• Title/Summary/Keyword: 인공물

Search Result 1,875, Processing Time 0.029 seconds

Comparison of Metal Artifact Reduction Algorithms in Patients with Hip Prostheses: Virtual Monoenergetic Images vs. Orthopedic Metal Artifact Reduction (고관절 인공치환술 환자에서 금속 인공물 감소 방법의 비교: 가상 단일에너지영상 대 금속 인공물 감소기법)

  • Hye Jin Yoo;Sung Hwan Hong;Ja-Young Choi;Hee Dong Chae
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.6
    • /
    • pp.1286-1297
    • /
    • 2022
  • Purpose To assess the usefulness of various metal artifact reduction (MAR) methods in patients with hip prostheses. Materials and Methods This retrospective study included 47 consecutive patients who underwent hip arthroplasty and dual-energy CT. Conventional polyenergetic image (CI), orthopedic-MAR (OMAR), and virtual monoenergetic image (VMI, 50-200 keV) were tested for MAR. Quantitative analysis was performed in seven regions around the prostheses. Qualitative assessments included evaluation of the degree of artifacts and the presence of secondary artifacts. Results The lowest amount of image noise was observed in the O-MAR, followed by the VMI. O-MAR also showed the lowest artifact index, followed by high-keV VMI in the range of 120-200 keV (soft tissue) or 200 keV (bone). O-MAR had the highest contrast-to-noise ratio (CNR) in regions with severe hypodense artifacts, while VMI had the highest CNR in other regions, including the periprosthetic bone. On assessment of the CI of pelvic soft tissues, VMI showed a higher structural similarity than O-MAR. Upon qualitative analysis, metal artifacts were significantly reduced in O-MAR, followed by that in VMI, while secondary artifacts were the most frequently found in the O-MAR (p < 0.001). Conclusion O-MAR is the best technique for severe MAR, but it can generate secondary artifacts. VMI at high keV can be advantageous for evaluating periprosthetic bone.

Reduction of Artifacts in Magnetic Resonance Imaging with Diamagnetic Substance (반자성 물질을 이용한 자기공명영상검사에서의 인공물 감소)

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.581-588
    • /
    • 2019
  • MRI is superior when contrasted to help the organization generate artifacts resolution, but also affect the diagnosis and create a image that can not be read. Metal is inserted into the tooth, it is necessary to often be inhibited in imaging by causing the geometric distortion due to the majority and if the difference between the magnetic susceptibility of a ferromagnetic material or paramagnetic reducing them. The purpose of this study is to conduct a metal artefact in accordance with the analysis using a diamagnetic material. The magnetic material include a wire for the orthodontic bracket and a stainless steel was used as a diamagnetic material was used copper, zinc, bismuth. Testing equipment is sequenced using 1.5T, 3T was used was measured using a SE, TSE, GE, EPI. A self-produced phantom material was used for agarose gel (10%) to a uniform signal artifacts causing materials are stainless steel were tested by placing in the center of the phantom and cover inspection of the positive cube diamagnetic material of 10mm each length.After a measurement artefact artifact zone settings area was calculated using the Wand tool After setting the Low Threshold value of 10 in the image obtained by subtracting images, including magnetic material from a pure tool phantom images using Image J. Metal artifacts occur in stainless steel metal artifact reduction was greatest in the image with the bismuth diamagnetic materials of copper and zinc is slightly reduced, but the difference in degree will not greater. The reason for this is thought to be due to hayeotgi offset most of the susceptibility in bismuth diamagnetic susceptibility of most small ferromagnetic. Most came with less artifacts in image of bismuth in both 1.5T and 3T. Sequence-specific artifact reduction was most reduced artifacts from the TSE 1.5T 3T was reduced in the most artifacts from SE. Signal-to-noise ratio was the lowest SNR is low, appears in the implant, the 1.5T was the Implant + Bi Cu and Zn showed similar results to each other. Therefore, the results of artifacts variation of diamagnetic material, magnetic susceptibility (${\chi}$) is the most this shows the reduced aspect lower than the implant artificial metal artifacts criteria in the video using low bismuth susceptibility to low material the more metal artifacts It was found that the decrease. Therefore, based on the study on the increase, the metal artifacts reduction for the whole, as well as dental prosthesis future orthodontic materials in a way that can even reduce the artifact does not appear which has been pointed out as a disadvantage of the solutions of conventional metal artifact It is considered to be material.

