• Title/Summary/Keyword: 인장접착강도

Search Result 305, Processing Time 0.031 seconds

Comparative Study on Test Methods for Mechanical Properties of Structural Adhesives Used in FRP Strengthening (구조보강용 FRP 함침·접착수지의 역학적 특성 분석을 위한 시험방법 비교 연구)

  • You, Young Chan;Choi, Ki Sun;Kim, Keung Hwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.12 no.2
    • /
    • pp.103-112
    • /
    • 2008
  • Pull-off test is generally used to evaluate bond strength of FRP composite with concrete at job site. However, some damages on FRP composites can not be avoided during pull-off test and moreover test range of pull-off strength is limited by maximum tensile strength of concrete. Accordingly, it is required to set-up a test method that can evaluate mechanical properties of structural adhesive indirectly prior to pull-off test. In this study, the standard test methods for structural adhesive which can simply evaluate mechanical performance of adhesive were suggested through comparative experiments from each different standard in various countries. Particularly, gluing thickness of adhesive in tensile lap-shear tests, the section dimension of compression and bending test specimens become unified, and standard test specimen size is achieved by test results.

Influence of a Flexibilizer on Physical Properties of Crumb Rubber Modified Asphalt Sealants (폐타이어 고무분말 개질 아스팔트 실란트의 물리적 특성에서 유연제의 영향)

  • Kim, Jong-Seok
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.33-40
    • /
    • 2009
  • The use of the crumb rubber as an asphalt binder modifier may contribute to road maintenance and repair. The adhesion properties of the crumb rubber modified asphalt (CRMA) sealant have attracted interest due to brittle and adhesion failure of asphalt binders at low temperatures. In this study, the influence of a flexibilizer as a modifier for CRMA at low temperatures was investigated. Their properties were measured using the penetration, the softening point, the tensile and tensile adhesion tests at low temperature. The tensile adhesion strength and the strain of CRMAs were increased with increasing ductile deformation of the CR and the asphalt binder in the flexiblizer modified CRMAs. It was found that the flexibilizer concentration was an important factor for tensile and adhesion properties of CRMAs at low temperatures.

  • PDF

THE EFFECTS OF COLLAGENASE AND ESTERASE ON THE MICROTENSILE BOND STRENGTH IN DENTIN BONDING (상아질 접착에서 collagenase와 esterase가 미세인장결합강도에 미치는 영향)

  • Jung, Young-Jung;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Lee, Sang-Hoon;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.2
    • /
    • pp.285-291
    • /
    • 2007
  • The purpose of this study was to evaluate the effect of collagenase and esterase on the microtensile bond $strength({\mu}TBS)$ in dentin bonding. After resin composites were bonded to occlusal dentin. ${\mu}TBS$ specimens were formed and stored in PBS, collagenase, or esterase solution After 4-week storage, ${\mu}TBS$ was determined and, the results were as follows : 1. ${\mu}TBS$ values of Single Bond 2 were lower than those of Clearfil SE Bond for all storage medium (p<0.05). 2. In Single Bond 2 group, collagenase solution lowered bond strength more than PBS and esterase solution (p>0.05). 3. In Clearfil SE Bond group, esterase solution lowered bond strength more than PBS(p>0.05). Collagenase solution lowered bond strength more than esterase solution(p>0.05) and PBS(p<0.05).

  • PDF

Influence of Processing Conditions on the Physical Properties of Crumb Rubber Modified Asphalts (폐타이어 고무분말 개질 아스팔트의 물리적 특성에 대한 공정조건의 영향)

  • O, Kwang-Joong;Kim, Jong-Seok
    • International Journal of Highway Engineering
    • /
    • v.10 no.3
    • /
    • pp.239-246
    • /
    • 2008
  • In this study, the influence of reaction temperatures, mixing time and flexible modifier for crumb rubber modified asphalt(CRMA) as processing conditions were investigated. The temperature susceptibility and adhesion properties of neat and modified asphalts at low temperature measured using the penetration and tensile adhesion test. It was found that processing temperatures and flexible modifier were important factors for tensile adhesion strength and toughness energy at low temperature. The CRMA in the higher processing temperature and flexible modifier exhibited improved tensile adhesion properties which indicated the flexible structure of neat and modified asphalt binder. In general, the improvements of the physical properties in the CRMAs were due to the improvements of miscibility between CR and asphalt binder. It was found that the adhesion properties of the flexible agent modified CRMA were higher than CRMA were related to the flexible agent tend to penetrate into CR particles and asphalt binder.

