• Title/Summary/Keyword: 인체 측정치

Search Result 137, Processing Time 0.025 seconds

A Study on MZ Generation(2030s) Male Body Shape Comparison and Body Shape Change - Focused on the 7th and 8th Size Korea's Anthropometric Data - (MZ세대(2030대) 남성의 체형비교 및 체형 변화 연구 - 제 7차, 제 8차 사이즈코리아 직접 측정치를 기준으로 -)

  • Ji-Eun Kim;Eun-Kyong Kim
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.25 no.1
    • /
    • pp.33-47
    • /
    • 2023
  • In this study, the difference in human body dimensions between the age groups of Generation M (27 to 39 years old) and Generation Z (20 to 26 years old) was analyzed. This study also analyzed if there was a change in the body shape of the MZ generation, who have different sensibilities from the "young people" of the past. In addition, major changes in human body dimensions were carefully analyzed and presented as basic data for clothing design. Therefore, a t-test was performed to verify the significant differences in the measurements of each age group. To examine the change in human body measurements according to the measurement year, the 7th and 8th size Korea data statistics were analyzed. The main required dimensions of clothing design were analyzed graphically for visual changes according to measurement year and age group. As a result of the analysis, Generation Z was found to have a difference in body shape from Generation M, and is generally smaller and slimmer with broader shoulders. In addition, the body shape change between the 7th and 8th measurement periods was significantly higher than the 8th measurement overall. Height has increased and back length has become shorter, resulting in a larger ratio of lower body length. In addition, the proportion of obesity abnormalities has increased. Therefore, since the dimensional system set from the past data can cause problems for the fitting of clothing for the MZ generation, it is necessary to design the clothing and reset the dimensional system making it suitable for the changed the body shape of the MZ generation.

Analysis of Lower Somatotype on Adult Women and Appearance Analysis of Flare Skirts by using the Image Processing (성인 여성의 하반신 체형분석과 염상처리를 이용한 플레어 스커트의 외관분석)

  • Lee, Soo-Jung;Hong, Jeong-Min
    • Fashion & Textile Research Journal
    • /
    • v.1 no.3
    • /
    • pp.252-258
    • /
    • 1999
  • The aims of this study is to classify the lower somatotype of adult women and appearance analysis on the shape of flare skirts by using the image processing. Also We have made skirts in order to analyze the various types of appearance of flare skirts by using the image processing. The subjects for our wear test lower somatotype, who were controlled in their waist, abdomen and hip shapes. The flare skirts used for wear test were 112 types(combinated 14 fabric type and 8 lower somatotype). The effect of lower somatotype on the shape of flare skirts was determined by the horizontally hem line section shape and the silhouette of flare skirts with image processing. The data were analyzed by using analysis of variance and Turkey, Duncan multiple range test. The results obtained are summarized as follows: It is shown that the fabric weight elongation differs in fabrics properties, in direction of textures. The shape horizontal section of flare skirt hem line has differed with the number of nodes, wave-height of nodes and breadth of silhouette by fabrics properties and lower somatotype. It is noticed that the breadth of flare skirts by the silhouette has high correlation with the drape ability of fabrics and lower somatotype. Results for our flare skirts show changes in amplitude and mean with fabrics, somatotype. Therefore we can say that gray-level histograms are correlated with changes in appearance, differences in drape spacing and related fabric properties and their somatotype.

  • PDF

Evaluation of VOCs Concentrations for Ventilation System in Subway (지하철 역사내 효과적인 환기체계 정립을 위한 휘발성유기화합물 농도 평가)

  • 조장제;장정욱;최우건;김태오;박덕신;정우성
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.431-432
    • /
    • 2003
  • 급속한 도시화, 인구 과밀화로 인한 교통문제와 생활공간의 확보는 현재 대도시가 직면한 사회적인 문제이다. 이와 같은 대도시의 교통문제를 해결하기 위해 건설된 지하철은 인구의 도시집중으로 인해 발생하는 교통량의 증가를 효과적으로 관리할 수 있는 유일한 운송 수단이다. 이러한 지하철의 이용공간은 밀폐성으로 인해 환기가 용이치 않고, 그로 인한 유해물질의 축적으로 인체에 대한 위해성이 대두되고 있다. 이에 본 연구에서는 지하공간 내 오염물질 중 가스상 오염물질 즉, 휘발성유기화합물질(VOCs)을 측정, 분석함으로써 지하역사내의 쾌적한 환경을 확보하기 위한 효과적인 방안을 정립하는데 일조 하고자 한다. (중략)

