• Title/Summary/Keyword: 인성 구인

Search Result 136, Processing Time 0.027 seconds

An Experimental Study on the Properties Analysis of Concrete Using Bleeding Reduction Agent (블리딩 저감제를 사용한 콘크리트의 성능분석에 관한 실험적 연구)

  • 전충근;김경민;황인성;신병철;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.669-674
    • /
    • 2002
  • This paper describes the properties analysis of concrete using bleeding reduction agent. According to the results, the fluidity and the air content of fresh concrete with increase of bleeding reduction agent show little difference in compare with plain concrete which does not use bleeding reduction agent. The efficiency of bleeding reduction agent is confirmed because in variation of W/C and slump, the increase of bleeding reduction agent dosage reduces bleeding remarkably. And the compressive strength of hardened concrete does not show any differences with increase the dosage of bleeding reduction agent. Bleeding reduction agent does not have bad effect on the quality of concrete such as fluidity, air content and the strength of hardened concrete and so on, the dosage of it can reduce bleeding effectively.

  • PDF

The Spalling Properties of High-Performance Concrete with the Kinds of Aggregates and Polypropylene Fiber Contents (골재종류 및 폴리프로필렌 섬유 혼입률 변화에 따른 고성능콘리트의 폭열 성상)

  • 이병렬;황인성;윤기원;양성환;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.76-79
    • /
    • 1999
  • The purpose of this study is to investigate the spalling properties of high-performance concrete with the kinds of aggregates and polypropylene(below PP) fiber contents. According to the experimental results, concrete contained no PP fiber take place in the form of the surface spalling and the failure of specimens after fire test regardless of the kinds of aggregates. Concrete contained more than 0.05% of PP fiber with the kinds of aggregates does not take place the spalling. Concrete using basalt has better performance in spalling resistance that concrete using granite and limestone. It is found that residual compressive strength has 50~60% of their original strength. Although specimens after exposed at high temperature are cured at water for 28days, they do not recover their original strength.

  • PDF

The Effects of Molybdenum and Nickel Addition on Impact Toughness of Austempered Ductile Cast Iron (오스템퍼 구상흑연주철의 충격인성에 미치는 Mo 및 Ni의 영향)

  • Park, Yoon-Woo;Chang, Hyun-Ku
    • Journal of Korea Foundry Society
    • /
    • v.8 no.4
    • /
    • pp.459-466
    • /
    • 1988
  • This study was carried out in the austempering temperature and time after Ni, Mo addition in purpose of modification of impact toughness of austempered ductile irons. Addition of alloy element and austempering treatment of $900^{\circ}C$ 60 minutes followed by $300^{\circ}C$, $350^{\circ}C$ and $400^{\circ}C$ for 60 minutes, in this case impact value was increased by ideal mixed structure. But impact value was decreased when holing time is 120minutes, this is attributed to segregation and carbide precipitation from high carbon austenite. Highest impact value was obtained by $350^{\circ}C$ (Mo-addition) and $400^{\circ}C$ (Ni-addition). This phenomena was caused by presence of remained austenite. At all austempering temperature,, Ni-added specimen showed higher impact values than that of Mo-added specimen. And hardness property was affected by austempering temperature and holding time rather than amounts of alloying element.

  • PDF

Influence of Chemical Admixture on Bleeding of Concrete (콘크리트의 블리딩에 미치는 혼화제의 영향)

  • 김은호;황인성;손유신;김규용;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.339-342
    • /
    • 2003
  • This study is intended to investigate the influence of chemical admixture on bleeding of concrete. According to the results, the amount of bleeding with elapse of time does not make much difference in the case of naphthalene type water reducing agent(RN), Naphthalene type high performance water reducing agent(HN) and Melamine type high performance water reducing agent(HM), but it is largest in the case of Polycarbonic acid type high performance water reducing agent(HP). Bleeding speed also is highest in the case of HP in comparison with other chemical admixture. This prove that high performance water reducing agent like HP has little effect on fluidity of concrete, but influences the amount of bleeding more greatly, instead. As properties of hardened concrete, compressive strength makes no difference in the case of RN, HN and HM, but on the other hand, it increases in the case of HP due to a decrease of air content and the large amount of bleeding.

  • PDF

Influence of Chemical Admixture on the Strength Development of Concrete at Early Age (콘크리트의 초기 강도발현에 미치는 혼화제의 영향)

  • 황인성;나운;이승훈;류현기;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.741-744
    • /
    • 2003
  • In this study, the influence of chemical admixture on early strength development of concrete is discussed. According to the results, fluidity with variation of kinds of chemical admixture is lower in the case of acceleration type than in the case of normal type. Setting time of naphthalene acceleration type is shortened by I hour, and that of melamine is nearly same, but that of polycarbonic acid is somewhat retarded in comparison with that of naphthalene normal type. Early compressive strength gains 5MPa in about 18hours regardless of the kinds of chemical admixture. But as time elapses, compressive strength is higher in order of polycarbonic acid, naphthalene and melamine type. The relativity between compressive strength and the rebound value of P-type schmidt hammer is also favorable at early age, and compressive strength of 5MPa is estimated at the rebound value of 22.