  • PDF

THE EFFECT OF PRIMING ETCHED DENTIN WITH SOLVENT ON THE MICROTENSILE BOND STRENGTH OF HYDROPHOBIC DENTIN ADHESIVE (산 부식된 상아질에 대한 용매를 이용한 프라이밍이 소수성 상아질 접착제의 미세인장접착강도에 미치는 영향)

  • Park, Eun-Sook;Bae, Ji-Hyun;Kim, Jong-Soon;Kim, Jae-Hoon;Lee, In-Bog;Kim, Chang-Keun;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.42-50
    • /
    • 2009
  • Deterioration of long-term dentin adhesion durability is thought to occur by hydrolytic degradation within hydrophilic domains of the adhesive and hybrid layers. This study investigated the hypothesis that priming the collagen network with an organic solvent displace water without collapse and thereby obtain good bond strength with an adhesive made of hydrophobic monomers and organic solvents. Three experimental adhesives were prepared by dissolving two hydrophobic monomers, bisphenol-A-glycidylmethacrylate (Bis-GMA) and triethyleneglycol dimethacrylate (TEGDMA), into acetone, ethanol or methanol. After an etching and rinsing procedure, the adhesives were applied onto either wet dentin surfaces (wet bonding) or dentin surfaces primed with the same solvent (solvent-primed bonding). Microtensile bond strength (MTBS) was measured at 48 hrs, 1 month and after 10,000 times of thermocycles. The bonded interfaces were evaluated using a scanning electron microscope (SEM). Regardless of bonding protocols, well-developed hybrid layers were observed at the bonded interface in most specimens. The highest mean MTBS was observed in the adhesive containing ethanol at 48 hrs. With solvent-primed bonding, increased MTBS tendencies were seen with thermo cycling in the adhesives containing ethanol or methanol. However, in the case of wet bonding, no increase in MTBS was observed with aging.

The effect of the strength and wetting characteristics of Bis-GMA/TEGDMA-based adhesives on the bond strength to dentin (2,2-Bis[4-(2-methoxy-3-methacryloyloxy propoxy) phenyl] propane을 함유한 상아질 접착레진의 물성이 접착강도에 미치는 영향)

  • Park, Eun-Sook;Kim, Chang-Keun;Bae, Ji-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.139-148
    • /
    • 2011
  • Objectives: This study investigated the effect of the strength and wetting characteristics of adhesives on the bond strength to dentin. The experimental adhesives containing various ratios of hydrophobic, low-viscosity Bis-M-GMA, with Bis-GMA and TEGDMA, were made and evaluated on the mechanical properties and bond strength to dentin. Materials and Methods: Five experimental adhesives formulated with various Bis-GMA/Bis-MGMA/TEGDMA ratios were evaluated on their viscosity, degree of conversion (DC), flexural strength (FS), and microtensile bond strength (MTBS). The bonded interfaces were evaluated with SEM and the solubility parameter was calculated to understand the wetting characteristics of the adhesives. Results: Although there were no significant differences in the DC between the experimental adhesives at 48 hr after curing (p > 0.05), the experimental adhesives that did not contain Bis-GMA exhibited a lower FS than did those containing Bis-GMA (p < 0.05). The experimental adhesives that had very little to no TEGDMA showed significantly lower MTBS than did those containing a higher content of TEGDMA (p < 0.05). The formers exhibited gaps at the interface between the adhesive layer and the hybrid layer. The solubility parameter of TEGDMA approximated those of the components of the primed dentin, rather than Bis-GMA and Bis-M-GMA. Conclusions: To achieve a good dentin bond, a strong base monomer, such as Bis-GMA, cannot be completely replaced by Bis-M-GMA for maintaining mechanical strength. For compatible copolymerization between the adhesive and the primed dentin as well as dense cross-linking of the adhesive layer, at least 30% fraction of TEGDMA is also needed.

The Evaluation of Tensile-shear Strength on the Al-Alloy Single-lap Adhesive Joints (AI합금 단순겹치기 접착이음의 인장-전단강도 평가)

  • Oh, S. K.;Yu, Y. C.;Jeong, E. S.;Yi, W.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.567-571
    • /
    • 1997
  • Recently, automobile industry has led to increasing use of aluminum alloy for weight reduction. Automobile made of aluminum alloy can be given lighter, stronger and a harder surface by anodizing than one made of steel-alloy. In this paper, we investigate the influence of lap length, adherend thickness and adhesive thickness on adhesive strength of single-lap adhesive joints by conducting tensile-shear tests. Single-lap adhesive joints of aluminum was calculated using joint factor by using adhesive length, adherend thickness of specimen.

