• Title/Summary/Keyword: 인공 삽입물

Search Result 69, Processing Time 0.039 seconds

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

The Comparison of Motion Correction Methods in Myocardial Perfusion SPECT (심근관류 SPECT에서 움직임 보정 방법들의 비교)

  • Park, Jang-Won;Nam, Ki-Pyo;Lee, Hoon-Dong;Kim, Sung-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.28-32
    • /
    • 2014
  • Purpose Patient motion during myocardial perfusion SPECT can produce images that show visual artifacts and perfusion defects. This artifacts and defects remain a significant source of unsatisfactory myocardial perfusion SPECT. Motion correction has been developed as a way to correct and detect the patient motion for reducing artifacts and defects, and each motion correction uses different algorithm. We corrected simulated motion patterns with several motion correction methods and compared those images. Materials and Methods Phantom study was performed. The anthropomorphic torso phantom was made with equal counts from patient's body and simulated defect was added in myocardium phantom for to observe the change in defect. Vertical motion was intentionally generated by moving phantom downward in a returning pattern and in a non-returning pattern throughout the acquisition. In addition, Lateral motion was generated by moving phantom upward in a returning pattern and in a non-returning pattern. The simulated motion patterns were detected and corrected similarly to no-motion pattern image and QPS score, after Motion Detection and Correction Method (MDC), stasis, Hopkins method were applied. Results In phantom study, Changes of perfusion defect were shown in the anterior wall by the simulated phantom motions, and inferior wall's defect was found in some situations. The changes derived from motion were corrected by motion correction methods, but Hopkins and Stasis method showed visual artifact, and this visual artifact did not affect to perfusion score. Conclusion It was confirmed that motion correction method is possible to reduce the motion artifact and artifactual perfusion defect, through the apply on the phantom tests. Motion Detection and Correction Method (MDC) performed better than other method with polar map image and perfusion score result.

  • PDF

Arsenic removal from artificial arsenic water using CaAl-monosulfate and CaAl-ettringite (CaAl-monosulfate와 CaAl-ettringite를 이용한 인공비소폐수의 비소 제거 연구)

  • Shim, Jae-Ho;Kim, Ki-Baek;Choi, Won-Ho;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.26 no.1
    • /
    • pp.141-148
    • /
    • 2012
  • The objective of this study is to remove arsenate from artificially contaminated wastewater using CaAl-ettringite and CaAl-monosulfate which were synthesized in laboratory. The study was carried on the basis of solidification/stabilization of waste using cement. Monosulfate and ettringite are constituents of cement paste. The CaAl-ettringite has a chemical formula of $Ca_6Al_2O_6(SO_4)_3{\cdot}32H_2O$ and has a needle like morphology. Whereas CaAl-monosulfate $Ca_4Al_2O_6(SO_4){\cdot}12H_2O$ has layered double hydroxide structure (LDH) in which the mainlayer consists of Ca and Al and S as interlayer. Ettringite and monosulfate were synthesized by reaction of tricalcium aluminate and gypsum and hydrating this mixture at elevated temperature. The synthesized mineral were characterized by PXRD and FESEM to ensure purity. It was found that concentrations of As(V) in contaminated water were reduced from initial concentration of 1.335 mmol/L to 0.054 mmol/L and 0.300 mmol/L by CaAl-monosulfate and CaAl-ettringite respectively. The post experimental results of PXRD and FESEM analysis indicate that arsenate removal was by ion exchange.

Fistula of Ascending Aorta and Right Atrium Following Percutaneous Transcatheter Atrial Septal Defect Closure (경피적 카테타 심방중격결손 폐쇄술 후 발생한 상행 대동맥-우심방루)

  • Um Hong Gook;Seo Hong Joo;Kim Chong Whan;Kim Jun Seok;Lee Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.39 no.2 s.259
    • /
    • pp.150-153
    • /
    • 2006
  • Percutaneous transcatheter closure of atrial septal defects as a therapeutic alternative in appropriate patients provides superior cosmetic results, is less invasive, and allows for shorter hospital stays. Unfortunately, however, such percutaneous procedures can be associated with catastrophic procedure complications that may require immediate surgical intervention. We report a case of aorta-to-right atrial fistula two months after transcatheter occlusion of an atrial septal defect by an Amplatzer septal occluder. Revealed by dyspnea, palpitation and hemolysis, this complication needed an emergency surgical operation. The fistula between the noncoronary Valsalva sinus of the aorta and the right atrium was repaired. The atrial septal defect was closed by patch. The cause of this serious complication appears to be erosion into the aorta by the right atrial disk.