  • PDF

Influence of Environment and Construction Factor on the Bleeding of Concrete (콘크리트의 블리딩에 미치는 환경 및 시공요인의 영향)

  • 황인성;김기정;나운;김규동;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.65-68
    • /
    • 2003
  • This study is intended to look into the influence of environment and construction factor on bleeding of concrete. According to the results, as wind is light, relative humidity is high and temperature is low, the amount of bleeding increases greatly, and evaporation speed is influenced greatly by order of wind, temperature and humidity. As the properties of bleeding by construction factor, the amount of bleeding increases with an increase of placing thickness, but the bleeding ratio, the amount of bleeding per unit volume, increases with a decrease of the placing thickness. Bleeding speed is fastest at about 90 minute after placing concrete. Also, as wind is light, relative humidity is high, temperature is low and the placing thickness is thick, bleeding speed grow faster.

  • PDF

A Study on the Performance Restoration of Deteriorated Concrete by Long Distance Delivery (장시간 운반에 따라 저하된 콘크리트의 품질회복에 관한 연구)

  • Pei Chang-Chun;Jin Hu-Lin;Hwang Yin-Seong;Lee Hyung Won;Yang Seong-Hwan;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • v.y2004m10
    • /
    • pp.7-10
    • /
    • 2004
  • This paper investigated the possibility of quality restoration of deteriorated concrete caused by long distance delivery using chemical admixtures such as superplasticizer. AE agent and retarding agent. According to test results, long distance delivery lead to reducing fluidity and air content markedly, while setting time accelerated. Quality restoration agent(QRA) was made by combining super- plasticizer. AE agent and retarding agent with the proportion of 1:0.0025:0.1. It was confirmed that deteriorated concrete achieved quality restoration with the level of target slump, air content and setting time without strength loss when using QRA with proper amount.

  • PDF

기능적 자기공명영상 및 확산텐서영상을 이용한 전음성 난청과 감각신경성 난청군의 비교 연구: 예비 결과

  • 이재준;황문정;이영주;김인성;배성진;장용민;이상흔;우성구;강덕식
    • Proceedings of the KSMRM Conference
    • /
    • 2003.10a
    • /
    • pp.94-94
    • /
    • 2003
  • 목적: 기능적 자기공명영상과 확산텐서영상기법을 이용하여 전음성 난청과 감각신경성 난청에서의 뇌활성화 양상 그리고 청신경경로상의 차이점을 비교 연구하고자 하였다. 대상 및 방법: 전음성 난청군 (n=4)과 감각신경성 난청군(n=5) 그리고 정상군(n=5)에서의 기능적 자기 공명영상과 확산텐서영상을 획득하였다. 기능적 자기공명영상의 경우 1.5T Siemens MR scanner에서 BOLD 기법을 이용하여 500 Hz 순음 청각자극에 대한 뇌활성화 영역을 검출하였고 영상촬영시 발생하는 기계적 소음을 차폐하기 위한 청각자극기를 특별히 제작하여 사용하였다. 뇌백질신경로를 영상화하는 확산텐서영상은 3.0T GE whole body MR scanner를 사용하였으며 미세한 확산운동을 검출하기 위해 초고속 영상기법인 EPI 기법을 사용하였다. 영상의 화질을 높이기 위해 공간적으로 25개의 다른 방향으로 확산경사자장을 가하였다. 청신경로의 비등방성 영상, 신경로 방향 영상등을 구현하기 위해 획득한 확산영상들에 대한 영상 후처리과정을 시행하였다.

  • PDF

Quality Variation of Concrete Containing Beverage and detergent During Placement (콘크리트 타설시 음료 및 세제류 유입에 따른 품질변화)

  • No Dong-Hyun;Kim Jong-Back;Hwang Yin-Seong;Li Bai-Shou;Yang Seong-Hwan;Han Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.11a
    • /
    • pp.85-88
    • /
    • 2005
  • This study investigates influence on concrete adding beverage or detergent, by work man's mistakes during concrete placement in field. Overall, concrete adding beverage or detergent does not affect slump and air content, compared with control concrete. However concrete adding detergent resulted in significantly higher air content, due to inter facial activation ingredient. For the properties of setting time, concrete adding lactic acid beverage indicated the longest retarding properties, next was coffee and soft drink in order. Compressive strength of concrete, which retarded setting time. exhibited slightly improved value at 7 and 28 days respectively, while that of concrete adding detergent significantly decreased, due to higher air content.

  • PDF

Properties of Fire Endurance of High Performance RC Column by Loaded Heating Test (고성능 RC 기둥의 재하가열시험에 의한 내화 특성)

  • Kim Kyung Min;Kim Ki Hoon;Hwang Yin Seong;Lee Jae Sam;Lee Seong-Yeun;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.57-60
    • /
    • 2005
  • This study discusses spalling and fire enduring performance of high performance concrete (HPC) RC column subjected to loading under heating for 3 hours. According to the test, both the plain concrete and the concrete attached with fire enduring PC panel exceed allowable temperature after 60 minutes due to the exposure of steel bar and falling off of concrete resulting from severe spalling failure. It leads to buckling of main bar and at the same time, occurrence of collapse of plain HPC column member is observed after 2 hours and 1 hour 40 minutes's exposure to fire, respectively. On the other hand, HPC applying both PP fiber of 0.1$\%$ by mass of concrete and PP fiber+lateral confinement by metal lath maintains their original cross section, which is satisfied with the 3 hours fire endurance criteria, by discharging internal vapour pressure and enhanced lateral confinement force.

  • PDF