• Title/Summary/Keyword: 인성화

Search Result 306, Processing Time 0.021 seconds

Effect of Crystallization of Matrix Phase on the Fracture Toughness of Silicon Nitride Ceramics (질화규소 요업체의 기지상 결정화가 파괴인성에 미치는 영향)

  • 김남균;김도연;강대갑
    • Journal of the Korean Ceramic Society
    • /
    • v.24 no.4
    • /
    • pp.364-368
    • /
    • 1987
  • The Si5AION7 specimens containing 20% YAG composition have been sintered and then heat treated to induce the crystallization of the matrix glassy phase. Crystallization of YAG phase during the heat treatment was detected from the X-ray diffraction patterns and the consequent changes in room temperature toughness as well as in microstructures were investigated. Almost all the glassy boundary phase were found to crystallize even after 5 minutes of heat treatment and the KC at room temperature decreased accordingly. The results show that the matrix crystallization can be induced by slow cooling from the sintering temperature.

  • PDF

Gas Metal Arc Welding of Aluminum Alloys (알루미늄 합금의 GMAW 용접)

  • 윤광희;한용섭
    • Journal of Welding and Joining
    • /
    • v.12 no.1
    • /
    • pp.16-27
    • /
    • 1994
  • 1970년대 2번에 걸친 석유 파동 이후 재료의 경량화는 자동차, 우주항공분야에서 중요한 문제로 대두되었다. 알루미늄합금은 높은 강도/밀도비, 내식성, 인성 및 저온 특성을 보유하고 있어 일반 가정용품에서 자동차, 우주항공, 선박같은 수송장비까지 여러분야에 사용되고 있으며, 그 사용량과 적용분야는 해가 갈수록 증가하고 있다. 알루미늄합금의 용접특성과 용접 시공기술에 대한 연구결과는 상당히 많이 발표되어 있으나, 실제 현장용접시에는 기공, 불완전 용입 등의 예상치 못한 용접불양이 발생한다. 알루미늄합금의 용접 방법으로는 GTAW, GMAW 등의 보호가스 용접이 주로 사용되고 있다. 본 고에서는 알루미늄합금의 GMAW용접 특성과 용접시 용접 결함에 대하여 간단히 기술하고자 한다.

  • PDF

대법원 판결 다이제스트 - 2012. 1. ~ 2. 대법원 공정거래 사건 판결 요지

  • Yun, In-Seong
    • Journal of Korea Fair Competition Federation
    • /
    • no.161
    • /
    • pp.132-141
    • /
    • 2012
  • 대법원이 2012년 1월부터 2월까지 사이에 선고 한공정거래 관련 판결 중 일부를 소개한다. 그 중 가격담합 등의 사건에서 평균매출액 개념, 조사 협조자에게 적용되는 정확한 법령에 관한 대법원 2012. 1. 27 선고 2010두24388 판결, "하도급거래 공정화에 관한 법률"상 경쟁입찰에 관한 대법원 2012. 2. 23. 선고 2011두23337 판결이 특히 중요한 의의를 가지고 있는 것으로 보인다.

  • PDF

A study on the fracture toughness degradation in cryogenic structural material using single-specimen method (단일 시험편법에 의한 극저온용 구조재료의 파괴인성 저하에 관한 연구)

  • Kwon, Il-hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.343-351
    • /
    • 1998
  • This paper was investigated degradation of the fracture toughness caused by sensitizing heat-treatment of the cryogenic structural material JN1 base metal using unloading compliance method reported as useful a method in evaluating the elastic-plastic fracture toughness at cryogenic temperature. The specimens used in this paper were 20% side-grooved 0.5T-CT specimens which were machined in the JN1 base metal. Also, to investigate cryogenic fracture toughness of the fusion line region in the JN1 GTA weldments, it was also used 20% side-grooved 0.5T-CT specimens that was machined fusion line to located in the middle of the specimen. The cryogenic fracture toughness values of the JN1 base metal were significantly decreased with increasing the time and temperature of the heat treatment. The fracture toughness value obtained from the fusion line specimen was invalid, but it was lower value than that of the JN1 base metal. Especially, this value was approximately equal with that obtained from the JN1 650.deg. C-5h heat-treated material.