  • PDF

유류 오염 부지에 대한 위해성 평가 -RBCA를 중심으로-

  • 류상민;함세영;정재열;신현무;오방일;김민철
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.370-373
    • /
    • 2002
  • 위해성 평가(Risk assessment)는 지하수나 토양의 오염으로 인해 자연 환경과 사람에게 미칠수 있는 위해(risk)를 정량적으로 평가하는 방법이다. 이 평가를 바탕으로 대상지역의 오염도 저감 여부 및 목표를 설정할 수 있다. 본 연구에서는 유류로 오염된 부지를 대상으로 측정된 TPH(Total Petroleum Hydrocarbon)값에 근거하여 인체에 미칠 수 있는 위해((Risk)에 대한 정량적인 평가와 동시에 오염된 토양 및 지하수의 정화기준을 산정 하고자하였다. 그 결과 유류로 오염된 00지구에 대한 정화기술적용시의 최소성분감소비(CRF)를 산출하여 정화의 정도치와 정화목표농도를 산출하였다.

  • PDF

Experimental Research for Traction force Sensor Development on Drawing Exercise Medical Instrument (재활 및 교정을 위한 견인운동치료기의 견인측정센서 개발에 관한 실험적 연구)

  • Lee, Sang-sik;Park, Won-yeop;Lee, Choong-ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.2
    • /
    • pp.3-8
    • /
    • 2009
  • The traction system has been mainly used for rehabilitation and correction of patients with spine or gait diseases in orthopedics or at home. Some problems could occur in human body when patients forced their training using the traction system. So it needs to measure a traction force and control the training time. However, most of products on market have no sensor measuring traction force. Thus we designed and made a sensor detecting traction force using strain gauge, amplifier for transition to output signal and experiment devices for performance test. We carried out experiment of a sensor detecting a traction force and measured electric responses of it with respect to traction loads. Maximum error was within about 1% for experiments in static condition and the average error was about 0.7% for experiments in dynamic condition. We concluded that it is possible to use the developed sensor for measurement of traction force since the maximum output variation of a sensor detecting a traction force was about 0.3% in $0^{\circ}C-60^{\circ}C$ temperature condition.

  • PDF

Development of 2.5D Electron Dose Calculation Algorithm (2.5D 전자선 선량계산 알고리즘 개발)

  • 조병철;고영은;오도훈;배훈식
    • Progress in Medical Physics
    • /
    • v.10 no.3
    • /
    • pp.133-140
    • /
    • 1999
  • In this paper, as a preliminary study for developing a full 3D electron dose calculation algorithm, We developed 2.5D electron dose calculation algorithm by extending 2D pencil-beam model to consider three dimensional geometry such as air-gap and obliquity appropriately. The dose calculation algorithm was implemented using the IDL5.2(Research Systems Inc., USA), For calculation of the Hogstrom's pencil-beam algorithm, the measured data of the central-axis depth-dose for 12 MeV(Siemens M6740) and the linear stopping power and the linear scattering power of water and air from ICRU report 35 was used. To evaluate the accuracy of the implemented program, we compared the calculated dose distribution with the film measurements in the three situations; the normal incident beam, the 45$^{\circ}$ oblique incident beam, and the beam incident on the pit-shaped phantom. As results, about 120 seconds had been required on the PC (Pentium III 450MHz) to calculate dose distribution of a single beam. It needs some optimizing methods to speed up the dose calculation. For the accuracy of dose calculation, in the case of the normal incident beam of the regular and irregular shaped field, at the rapid dose gradient region of penumbra, the errors were within $\pm$3 mm and the dose profiles were agreed within 5%. However, the discrepancy between the calculation and the measurement were about 10% for the oblique incident beam and the beam incident on the pit-shaped phantom. In conclusions, we expended 2D pencil-beam algorithm to take into account the three dimensional geometry of the patient. And also, as well as the dose calculation of irregular field, the irregular shaped body contour and the air-gap could be considered appropriately in the implemented program. In the near future, the more accurate algorithm will be implemented considering inhomogeneity correction using CT, and at that time, the program can be used as a tool for educational and research purpose. This study was supported by a grant (#HMP-98-G-1-016) of the HAN(Highly Advanced National) Project, Ministry of Health & Welfare, R.O.K.

  • PDF

Classification of Middle Aged Women's Breast Shapes Using 3D Body Measurement Data (3차원 인체 측정치들을 이용한 중년 여성의 유방 형태에 따른 유형)

  • Lee, Hyun-Young;Hong, Kyung-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.3
    • /
    • pp.385-392
    • /
    • 2010
  • The breast types of middle-aged women of 80A (formerly 80B) size were classified through a 3D scanned nude body. Thirty seven measurements including the radius of curvature, surface area, volume, surface length, and breast displacements were used as input variables. We extracted five main factors through the factor analysis of the measurements and classified 36 subjects into 3 clusters through the cluster analysis. As a result of the factor analysis, the size of the breast, breast sag, the curvature of the inner and the outer breast curve, the width of the breast, and the nipple direction were found as the main factors. For the results of the classification of breast types, Cluster 1 was characterized by narrow breast width and unsymmetrical under the breast curve, whereas Cluster 2 was a wide and sagged shape. Cluster 3 was classified into big breast volume and symmetrical under-breast curve. The results are useful to the product development of high quality brassieres which reflect the 3D characteristics of breast types of middle-aged women.

