• Title/Summary/Keyword: 이중 관

Search Result 525, Processing Time 0.027 seconds

The study of developing the freezing seal isolation method for the pre insulated heat transfer pipe (이중보온 열수송관에 대한 동결차수공법개발에 관한 연구)

  • You, Byounghee;Ahn, Changkoo;Kim, Woocheol;Shin, Ikho
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.105-112
    • /
    • 2017
  • A lot of piping systems have been used from nuclear power systems to water supply systems. The maintenance of the piping systems is needed to ensure proper operation of the piping systems. Failure of the large pipe systems especially such as KDHC(Korea District Heating Corporation) can be a matter directly related to the enterprise productivity and profitability. It can also lead to very important issues in promoting public safety and convenience. Therefore a method of quick and safety repairs have been emerged as the most important problem. In this study, freezing seal isolation method using liquid nitrogen cryogenic refrigerant was developed for the maintenance of a pre insulated heat transport pipe of KDHC with a diameter of 300 mm. In this study, by employing computational analysis techniques we performed the flow and heat transfer analysis for the targeted pre insulated heat transfer pipe and freezing seal jacket(ice-Plug) and have selected for optimal system. The detailed design model based on the results of the computational analysis finally was produced. A laboratory-scale test apparatus were designed and the freezing seal isolation self-test carried out. Also the performance assessment tests in the test bed of KDHC were carried out for on-site application.

Mechanical Performance Evaluation of a Top End Piece for Dual Cooled Fuels (이중냉각 핵연료 상단고정체의 기계적 성능평가)

  • Kim, Jae-Yong;Yoon, Kyung-Ho;Kim, Hyung-Kyu;Choi, Woo-Seok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.4
    • /
    • pp.417-424
    • /
    • 2011
  • A fuel assembly consists of five major components, i.e., a top end piece (TEP), a bottom end piece (BEP), spacer grids (SGs), guide tubes (GTs) and an instrumentation tube (IT); in addition, it also includes fuel rods (FRs). The TEP/BEP should satisfy stress intensity limits according to the conditions A and B of ASME, Section III, Division 1-Subsection NB. In a dual-cooled fuel assembly, the array and position of fuel rods are different from those in a conventional PWR fuel assembly; these changes are necessary for achieving power uprating. The flow plates of the TEP and BEP have to be modified accordingly. The pattern and shape of the flow holes were newly designed. To verify the strength compatibility, the Tresca stress limit according to the ASME code was investigated in the case of an axial load of 22.241 kN. In this paper, the stress linearization procedure for strength evaluation of a newly designed TEP is presented.

Development and Estimation of Double-Drainage System in Urban Areas against Localized High-Intensity Rainfall (집중호우에 대비한 도시지역 이중배수 시스템 개발 및 평가)

  • Kim, Tae Beom;Kim, Yong In;Kim, Yong In;Yang, Jeong-Seok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.362-366
    • /
    • 2015
  • 지난 백여 년 동안 인간은 과거의 그 어떤 선조들도 이루지 못한 지식과 기술의 발전을 통해 고도로 산업화된 사회를 이루었지만, 전 지구적으로 기후변화라는 부차적인 결과와 현실에 직면하고 있다. 이상기후 현상은 전지구 규모뿐만 아니라 일정한 소규모 지역에서도 관측되고 있으며, 국내에서는 특히 특정 지역에 국한되어 단시간에 발생하는 집중호우가 대표적인 사례이다. 현재까지 집중호우 발생 지역과 정도를 예측하기란 불가능한 상태이며, 산업화와 도시화가 진행될수록 그 피해는 더욱 증가할 것으로 예상된다. 따라서 집중호우에 대비한 도시 배수 시스템을 재점검할 필요가 있으며, 기존의 배수시설을 대체할 만큼 효율적인 배수구조물의 개발이 시급하다. 기존 도시지역의 측구형 수로관에는 마감불량, 정밀시공의 어려움, 이물질의 누적과 물고임, 노출로 인한 파손, 포장층 침투수 배수문제 등 많은 문제점들이 존재한다. 따라서 본 연구에서는 기존의 측구형 수로관의 단점을 보완하는 더욱 효율적인 집수정을 개발하고자 하였다. 집수정을 덮고 있는 포장층 상부면을 따라 흐르는 표면수를 처리할 뿐만 아니라, 포장층 내부로 스며드는 침투수를 처리 가능하도록 구조체 상부에 침투수 유입공을 설치하여, 표면수와 침투수를 동시에 고려하는 이중배수 시스템을 구성하였다. 본 연구에서 개발하는 집수정 구조체는 침투수에 의한 도로 및 구조체의 내구성 감소 및 겨울철 동파 현상을 방지할 수 있을 뿐 아니라, 단순공정, 시공성 향상, 유지비용절감 등 기존 배수 시스템과 비교해 많은 장점을 내포하고 있다. 본 연구에서 개발하는 이중배수 집수정의 효율 및 배수능력 평가를 위해서는 기존의 구조체와 차별되는 침투수 유입공에 대한 평가가 선행되어야 한다. 이를 위해서 침투수 유입공에 대한 실내 실험 장치를 구축하였으며, 반복 실험을 통해 침투수 유입공을 통한 배출 능력을 평가하고자 하였다. 또한 실험 결과를 바탕으로 구조체의 효능을 결정짓는 기준을 제시하고자 한다.

