission of $NO_x$ and CO from biogas fired combustion engine for electric power production. The result indicate a significant effect of biogas composition ($CH_4-CO_2$ ratio) and biogas flow rate on the air pollutants emission. The emission factors from this study were compared with those of U.S. EPA. Low $CH_4-CO_2$ ratio condition typically shows the lower $NO_x$ and CO emission than higher $CH_4-CO_2$ ratio condition. At normal $CH_4-CO_2$ ratio (7:3) emission factors of $NO_x$ and CO were 1.29 and 30.43 g/MMBtu, respectively. At low $CH_4-CO_2$, ratio (6:4) emission factors of $NO_x$ and CO were 0.646 and 60.86 g/MMBtu, respectively, It should be emphasized that the actual emission may vary considerably from these results due to operating conditions including torque load and engine speed.

Antimicrobial and Antioxidant Activities and Inhibition of Nitric Oxide Synthesis of Oak Wood Vinegar (참나무 목초액의 항균 및 항산화 활성과 일산화질소 합성 저해연구)

  • Jung, Il-Sun;Kim, Yu-Jung;Gal, Sang-Wan;Choi, Young-Ju
    • Journal of Life Science
    • /
    • v.17 no.1 s.81
    • /
    • pp.105-109
    • /
    • 2007
  • This study was carried out to investigate the biological effects oak wood vinegar. Antimicrobial activity was tested in five microbial species at the concentration of 5 to $50{\mu}l$ of oak wood vinegar by paper disc method. Growth of P. oleovoranse, P. vulgaris, E. coli, S. aureus and Prevotella intermedia was inhibited at a dose of as low as $50{\mu}l$ of oak wood vinegar. Antioxidant activities were measured by using DPPH radical scavenging and SOD-like activity. DPPH radical scavenging and SOD-like activities were 90% and 65% at the concentration of $25{\mu}l\;and\;50{\mu}l$ of oak wood vinegar, respectively. Stimulation of the macrophages RAW264.7 cells with lipopolysaccharide (LPS) resulted in increased production of nitric oxide (NO) in the medium. However, the oak wood vinegar showed marked inhibition of NO synthesis in a dose-dependent manner. This result suggest that oak wood vinegar plays significant role for activation of immune system in the pathogenesis of inflammatory diseases.

Development of Novel Sulforaphane Contained-composition to Increase Antioxidant and Whitening Effects (항산화와 미백효과를 증진시킨 새로운 Sulforaphane 함유 혼합 조성의 개발)

  • Lee, Ji Hye;Choi, Kang Hyun;Park, Young Kum;Kim, Eung-Gook;Shin, Eun-Young
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.4
    • /
    • pp.437-445
    • /
    • 2018
  • In this study, we analyzed two components, sulforaphane and PF-3758309 to prove that the mixed composition of them has more effective antioxidant and whitening functions compared to each component. We analyzed the cellular toxicity of each component and also the mixed composition to find the safe concentration level for cell viability. From the single component treatment, we discovered that sulforaphane was safe up to $10{\mu}M$, and PF-3758309 up to 100 nM. Combination treatment of $10{\mu}M$ sulforaphane and 1 nM PF-3758309 did not affect the cell viability. The LPS-stimulated NO generation was significantly reduced by the mixed composition of sulforaphane and PF-3758309. Melanogenesis by ${\alpha}$-melanocyte stimulating hormone (${\alpha}$-MSH) was also inhibited by the mixed composition. In order to confirm the possibility as the cosmetic material, we carried out clinical studies for the mixed composition samples. Skin safety evaluation using patch test was judged to be unstimulated, skin whitening effect was increased, and melanin deposition was suppressed by treatment of mixed composition samples. These results provide us with the opportunity for applying it into the development of new functional cosmetics.

Effect of Hydrogen Peroxide Enema on Recovery of Carbon Monoxide Poisoning (과산화수소 관장이 급성 일산화탄소중독의 회복에 미치는 영향)