A study of user performed Virtual Space Storybook (사용자 참여 가상공간 스토리북 구현)

  • Park, Su Jin;Jung, Moon Ryul
    • Journal of the Korea Computer Graphics Society
    • /
    • v.25 no.3
    • /
    • pp.115-122
    • /
    • 2019
  • We In this study, We tested for artificial intelligence-based virtual space story books were planned. The proposed virtual space concept, a story book with the characteristics of Augmented Virtuality, was implemented Several steps are needed to proceed with the virtual space storybook's story. First, a user brings a real object in to virtual space and recognizes the real object with an artificial intelligence-based object-recognition software. Second, when object recognition progresses, the virtual 3D model is augmented in the virtual space, which is then inserted into the virtual space and rendered. Finally, software projected a virtual space storybook on the desk in which users can touch and select real-objects. This virtual space storybook was implemented using the new story-making technology by applying the virtual space concept. the Augmented Virtuality concept is to augment real objects based on virtual space. To confirm this we tested a user test using the virtual space storybook. the user seemed as if can the distinction between real objects and virtual images. Also very well and that understood the process of putting the real objects in virtual space.

The Effect of Total Patellectomy in the Prosthetic Replacement of Proximal Tibia (경골 근위부 종양에서 인공 삽입물 사용시 슬개골 전적출술이 관절기능 회복에 미치는 영향)

  • Park, Il-Hyung;Kim, Jae-Do;Ihn, Joo-Chul;Chun, In-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.2 no.1
    • /
    • pp.8-17
    • /
    • 1996
  • The purpose of this study is a comparative evaluation of range motion, especially extension deficit between the group of total patellectomy and that of intact patella, after reconstruction of the patellar tendon in the prosthetic replacement of a proximal tibia. Between 1990 and 1994, 15 patients who had a primary malignancy on proximal tibia were operated on. All patients were evaluated clinically and radiographically. Two patients were excluded because one had a deep infection treated with arthrodesis of the knee and the other was a composite allograft. The mean follow-up of the 13 patients was 27 months(15-47), including 10 osteosarcomas, 1 chondrosarcoma, 1 malignant fibrous histiocytoma and 1 malignant giant cell tumor. Eleven patients had a resection of the proximal tibia and 2 had an extracapsular total knee resection with distal femur. Reconstruction of the defect was done in 8 cases with a custom-made Link Endo-Model Total Rotation Knee Joint Prosthesis, and in 5 with How Medica Modular Resection System (HMRS). We used two methods to reconstruct the ligamentum patellae. Fixation of the patellar tendon to the prosthesis only with suturing and/or stapling(group SS) was done in 7. Transposition of gastrocnemius muscle to enhance fixation and to cover the prosthesis(group TG) was done in 6. Regardless of fixation methods, total patellectomy was done in 5 either to lengthen the patellar tendon or to make primary skin closure easier or for both. In 8 cases, patella was left intact or resurfaced with polyethylene prosthesis. Active extension was measured while the patient was in a sitting position. There is no statistically meaningful difference in terms of extension deficit (Wilcoxon rank test, p=0.8800) between patellectomy group and intact patella group, and between group of fixation only with suturing and that of gastrocnemius transposition. Two cases of extension deficit over 30 degree were seen in group SS and in the group of intact patella. Conclusively, total patellectomy could be an option without increasing the risk of extension deficit when primary skin closure is difficult or patellar tendon is a little bit short to be fixed. There is no rating in the Enneking system of functional evaluation that this finding into consideration.