Mechanical Properties of SiC-$Si_3$$N_4$Composites Containing $\beta$-$Si_3$$N_4$Seeds ($\beta$-$Si_3$$N_4$종자입자 첨가 SiC-$Si_3$$N_4$복합재료의 기계적 특성)

  • 이영일;김영욱;최헌진;이준근
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.1
    • /
    • pp.22-27
    • /
    • 2001
  • $\beta$-Si$_3$N$_4$종자입자 첨가가 소결조제로 Y-Mg-Si-Al-O-N계 oxynitride glass를 사용하여 일축가압 소결을 행한 SiC-Si$_3$N$_4$복합재료의 미세구조와 기계적 특성에 미치는 영향을 고찰하였다. 길게 자란 $\beta$-Si$_3$N$_4$입자들과 등방성의 $\beta$-SiC 입자들이 균일하게 분포된 미세구조를 얻었다. $\beta$-Si$_3$N$_4$종자입자 함량이 증가함에 따라 SiC-Si$_3$N$_4$복합재료의 강도와 파괴인성이 증가하였고, 이는 복합화에 기인하는 결함크기의 감소와 길게 자란 $\beta$-Si$_3$N$_4$입자에 의한 균열가교 및 균열회절 등에 기인하였다. SiC-70 wt% Si$_3$N$_4$복합재료의 대표적인 강도와 파괴인성은 각각 770 MPa과 6.2 MPa.m$^{1}$2/ 이었다.

  • PDF

Tribological Properties of Hot Pressed SiC/$Si_3$$N_4$/SiCw Composites (가압소결 SiC/$Si_3$$N_4$/SiCw 복합체의 마찰마모특성)

  • Baik, Yong-Hyuck;Choi, Woong;Kang, Seon-Myung;Park, Yong-Kap
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.11
    • /
    • pp.1039-1043
    • /
    • 2000
  • $\alpha$-Si$_3$N$_4$가 20vol% 혼합된 SiC/Si$_3$N$_4$혼합물에서 $\alpha$-SiC의 일부를 SiC whisker로 치환하여 첨가한 후 180$0^{\circ}C$, 25MPa의 압력으로 hot pressing하여 SiC/Si$_3$N$_4$/SiCw 복합체를 제조하였다. SiC whisker의 첨가 함량이 증가할수록 상대밀도, 꺽임강도, 마모 저항성은 감소되었으나, 파괴인성은 크게 향상되었다. $\alpha$-SiC의 일부를 SiC whisker로의 치환은 치밀화를 억제하였으나 파괴인성의 증가는 마모 저항성을 향상시키지 않았다.

  • PDF

Validation of the Personality Measurement Tools for College Students: Focusing on Nursing Students (대학생 인성 측정도구의 타당화 : 간호대학생을 대상으로)

  • Heo, Myoung Lyun;Jang, Yang-min
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.25 no.3
    • /
    • pp.321-330
    • /
    • 2019
  • Purpose: The purpose of this study was to analyze the validity and reliability of the personality measurement tool for nursing college students. Methods: Questionnaires were issued to 300 nursing students, with 275 eventually collected. The items were confirmed by validity experts. Construct validity was tested using exploratory factor analysis and confirmatory factor analysis. Reliability analysis was tested using Cronbach's ${\alpha}$. Criterion validity was tested by analyzing correlation with the college adjustment scale. Results: Eight factors were confirmed by exploratory factor analysis. Confirmatory factor analysis was used to confirm the model fit (Root-mean-square residual .03; Root-mean-square error of approximation .06; Comparative fit index .92); and convergent validity and discriminant validity were confirmed. In addition, the criterion validity was confirmed through correlation (r=.64, p<.001) with the college adjustment scale. The reliability of this tool was Cronbach's ${\alpha}$ .94. Conclusion: This tool can be used to measure personality in nursing education and can be used to develop and evaluate personality programs.