Clinical Apply of Dual Energy CT (kVp switching) : A Novel Approach for MAR(Metal Artifact Reduction) Method (듀얼에너지 CT(kvp switching)의 임상 적용: MAR(Metal Artifact Reduction) 알고리즘의 적용)

  • Kim, Myeong-Seong;Jeong, Jong-Seong;Kim, Myeong-Goo
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.2
    • /
    • pp.79-85
    • /
    • 2011
  • OThe purpose of this article was to measure and compare the value of the metal artifact reduction (MAR) algorithm by Dual energy(kVp switching) CT (Computed Tomography) for non using MAR and we introduced new variable Dual energy CT applications through a clinical scan. The used equipment was GE Discovery 750HD with Dual-Energy system(kVp switching). CT scan was performed on the neck and abdomen area subject for patients. Studies were from Dec 20 2010 to Feb 10 2011 and included 25 subject patients with prosthesis. We were measured the HU (Hounsfield Unit) and noise value at metal artifact appear(focal loss of signal and white streak artifact area) according to the using MAR algorithm. Statistical analyses were performed using the paired sample t-test. In patient subject case, the statistical difference of showing HU was p=0.01 and p=0.04 respectively. At maximum black hole artifact area and white streak artifact area according to the using MAR algorithm. However noise was p=0.05 and p=0.04 respectively; and not the affected black hole and white streak artifact area. Dual Energy CT with the MAR algorithm technique is useful reduce metal artifacts and could improve the diagnostic value in the diagnostic image evaluation of metallic implants area.

MRI Artifacts and Reducing Techniques

  • 강해진
    • Proceedings of the KSMRM Conference
    • /
    • 1999.04a
    • /
    • pp.34-42
    • /
    • 1999
  • 의료영상에서 인공물(Artifacts) 이라 함은 영상이 얻어지는 신체부위와 아무런 관련이 없으나 얻어진 영상에는 마치 영상의 일부분으로 나타나는 모든 것을 가리킨다. 따라서 영상에서 이들 인공물들은 실제 조직의 해부학적인 구조를 나타내지 않으므로 영상 판독에 영향을 주어 잘못된 진단을 초래할 수도 있다. 그러나 MR 영상이 가능한 이래로 새로운 여러 종류의 MR 인공물들이 많이 발견 되었으나 다행스럽게도 거의 모든 MR 인공물들은 쉽게 설명이 가능하며, 따라서 이들 인공물들에 의한 진단 오류의 가능성은 매우 희박한 실정이다. 그러나 새로운 영상방법이나 혹은 새로운 펄스대열이 계속 고안됨에 따라 새로운 종류의 인 공물들이 생겨날 가능성은 항상 존재하고 있다. 지금까지 알려진 여러 MR 인공물들은 그 생겨난 원인에 따라 다음과 같이 크게 세 가지로 분류가 가능하다. I. Motion Artifacts 1. Voluntary motion 2. Involuntary motion 1) Bowel Peristalsis 2) Respiration 3) Cardiac and vessel pulsation 4) Swallowing 3. Fluid motion 1) Blood flow 2) Cerebrospinal fluid flow II. Reconstruction Artifacts 1. Aliasing 2. Partial volume averaging 3. Truncation (Ringing) 4. Central point III. Magnetic and RF Field Related Artifacts 1. Chemical shift 1) First kind 2) Second kind 2. Susceptibility 1) Dental 2) Metal 3. Magic angle 4. Zipper 5. Bad data point 6. RF field inhomogeneity 7. Magnetic field inhomogeneity 8. Eddy current 9. slice overlapping 10. Zebra 11. RF overflow

  • PDF

Scale-invariant man-made structure extraction algorithm (크기에 강인한 인공물 축출 방법)

  • Son, Kil-Ho;Kim, Sang-Hee;Lee, Yong-Woong
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06c
    • /
    • pp.539-544
    • /
    • 2008
  • 이 논문에서 크기의 변화에 강인한 인공물 축출 알고리듬을 제안한다. 인공물은 크기 및 카메라 센서의 특성에 따라 영상에 다양한 크기로 나타난다. 이 논문은 이러한 크기 변화에 강인한 인공물 축출 방법을 제안한다. 우선 LoG(Laplacian of Gaussian)를 이용하여 최적의 크기를 찾아낸다. 이를 이용하여 우리는 이웃한 정보를 포함할 수 있는 MAP-MRF(Maximum A Posterior-Markov Random Field) 레이블링(Labeling) 방법을 기반으로 인공물 축출을 위한 비용함수를 제안하였다. 인공물은 서로 근처에 존재하기 때문이다. 여기서 정보 비용함수(Data cost function)는 방향 히스토그램(Orientation histogram)을 이용하여 정의하였고, 스무딩 비용함수(Smoothing cost function)는 ICM(Iterated Conditional Modes)을 이용하여 정의한다. 최종적으로 이 알고리듬을 위성영상에 적용하여 알고리듬의 성능을 증명한다.

  • PDF

A study on the sedimentation in the vicinity of the groins near harbor (항만 인근 해안의 인공 구조물 주변 퇴적 작용 분석)

  • Kim Hye-Jin
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.06b
    • /
    • pp.179-183
    • /
    • 2006
  • As there are many human activities in the coastal regions, various facilities and coastal engineering structures for protecting beach have been built. Dredging work, reclamation and harbor construction have caused the topography of sea floor to change rapidly. So sedimentation in the vicinity of the groins has get dull and the serious aspects sometimes turn up. Analyzing the surface sediments with transport vector model is one of the good methods to understand the sedimentation in the vicinity of the groins. I analyzed the transport vector of the surface sediments in the vicinity of the groins at the region where serious beach erosion happens near Pohang harbor.

