• Title/Summary/Keyword: 이중 루프

Search Result 114, Processing Time 0.046 seconds

Design of bidirectional DC-DC converter controller of Using a supercapacitor energy storage (슈퍼캐패시터 에너지 저장장치의 양방향 DC-DC 컨버터 제어기 설계)

  • Im, Jae-Kwan;Son, Kyoung-Min;Kwon, Kyoung-Min;Choi, Jae-Ho;Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.161-163
    • /
    • 2009
  • 본 논문은 차세대 에너지 저장장치로 각광받는 슈퍼커패시터를 이용한 양방향 DC-DC컨버터의 구성 및 빠른 동특성을 갖는 이중 루프 PI제어기 설계를 제시하였다. 제어기는 초기 슈퍼캐패시터의 충전을 위한 정전류 제어기와 초기 충전 이후에 동작을 개시하는 전력제어기를 구성하였다. 구성된 제어기는 PSIM을 이용한 시뮬레이션을 통하여 검증하였다.

  • PDF

Double loop Inverter Controller Design satisfied with Time Specification (시간응답을 만족하는 인버터 이중루프 제어기 설계)

  • Lee, Jin-Mok;Noh, Se-Jin;Son, Kyoung-Min;Lee, Jae-Moon;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.914-915
    • /
    • 2008
  • Generally, inverter controller for UPS or renewable energy system have been used double loop PI controller, But it is hard to get controller gains for double loop controller because it is high order. Futhermore, to consider time specification is difficult too. This paper presents the way how to make double PI loop controller for inverter satisfied with time specification using CRA method and verify efficiency of it using Matlab and Psim.

  • PDF

A Protection Scheme of Interconnected Bus for Distributed Generators (분산전원 연계모선 보호방식)

  • Seo, Woo-Seok;Kim, Byung-Sam;Park, Eun-young;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.565-566
    • /
    • 2015
  • 본 논문에서는 풍력발전 단지를 전력계통에 연계시키는 경우 연계모선의 보호를 위한 방향지락 과전류 계전 알고리즘과 차동전류를 이용한 과전류 계전 알고리즘를 제안하였다. 분산전원은 동기기와 전력변환기로 구성되며, 풍력발전단지는 이중모선으로 연계되는 루프 계통으로 모델링하였다. 각 계전 알고리즘은 모선의 내부고장 및 외부고장을 판별하여 내부고장 발생 시 고장구간을 신속, 정확히 개방하여 고장 구간을 최소화한다. 제안한 계전 알고리즘은 PSCAD/EMTDC를 통해 검증하였다.

  • PDF

Design of Bidirectional DC-DC converter for Lithium Battery Charging/Discharging Characteristics (리튬 배터리 충방전 특성을 고려한 양방향 DC/DC 컨버터 설계)

  • Im, Jae-Kwan;Lim, Deok-Young;Choi, Jae-Ho;Kwon, Kyoung-Min;Chung, Gyo-Bum
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.475-476
    • /
    • 2010
  • 본 논문은 에너지 저장장치로 각광받는 Li 배터리를 이용한 양방향 DC-DC컨버터의 구성 및 빠른 통특성을 갖는 이중 루프 PI제어기 설계를 제시하였다. 제어기는 초기 충전을 위한 정전류 제어기와 초기 충전 이후에 동작을 개시하는 전력제어기를 구성하였다. 배터리 모델링 및 양방향 DC-DC 컨버터용 제어기는 PSIM을 이용한 시뮬레이션을 통하여 검증하였으며, 그 타당성을 실험을 통하여 확인하였다.

  • PDF

Dual-band Open Loop Antenna using Strip-conductor for an RFID Reader (RFID 리더용 이중대역 도체스트립 개방루프 안테나)

  • Lim, Jung-Hyun;Kang, Bong-Soo;Kim, Ji-Yoon;Kim, Heung-Soo;Yang, Doo-Yeong
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.63-64
    • /
    • 2006
  • In this paper, the open loop antenna using a strip-conductor for an RFID reader at dual-band frequency(910MHz, 2.45GHz) is proposed. The impedance is matched by varying the antenna parameters such as the length of strip-conductor and the gap of between two strip-conductors. Return loss and gain of designed antenna are -11.919dB, 2.5dBi at 910MHz, and -15.766dB, 5.65dBi at 2.45GHz, respectively.