  • PDF

Isolating Subsystems by Valves in a Water Distribution System and Evaluating the System Performance (상수관망에서의 밸브에 의한 관의 부분적 격리와 상수관망의 효율성 평가)

  • Jun, Hwan-Don
    • Journal of Korea Water Resources Association
    • /
    • v.38 no.7 s.156
    • /
    • pp.585-593
    • /
    • 2005
  • Recent concerns regarding protecting, identifying, isolating, redundant routing and dewatering of subsystems of water distribution networks have led to the realization of the importance of valves in these systems. Valves serve two purposes namely, flow and pressure control and isolating subsystems due to breakage or contaminant containment. In this paper, valves are considered from the point of view of subsystem isolation. When a water main is required to be closed, it may be in general necessary to close several other pipes in addition to the broken pipe itself depending on the distribution of adjacent valves. This set of pipes is defined as a segment. In this paper a segment analysis for isolating pipes is present and based on the segment analysis, we suggested the Valve Importance Index and the 7 performance indicators to evaluate the system performance. The suggested methodology is applied to a real network to verify the applicability of the methodology.

Thermal-flow Characteristics of Magnetic Fluid for Concentric Annuli Under Fixing Magnetic Field Using Visualization Technique (가시화기법을 이용한 고정자장에서 이중원관내 자성유체의 열유동 특성에 관한 연구)

  • Kim, Hyung-Jin;Seo, Jae-Hyeong;Kim, Dae-Wan;Lee, Moo-Yeon;Seo, Lee-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.1
    • /
    • pp.26-30
    • /
    • 2013
  • This article is experimentally to investigate thermal-flow characteristics of the magnetic fluid for concentric annuli under externally fixed magnetic fields using visualization technique. Temperatures of the inner tube and outer tube in the tested concentric annuli were constantly maintained at both $30^{\circ}C$ and $25^{\circ}C$ and the middle tube was filled with the magnetic fluid. Magnetic field was uniformly applied using 4 permanent magnets at 4 directions of the concentric annuli. As a result, the thermal-flow characteristics of the magnetic fluid for concentric annuli could be controlled by directions of the external magnetic fields.

Thermal Efficiency Analysis of the Conical Solar Concentrator According to the Black Coating of Absorber (흡수기 도색 여부에 따른 원추형 집광기 집열효율 분석)

  • Hwang, Seong Geun;Na, Mun Soo;Woo, Sung Jae;Lee, Joo Hee;Lee, Gwi Hyun
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.125-125
    • /
    • 2017
  • 본 연구에서 원추형 태양열 집광기의 흡수관 표면의 흑색 도색 여부에 따른 효율분석을 수행하였다. 원추형 집광기 시스템은 열 손실 최소화 및 집광비가 우수한 $45^{\circ}$의 원추각을 갖는 원추형 집광기를 설계 및 제작하였다. 원추형 태양열 집광시스템은 열매체 축열을 위한 온도센서가 내장된 축열조와 태양에너지를 집열시키는 원추형 집광기, 유량측정을 위한 유량계, 열매체의 강제순환을 위한 펌프로 구성되어있다. 또한 지속적인 태양추적을 위해 2축 태양 추적 장치를 설치하였다. 흡수관은 원추형 집광기의 중심부에 설비되었으며, 열매체의 순환을 위해 이중 열교환기 구조로 제작되었다. 흡수관의 길이는 열 손실을 최소화하기 위하여 집광기의 높이와 동일하게 설계하였다. 원추형 집광시스템의 작동유체인 물은 펌프에 의해 흡수관과 축열조를 강제순환 하게되고, 용량이 70L인 축열조에 흡수관으로부터 흡수된 태양 복사열이 저장된다. 원추형 집광시스템의 성능실험은 청명한 날 유량 2L/min, 4L/min, 6L/min에 대해 수행되었으며, 집열효율을 계산하여 비교 및 분석하였다. 흑색으로 도색된 흡수기를 부착한 원추형 집광시스템의 집열효율은 82.25%로 나타났으며, 무 도색 흡수관을 갖는 원추형 집광시스템은 73.26%의 집열효율을 나타내었다. 따라서 본 연구를 통해 흡수관 표면의 흑색 도색이 원추형 집광시스템의 집열효율에 큰 영향을 미친다는 것을 알 수 있었다.

