Abstract
This experiment presents a precise analysis method using a mass spectrometer in the biopharmaceutical market, where utility is expanding. Among various techniques for analyzing the protein drug, somatotropin, the peptide fragments through biochemical sample preparation was analyzed by LC-MS/MS characterization. The analysis process was performed by separation analysis using nanoUPLC and MS/MS analysis using Orbitrap. In the case of somatotropin with 21 tryptic peptides, 13 of them were consistent with theoretical predictions within an average of 1 ppm error.
Keywords
LC-MS/MS; Protein drug; Somatotropin; Tryptic peptide;
Citations & Related Records
연도 인용수 순위
  • Reference
1 N. L. Anderson, M. Polanski, R. Pieper, T. Gatlin, R. S. Tirumalai, T. P. Conrads, T. D. Veenstra, J. N. Adkins, J. G. Pounds, R. Fagan, and A. Lobley, "The human plasma proteome: a nonredundant list developed by combination of four separate sources," Molecular & Cellular Proteomics, vol. 3, no. 4, pp. 311-326, April 2004.   DOI
2 T. Mouchahoir and J. E. Schiel, "Development of an LCMS/MS peptide mapping protocol for the NISTmAb," Analytical and Bioanalytical Chemistry, vol. 410, no. 8, pp. 2111-2126, March 2018.   DOI
3 S. H. Han, J. S. Kim, Y. Lee, H. Choi, J. W. Kim, D. L. Na, E. G. Yang, M. H. Yu, D. Hwang, C. Lee, and I. Mook-Jung, "Both targeted mass spectrometry and flow sorting analysis methods detected the decreased serum apolipoprotein E level in Alzheimer's disease patients," Molecular & Cellular Proteomics, vol. 13, no. 2, pp. 407-419, February 2014.   DOI
4 J. S. Kim, H. S. Ahn, S. M. Cho, J. E. Lee, Y. Kim, and C. Lee, "Detection and quantification of plasma amyloid-β by selected reaction monitoring mass spectrometry," Analytica Chimica Acta, vol. 840, pp. 1-9, August 20 2014.   DOI
5 J. S. Kim, Y. Lee, M. Y. Lee, J. Shin, J. M. Han, E. G. Yang, M.-H. Yu, S. Kim, D. Hwang, and C. Lee, "Multiple reaction monitoring of multiple low-abundance transcription factors in whole lung cancer cell lysates," Journal of Proteome Research, vol. 12, no. 6, pp. 2582-2596, June 2013.   DOI
6 J. J. Kennedy, S. E. Abbatiello, K. Kim, P. Yan, J. R. Whiteaker, C. Lin, J. S. Kim, Y. Zhang, X. Wang, R. G. Ivey, L. Zhao, H. Min, Y. Lee, M.-H. Yu, E. G. Yang, C. Lee, P. Wang, H. Rodriguez, Y. Kim, S. A. Carr, and A. G. Paulovich, "Demonstrating the feasibility of large-scale development of standardized assays to quantify human proteins," Nature Methods, vol. 11, no. 2, pp. 149-155, February 2014.   DOI