Educational Peptide Mapping of Protein-based Biopharmaceuticals by using LC-MS/MS (LC-MS/MS를 이용한 단백질 의약품 맵핑 교수법)

  • Kim, Junseok
    • Journal of Practical Engineering Education
    • /
    • v.14 no.2
    • /
    • pp.327-332
    • /
    • 2022
  • This experiment presents a precise analysis method using a mass spectrometer in the biopharmaceutical market, where utility is expanding. Among various techniques for analyzing the protein drug, somatotropin, the peptide fragments through biochemical sample preparation was analyzed by LC-MS/MS characterization. The analysis process was performed by separation analysis using nanoUPLC and MS/MS analysis using Orbitrap. In the case of somatotropin with 21 tryptic peptides, 13 of them were consistent with theoretical predictions within an average of 1 ppm error.

Evaluation of Interfacial Properties on the Electrodeposited Carbon Fiber Reinforced Polyetherimide Toughened Epoxy Composites using Micromechanical Test (Micromechanical 시험법을 이용한 전기증착된 탄소섬유 강화 Polyetherimide로 강인화된 에폭시 복합재료의 계면물성 평가)

  • 박종만;김대식;공진우;김민영;김원호
    • Composites Research
    • /
    • v.15 no.3
    • /
    • pp.39-44
    • /
    • 2002
  • Interfacial properties and microfailure modes or electrodeposition(ED) treated carbon fiber reinforced polyetherimide(PEI) toughened epoxy composites were investigated using microdroplet test. ED was performed to improve the interfacial shear strength(IFSS). As PEI content increased, IFSS increased due to enhanced toughness and plastic deformation of PEI. In the untreated cafe, IFSS Increased with adding PEI content, and IFSS of pure PEI matrix showed the highest. On the other hand, thor ED-treated case IFSS increased with PEI content with rather low improvement rate. In the untreated case, neat epoxy resin appeared brittle microfailure mode, whereas pure PEI matrix exhibited more likely ductile microfailure mode. In the ED-treated case, neat epoxy exhibited more ductile fracture compared to the untreated case. Interfacial properties of epoxy-PEI composite can be affected efficiently by both the control of matrix toughness and ED treatment.

A Proposal for Workers to Mandatorily Wear High-visibility Safety Clothing in Korea through the Analysis of the Current Status and Evaluation of Its Visibility (국내 고시인성 안전의복의 착용 현황 분석 및 시인성 평가를 통한 착용 의무화 제안)

  • Kang, Inhyeng;Choe, Byongho;Oh, Cheol;Youk, Ji Ho
    • Fashion & Textile Research Journal
    • /
    • v.24 no.4
    • /
    • pp.471-478
    • /
    • 2022
  • In roadside workplaces, more attention should be paid to the safety of workers. The roadside workers underestimate the effect of the brightness of their clothes and judge that drivers will recognize them easily, and the drivers misjudge that the roadside workers are far away and that the vehicle can be stopped in sufficient time. Therefore, customized safety education reflecting this and wearing work clothes with certified visibility functions are required. In Korea, it is not compulsory for roadside workers and vehicle guide attendants to wear work clothes with a visibility function. In this study, the distance ahead perceived by drivers was measured using manikins wearing certified and non-certified reflective safety vests. The perception distance of the non-certified reflective safety vest was 1.4 times longer than that of the certified reflective safety vest, thus confirming the importance of wearing a certified reflective safety vest. To prevent roadside workers from suffering traffic accidents, we propose the enactment of a law that makes it mandatory for them to wear high-visibility safety clothing. Specifically, Article 32 of the Enforcement Regulation of the Road Traffic Act should include high-visibility safety clothing in life protection equipment, and additionally, to prevent secondary accidents, we propose the enactment of a law requiring the installation and wearing of certified reflective safety vests in vehicles.