  • PDF

Consideration on Methods to Suppress Metal Artifacts Caused by Spinal Fusion during Spine MRI Study (척추 MRI 검사 시 척추 유합술로 인한 금속 인공물 억제 방법에 대한 고찰)

  • Se-Jong Yoo;Soon-Yong Kwon;Seong-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1123-1131
    • /
    • 2023
  • This study aimed to present a method to effectively suppress metal artifacts caused by spinal fusion surgery during spinal MRI study. For this purpose, a phantom made of spinal surgery screws was created to reproduce the metal artifact. Then, images were acquired with 1.5T and 3.0T MRI to evaluate changes in metal artifacts according to magnetic field strength. In addition, metal artifacts were evaluated by increasing the receive bandwidth to 200, 400 and 800 Hz/PX. As a result, metal artifacts occurring in images obtained from the 1.5T MRI decreased by approximately 52.2% compared to images obtained from the 3.0T MRI, showing a significant difference (p<0.05). In particular, the signal loss and signal pile up areas were reduced by approximately 52.81% and 42.71%, respectively, showing a significant effect in suppressing metal artifacts. On the other hand, when images were acquired while increasing the receive bandwidth from 200 to 800 Hz/PX, there was no significant effect, with a decrease of up to 8.93% for the 1.5T MRI and up to 10.98% for the 3.0T MRI (p>0.05). As a result of this study, increasing the receive bandwidth reduced signal loss and reduced some metal artifacts, but did not have a significant effect because it did not suppress signal pile up. However, when the magnetic field strength was reduced from 3.0T to 1.5T, signal loss and signal pile up were greatly reduced, effectively improving the metal artifact. Therefore, in order to suppress metal artifacts caused by spinal fusion surgery, study using a low magnetic field MRI can be said to be the most effective method.

Evaluation of artifacts around the breast expander according to magnetic field strength (자장의 세기에 따른 유방 확장기 주위의 인공물 평가)

  • Jung, Dong- Il;Kim, Jae-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.9
    • /
    • pp.1144-1149
    • /
    • 2020
  • The magnetic valve of the breast tissue expander generates imaging artifacts during MRI examination, so MRI examination is limited. To evaluate the effect of imaging artifacts on the diagnosis area for patients with breast tissue expander who need MRI examination. Imaging artifacts were measured using self-made phantoms and actual clinical conditions. Imaging artifacts were measured differently depending on the environment of 1.5 Tesla and 3.0 Tesla, and the effects of imaging artifacts were less in the C-spine and L-spine tests. If MRI due to breast cancer metastasis is absolutely necessary, head & neck examination and L-spine can be examined mainly at 1.5 Tesla, but some sequences may cause distortion due to image artifacts. In terms of safety, MRI scans of patients with breast tissue expanders can be performed conditionally at 1.5T, avoiding 3.0T.

Application of the Artificial Neural Network to Damage Evaluations of a RC Mock-up Structure (구조물 손상평가를 위한 인공신경망의 RC Mock-up 적용 평가)

  • Kim, Ji-Young;Kim, Ju-Yeon;Yu, Eun-Jong;Kim, Dae-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2010.04a
    • /
    • pp.687-691
    • /
    • 2010
  • 구조물의 건전도를 평가하기 위해 상시 구조물 계측을 이용한 Structural Health Monitoring (SHM) 시스템을 적용하게 된다. SHM 시스템의 궁극적 목적은 계측된 데이터를 이용하여 구조물의 손상위치 및 손상정도를 분석하여 거주자에게 유지관리정보와 대처요령 신속하게 제공하는 것이다. 따라서 본 연구에서는 구조물의 손상탐지를 위해 인공신경망(Artificial Neural Network)을 도입한 알고리즘을 수립하고, 이를 3층 실대 RC Mock-up 구조물에 적용하여 성능을 평가하였다. 먼저 인공신경망의 학습을 위해 구조해석 프로그램을 이용하여 구조물의 손상에 따른 동적특성 변화 데이터베이스를 구축하였다. 그리고 학습된 인공망에 실제 구조물에서 추출한 동특성의 변화를 입력하여 손상탐지를 실시하였다. 이를 통해 인공신경망의 학습방법, 학습데이터의 정규화 방법 등을 규명하고 인공신경망을 이용한 손상탐지의 효과를 분석하였다.

  • PDF

Experimental Study of Chemical Shift Artifacts at 1.5T and 3.0T MRI using Gradient Echo Pulse Sequence (GE 펄스시퀀스을 이용한 1.5T와 3.0T MRI의 화학적 이동 인공물의 실험적 연구)

  • Cheol, Kweon Dae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.531-537
    • /
    • 2016
  • An experimental study was to use the parameter to determine the MRI artifact of chemical shift that occurs in water and fats. Scanning the image according to the encoding parameter and the bandwidth and change in 1.5T and 3.0T MRI to the SNR, we compared the CNR. In the image was confirmed that the occurrence of artefacts in the chemical shift of the water and oil. 3.0T more image artifacts in the 1.5T was confirmed that the relatively reduced. The width of the bandwidth it could be confirmed that according to the honeycombs artifacts decrease. Therefore, in order to reduce the artifacts in the MRI scan of the chemical shift runners weak field strength, is thought to be appropriate to widen the width of the bandwidth.