  • PDF

Evaluation of mechanical properties of several dual-cure resin cements by curing modes (중합방법에 따른 여러 이중중합 레진 시멘트의 기계적 성질 평가)

  • Kim, Soo-Yeon;Park, Se-Hee;Kim, Jin-Woo;Cho, Kyung-Mo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the mechanical properties of several dual-cure cements by different curing modes. Materials and Methods: One resin-modified glass ionomer cement (FujiCEM 2), two conventional dual-cure resin cements (RelyX ARC, Multilink N), and two dual-cure self-adhesive resin cements (RelyX U200, G-CEM LinkAce) were used. To evaluate the influence of the curing methods, each cements divided into four conditions (n = 20); Condition 1: self-curing for 10 minutes, Condition 2: immediate after 20 seconds light-curing, Condition 3: 24 hours after self-curing, Condition 4: 24 hours after light-curing. The compressive strength and diametral tensile strength were measured with a universal testing machine. All data were statistically analyzed using t-test, one-way ANOVA and Scheffe's test. Results: The results showed the compressive strength and diametral tensile strength after 24 hours in all curing modes were higher than immediate except RelyX ARC light-cured and Multilink N light-cured. The FujiCEM 2 showed lowest values (P < 0.05). Conclusion: The outcome was cement-depend, but there is no significant difference about compressive strength and diametral tensile strength between dual-cure self-adhesive resin cements and conventional resin cements. And this result will be used as a base line data selecting resin cement for favorable long-term prognosis.

EFFECT OF THE EXPONENTIAL CURING OF COMPOSITE RESIN ON THE MICROTENSILE DENTIN BOND STRENGTH OF ADHESIVES (복합레진의 exponential 중합법이 상아질접착제의 미세인장접착강도에 미치는 영향)

  • Seong, So-Rae;Seo, Duck-kyu;Lee, In-Bog;Son, Ho-Hyun;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.35 no.2
    • /
    • pp.125-133
    • /
    • 2010
  • Objectives: Rapid polymerization of overlying composite resin causes high polymerization shrinkage stress at the adhesive layer. In order to alleviate the shrinkage stress, increasing the light intensity over the first 5 seconds was suggested as an exponential curing mode by an LED light curing unit (Elipar FreeLight2, 3M ESPE). In this study, the effectiveness of the exponential curing mode on reducing stress was evaluated with measuring microtensile bond strength of three adhesives after the overlying composite resin was polymerized with either continuous or exponential curing mode. Methods: Scotchbond Multipurpose Plus (MP, 3M ESPE), Single Bond 2 (SB, 3M ESPE), and Adper Prompt (AP, 3M ESPE) were applied onto the flat occlusal dentin of extracted human molar. The overlying hybrid composite (Denfil, Vericom, Korea) was cured under one of two exposing modes of the curing unit. At 48h from bonding, microtensile bond strength was measured at a crosshead speed of 1.0 mm/min. The fractured surfaces were observed under FE-SEM. Results: There was no statistically significant difference in the microtensile bond strengths of each adhesive between curing methods (Two-way ANOVA, p > 0.05). The microtensile bond strengths of MP and SB were significantly higher than that of AP (p < 0.05). Mixed failures were observed in most of the fractured surfaces, and differences in the failure mode were not observed among groups. Conclusion: The exponential curing method had no beneficial effect on the microtensile dentin bond strengths of three adhesives compared to continuous curing method.

Adhesion in Tension of Polymer-Modified Mortars with Blast-Furnace Slag and Fly ash (고로슬래그 및 플라이애쉬를 혼입한 폴리머 시멘트 모르타르의 인장접착강도)

  • Jo, Young-Kug
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.232-233
    • /
    • 2017
  • The purpose of this study is to evaluate the Adhesion in tension of cement mortar according to adding admixtures such as polymer dispersions, blast-furnace slag and fly ash. From the test results, the adhesion in tension is seriously affected by type of polymer compared with polymer-binder ratios and types of admixture. The maximum adhesion in tension of EVA- modified mortar is about 1.46 times, the cement mortar. It is apparent that the adhesion in tension of polymer-modified mortars according to adding two admixtures is much more improved irrespective of polymer-binder ratio.

  • PDF