Study of the BIA component analysis for medical device companies (의료기기 기업을 위한 BIA 성분분석에 대한 연구)

  • Park, Eun Ju;Park, Roh Gook
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.9 no.6
    • /
    • pp.145-152
    • /
    • 2014
  • This Study was done to estimate the availability of biological resistance analysis method in medical equipment companies in Korea, and if it is usefull in predicting risk of obesity and cardiovascular disease and managing of it, by means of comparing it with blood tests. Especially, we analyzed the correlation between circumference length and fat thickness of each site of body area, which are ones of among measurement values of the BIA. This study has the purpose to propose the use of BIA as basement of diagnosis for efficient management and assessment in the medical device industry in our country.

  • PDF

Measurement of Local Motional Characteristics of Cilia in Respiratory Epithelium Using Image Analysis (영상 분석 방법을 이용한 점막 세포 섬모의 국소적 운동 특성(CBF)의 정량화에 관한 연구)

  • 이원진;박광석
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.113-118
    • /
    • 1998
  • By their rapid and periodic actions, the cilia of the human respiratory tract play an important role in clearing inhaled noxious particles. Based on the automated image-processing technique, we studied the method analyzing ciliary beat frequency (CBF) objectively and quantitatively. Microscopic ciliary images were transformed into digitized gray ones through an image-grabber, and from these we extracted signals for CBF. By means of a FFT, maximum peak frequencies were detected as CBFs in each partitioned block for the entire digitized field. With these CBFs, we composed distribution maps visually showing the spatial distribution of CBFs. Through distribution maps of CBF, the whole aspects of CBF changes for cells and the difference of CBF of neighboring cells can be easily measured and detected. Histogram statistics calculated from the user-defined polygonal window can show the local dominant frequency presumed to be the CBF of a cell or a crust the region includes.

  • PDF

Viscosity and Wettability of Carboxymethylcellulose(CMC) solutions and Artificial Saliva (Carboxymethylcellulose(CMC) 용액과 인공 타액의 점도와 습윤성)

  • Park, Moon-Soo;Kim, Young-Jun
    • Journal of Oral Medicine and Pain
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 2007
  • Destruction of oral soft and hard tissues and resulting problems seriously affect the life quality of xerostomic patients. Although artificial saliva is the only regimen for xerostomic patients with totally abolished salivary glands, currently available artificial salivas give restricted satisfaction to patients. The purpose of this study was to contribute to the development of ideal artificial saliva through comparing viscosity and wettability between CMC solutions and human saliva. Commercially-available CMC is dissolved in simulated salivary buffer (SSB) and distilled deionized water (DDW). Various properties of human whole saliva, human glandular saliva, and a CMC-based saliva substitutes known as Salivart and Moi-Stir were compared with those of CMC solutions. Viscosity was measured with a cone-and-plate digital viscometer at six different shear rates, while wettability on acrylic resin and Co-Cr alloy was determined by the contact angle. The obtained results were as follows: 1. The viscosity of CMC solutions was proportional to CMC concentration, with 0.5% CMC solution displaying similar viscosity to stimulated whole saliva. Where as a decrease in contact angle was found with increasing CMC concentration. 2. The viscosity of human saliva was found to be inversely proportional to shear rate, a non-Newtonian (pseudoplastic) trait of biological fluids. The mean viscosity values at various shear rates increased as follows: stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 3. Contact angles of human saliva on the tested solid phases were inversely correlated with viscosity, namely decreasing in the order stimulated parotid saliva, stimulated whole saliva, unstimulated whole saliva, stimulated submandibular-sublingual saliva. 4. Boiled CMC dissolved in SSB (CMC-SSB) had a lower viscosity than CMC-SSB (P < 0.01 at shear rate of $90s^{-1}$). 5. For human saliva, contact angles on acrylic resin were significantly lower than those on Co-Cr alloy (P < 0.01). 6. Comparing CMC solutions with human saliva, the contact angles between acrylic resin and human saliva solutions were significantly lower than those between acrylic resin and CMC solutions, including Salivart and Moi-Stir (P <0.01). The effectiveness of CMC solutions in terms of their rheological properties was objectively confirmed, indicating a vital role for CMC in the development of effective salivary substitutes.