  • PDF

A Dual-compensated Charge Pump for Reducing the Reference Spurs of a Phase Locked Loop (위상 고정 루프의 기준 스퍼를 감소시키기 위한 이중 보상 방식 전하 펌프)

  • Lee, Dong-Keon;Lee, Jeong-Kwang;Jeong, Hang-Geun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.2
    • /
    • pp.465-470
    • /
    • 2010
  • The charge pump in a phase-locked loop is a key block in determining reference spurs of the VCO output signal. To reduce reference spurs, the current mismatch in the charge pump must be minimized. This paper presents a dual compensation method to reduce the current mismatch. The proposed charge pump and PLL were realized in a $0.18{\mu}m$ CMOS process. Measured current matching characteristics were achieved with less than 1.4% difference and with the current variation of 3.8% in the pump current over the charge pump output voltage range of 0.35-1.35V at 1.8V. The reference spur of the PLL based on the proposed charge pump was measured to be -71dBc.

A Study on the Implementation of Frequency Hopping Binary Noncohrent FSK Tranceiver (주파수 도약2진 비코히어런트 FSK송수신기 실현에 관한 연구)

  • 박영철;김재형;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.3
    • /
    • pp.260-268
    • /
    • 1990
  • This paper investigates the design of a frequency hopping FSK tranceiver system, where the system enhancements are made in the following three aspects: dual frequency synthesiszation for the increased hopping rate, linearization of VCO gain in PLL to improve BFSK modulation characteristics, and fast code synchronization by the matched filter method.

  • PDF

Research of Reliability Evaluation for Distribution System via ANP (ANP에 의한 배전계통 신뢰도의 평가에 관한 연구)

  • Lee, Buhm;Choi, S.K.;Kim, Y.H.;Cho, J.H.;Nam, K.W.;Moon, J.H.
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.113-118
    • /
    • 1999
  • 배전계통의 신뢰도를 계산하는 기법은 Roy Billinton 등에 의해 연구되어 왔으며, 이중 방사상계통에 대한 신뢰도는 PSS/U와 같은 상용소프트웨어를 사용하여 용이하게 계산할 수 있단. 그러나, 루프나 병렬회로를 포함하는 배전계통에 대한 신뢰도는 개개의 계통에 대한 모델을 각기 구성하여야하는 어려움이 있어, 아직까지 일반화되지 못하고 있다.(중략)

  • PDF

The Design and Control of Bi-directional DC-DC Converter for a Fuel Cell Power System (연료전지 발전 시스템을 위한 양방향 DC-DC 컨버터 설계 및 제어)

  • Kim, Seung-Min;Yang, Seung-Dae;Choy, Ick;Choi, Ju-Yeop;Lee, Sang-Cheol;Lee, Dong-Ha
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.528-529
    • /
    • 2012
  • 연료전지는 매우 늦은 응답속도를 가지므로 부하 증가시 Li-Ion 배터리나 슈퍼 커패시터 같은 별도의 에너지 저장장치로부터 필요한 전류를 공급받도록 구성되는데 이들 사이에서 전력전달을 위해 DC-DC 컨버터가 필수적으로 요구된다. 본 논문에서는 상태평균화 기법과 PWM 스위치 모델을 사용하여 DC-DC 컨버터를 해석하고 시뮬레이션 하였다. 또한 배터리 등가회로를 구성해서 배터리 등가 임피던스를 고려한 이중루프 제어기를 설계하고 정전류/정전압 충전모드 시뮬레이션을 통해 효과를 확인하였다.

  • PDF

Pressure Control of Electro-Hydraulic Variable Displacement Pump Using Genetic Algorithms (GA를 이용한 전기유압식 가변펌프의 압력제어)

  • 안경관;현장환;조용래;오범승
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.48-55
    • /
    • 2004
  • This study presents a genetic algorithm-based method fur optimizing control parameters in the pressure control of electro-hydraulic pump with variable displacement. Genetic algorithms are general-purpose optimization methods based on natural evolution and genetics and search the optimal control parameters maximizing a measure that evaluates the performance of a system. Four control gains of the PI-PD cascade controller for an electro-hydraulic pressure control system are optimized using a genetic algorithm in the experiment. Optimized gains are confirmed by inspecting the fitness distribution which represents system performance in gain spaces. It is shown that genetic algorithm is an efficient scheme in optimizing control parameters of the pressure control of electro-hydraulic pump with variable displacement.