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.20 no.1
    • /
    • pp.53-63
    • /
    • 1986
  • Carbon monoxide(CO) poisoning has been one of the major environmental problems because of the tissue hypoxia, especially brain tissue hypoxia, due to the great affinity of CO with hemoglobin. Inhalation of the pure oxygen$(0_2)$ under the high atmospheric pressure has been considered as the best treatment of CO poisoning by the supply of $0_2$ to hypoxic tissues with dissolved from in plasma and also by the rapid elimination of CO from the carboxyhemoglobin(HbCO). Hydrogen peroxide $(H_2O_2)$ was rapidly decomposed to water and $0_2$ under the presence of catalase in the blood, but the intravenous administration of $H_2O_2$ is hazardous because of the formation of methemoglobin and air embolism. However, it was reported that the enema of $H_2O_2$ solution below 0.75% could be continuously supplied $0_2$ to hypoxic tissues without the hazards mentioned above. This study was performed to evaluate the effect of $H_2O_2$ enema on the elimination of CO from the HbCO in the recovery of the acute CO poisoning. Rabbits weighting about 2.0 kg were exposed to If CO gas mixture with room air for 30 minutes. After the acute CO poisoning, 30 rabbits were divided into three groups relating to the recovery period. The first group T·as exposed to the room air and the second group w·as inhalated with 100% $0_2$ under 1 atmospheric pressure. The third group was administered 10 ml of 0.5H $H_2O_2$ solution per kg weight by enema immediately after CO poisoning and exposed to the room air during the recovery period. The arterial blood was sampled before and after CO poisoning ana in 15, 30, 60 and 90 minutes of the recovery period. The blood pH, $Pco_2\;and\;Po_2$ were measured anaerobically with a Blood Gas Analyzer and the saturation percentage of HbCO was measured by the Spectrophotometric method. The effect of $H_2O_2$ enema on the recovery from the acute CO poisoning was observed and compared with the room air group and the 100% $0_2$ inhalation group. The results obtained from the experiment are as follows: The pH of arterial blood was significantly decreased after CO poisoning and until the first 15 minutes of the recovery period in all groups. Thereafter, it was slowly increased to the level of the before CO poisoning, but the recovery of pH of the $H_2O_2$ enema group was more delayed than that of the other groups during the recovery period. $Paco_2$ was significantly decreased after CO poisoning in all groups. Boring the recovery Period, $Paco_2$ of the room air group was completely recovered to the level of the before CO Poisoning, but that of the 100% $O_2$ inhalation group and the $H_2O_2$ enema group was not recovered until the 90 minutes of the recovery period. $Paco_2$ was slightly decreased after CO poisoning. During the recovery Period, it was markedly increased in the first 15 minutes and maintained the level above that before CO Poisoning in all groups. Furthermore $Paco_2$ of the $H_2O_2$ enema group was 102 to 107 mmHg and it was about 10 mmHg higher than that of the room air group during the recovery period. The saturation percentage of HbCO was increased up to the range of 54 to 72 percents after CO poisoning and in general it was generally diminished during the recovery period. However in the $H_2O_2$ enema group the diminution of the saturation percentage of HbCO was generally faster than that of the 100% $O_2$ inhalation group and the room air group, and its diminution in the 100% $O_2$ inhalation group was also slightly faster than that of the room air group at the relatively later time of the recovery period. In conclusion, the enema of 0.5% $H_2O_2$ solution is seems to facilitate the elimination of CO from the HbCO in the blood and increase $Paco_2$ simultaneously during the recovery period of the acute CO poisoning.

  • PDF

Analyses of factors that affect PM10 level of Seoul focusing on meteorological factors and long range transferred carbon monooxide (서울시 미세먼지 농도에 영향을 미치는 요인 분석 : 기상 요인 및 장거리 이동 물질 중 일산화탄소를 중심으로)

  • Park, A.K.;Heo, J.B.;Kim, H.
    • Particle and aerosol research
    • /
    • v.7 no.2
    • /
    • pp.59-68
    • /
    • 2011
  • The objective of the study was to investigate the main factors that contribute the variation of $PM_{10}$ concentration of Seoul and to quantify their effects using generalized additive model (GAM). The analysis was performed with 3 year air pollution data (2004~2006) measured at 27 urban sites and 7 roadside sites in Seoul, a background site in Gangwha and a rural site in Pocheon. The diurnal variation of urban $PM_{10}$ concentrations of Seoul showed a typical bimodal pattern with the same peak times as that of roadside, and the maximum difference of $PM_{10}$ level between urban and roadside was about $14{\mu}g/m^{3}$ at 10 in the morning. The wind direction was found to be a major factor that affects $PM_{10}$ level in all investigated areas. The overall $PM_{10}$ level was reduced when air came from east, but background $PM_{10}$ level in Gangwha was rather higher than the urban $PM_{10}$ level in Seoul, indicating that the $PM_{10}$ level in Gangwha is considerably influenced by that in Seoul metropolitan area. When hourly variations of $PM_{10}$ were analyzed using GAM, wind direction and speed explained about 34% of the variance in the model where the variables were added as a 2-dimensional smoothing function. In addition, other variables, such as diurnal variation, difference of concentrations between roadside and urban area, precipitation, month, and the regression slope of a plot of carbon monooxide versus $PM_{10}$, were found to be major explanatory variables, explaining about 64% of total variance of hourly variations of $PM_{10}$ in Seoul.