  • PDF

Evaluation of Heat Exchange Efficiency and Applicability for Parallel U-type Cast-in-place Energy Pile (병렬 U형 현장타설 에너지파일의 열교환 효율 및 적용성 평가)

  • Park, Sangwoo;Kim, Byeongyeon;Sung, Chihun;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.361-375
    • /
    • 2015
  • An energy pile is one of the novel ground heat exchangers (GHEX's) that is a economical alternative to the conventional closed-loop vertical GHEX. The combined system of both a structural foundation and a GHEX contains a heat exchange pipe inside the pile foundation and allows a working fluid circulating through the pipe, inducing heat exchange with the ground formation. In this paper, a group of energy piles equipped with parallel U-type (5, 8 and 10 pairs) heat exchange pipes was constructed in a test-bed by fabricating in large-diameter cast-in-place concrete piles. In addition, a closed-loop vertical GHEX with 30m depth was constructed nearby to conduct in-situ thermal response tests (TRTs) and to compare with the thermal performance of the cast-in-place energy piles. A series of thermal performance tests was carried out with application of an artificial cooling and heating load to evaluate the heat exchange rate of energy piles. The applicability of cast-in-place energy piles was evaluated by comparing the relative heat exchange efficiency and heat exchange rate with preceding studies. Finally, it is concluded that the cast-in-place energy piles constructed in the test-bed demonstrate effective and stable thermal performance compared with the other types of GHEX.

Evaluation of Debonding Defects in Railway Concrete Slabs Using Shear Wave Tomography (전단파 토모그래피를 활용한 철도 콘크리트 궤도 슬래브 층분리 결함 평가)

  • Lee, Jin-Wook;Kee, Seong-Hoon;Lee, Kang Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.11-20
    • /
    • 2022
  • The main purpose of this study is to investigate the applicability of the shear wave tomography technology as a non-destructive testing method to evaluate the debonding between the track concrete layer (TCL) and the hydraulically stabilized based course (HSB) of concrete slab tracks for the Korea high-speed railway system. A commercially available multi-channel shear wave measurement device (MIRA) is used to evaluate debonding defects in full-scaled mock-up test specimen that was designed and constructed according to the Rheda 200 system. A part of the mock-up specimen includes two artificial debonding defects with a length and a width of 400mm and thicknesses of 5mm and 10mm, respectively. The tomography images obtained by a MIRA on the surface of the concrete specimens are effective for visualizing the debonding defects in concrete. In this study, a simple image processing method is proposed to suppress the noisy signals reflected from the embedded items (reinforcing steel, precast sleeper, insert, etc.) in TCL, which significantly improves the readability of debonding defects in shear wave tomography images. Results show that debonding maps constructed in this study are effective for visualizing the spatial distribution and the depths of the debondiing defects in the railway concrete slab specimen.

Induction of Sexual Maturation in Female Eels (Anguilla japonica) Using an Osmotic Pump (Osmotic pump를 이용한 암컷 뱀장어(Anguilla japonica)의 성성숙 유도)

  • Kim, Jung-Hyun;Kim, Dae-Geun;Kim, Hyo-Won;Lee, Bae-Ik;Kim, Shin-Kwon;Jun, Je-cheon;Myeong, Jeong-In;Kim, Dae-Jung
    • Journal of Life Science
    • /
    • v.27 no.10
    • /
    • pp.1097-1103
    • /
    • 2017
  • For the artificial induction of the sexual maturation of Anguilla japonica, salmon pituitary extract (SPE) is continuously injected into females, and the eggs obtained from artificial sexual maturation are artificially fertilized with sperms and hatched. However, repeated injection of SPE in the abdominal cavity causes tremendous stress in females, which may prevent their complete sexual maturation and reduce the immune system function, ultimately resulting in death. In addition, the poor quality of the ovulated eggs can reduce the hatching and survival rate of larvae. In the present study, sexual maturation of females was induced by inserting an osmotic (OS) pump containing hormone analogs known to effectively induce sexual maturation into the abdominal cavity of female eels, and the effect of the OS pump on the induced sexual maturation was investigated. Our study results showed that the gonadosomatic index (GSI) was significantly higher in the fish subjected to SPE injection than those subjected to human chorionic gonadotropin (hCG), gonadotropin-releasing hormone analog (GnRHa), and methyl testosterone (MT) injections, either separately or in combination. In addition, a histological analysis showed that the oocytes in the SPE OS pump groups were more mature (entered the nuclear shift stage) than those in the other groups. These results suggest that an osmotic pump containing hormone analogs can be used to induce sexual maturation in female A. japonica artificially.