  • PDF

Development of Design Program for CFFT Structure (CFFT구조의 설계프로그램 개발)

  • Choi, Young-Min;Hwang, Yoon-Koog;Lee, Young-Ho;Lee, Jung-Howan;Kim, Dong-Chan
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2009.04a
    • /
    • pp.549-552
    • /
    • 2009
  • 본 논문에서는 재료적 성능이 우수하며 경량재료로서 최근 건설구조물에 활용하고자 하는 연구가 활발히 진행되고 있는 섬유보강재료(FRP : Fiber Reinforced Polymer)를 이용한 합성구조인 CFFT(Concrete Filled FRP Tube)의 설계프로그램을 개발하여 제안하고자 하였다. 먼저, CFFT구조는 FRP관에 의해 철근콘크리트가 구속되는 구조로서 기둥과 같이 축력이 도입되는 경우 포아송효과에 의한 변형을 FRP관이 구속효과를 줌으로써 콘크리트의 역학적 거동을 개선하게 되는데 본 연구에서는 실험에 의해 검증된 식을 제시하였으며 이를 바탕으로 CFFT구조를 설계하는 알고리즘을 제안하였다. 또한 CFFT구조는 FRP관의 구속으로 인해 고강도콘크리트와 긴장재의 도입이 가능한 구조로서 이에 대한 설계도 포함하였다. 그러나 이방성재료인 FRP의 설계와 동시에 FRP관에 의한 구속효과를 고려하는 CFFT구조의 설계는 일반 실무설계자들에게는 다소 난해한 작업으로써 전산화 설계프로그램의 필요성이 대두되어 본 연구에서 CFFT구조의 설계프로그램을 개발하였다. 개발된 설계프로그램의 검증을 위해 일반 철근콘크리트기둥, CFFT기둥, 고강도콘크리트와 PS긴장재를 도입한 CFFT기둥을 설계한 결과, 매우 실용적이며 타당한 설계가 수행될 수 있음을 확인하였다.

  • PDF

A study on the Butt-welding Characteristic of PVC and PE Pipe (PVC(Polyvinyl Chloride) 하수도관의 맞대기 융착 용접에 대한 연구)

  • An, Ju-Seon;Nam, Jun-Young;Lee, Sang-Yun;Lee, Bo-Young
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.62-62
    • /
    • 2010
  • PVC(Polyvinyl Chloride)와 HDPE(High-density Polyethlene) 하수도관은 수많은 고분자 재료 중에도 높은 기계적 강도를 가지며, 광범위하게 사용되고 있다. 하지만, PVC와 HDPE 하수관을 연결하기 위해 소모 접착제나 고무링 이용한 소켓 방법 이음 방법은 낮은 수밀성과 기계적 강도로 오 폐수의 누수가 발생되고, 이것이 흙에 스며들어 지하수, 하천 및 토양을 오염시키고 있다. 따라서, 대안으로 최근에는 열판을 이용한 맞대기 융착 용접을 PE 하수도 관에 제한적으로 적용하여 시공하고 있다. 그러나, PVC 하수관은 열을 가할 시 열에 의한 민감한 거동으로 인해 맞대기 융착 용접법이 적용되지 못하고 있는 실정이다. 따라서 본 연구에서는 하수도 관 중, 국내에서 가장 많이 사용되고 있는 내 충격 PVC 하수도관과 HDPE 이중 벽관의 DSC(Diffential Scanning Calorimeter), TGA(Thermogravimetric analyzer), TMA(Thermomechanical Analysis), DMA(Dynamic Mechanical Analysis) 분석으로 온도에 따른 열적 거동을 분석하여, 적절한 융착 온도 조건을 제시하였다. 또한 접합강도 향상을 위한 이음부 설계를 제안하여, 융착 용접 특성을 평가하였다.

  • PDF

Structural Evaluations of the Bellows for a Gas-generator Lox Shut-off Valve (가스발생기 산화제 개폐밸브 주름관 구조 평가)

  • Yoo, Jae-Han;Lee, Joong-Youp;Lee, Soo-Yong;Lim, Hyeong-Tae
    • Aerospace Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.91-97
    • /
    • 2012
  • The structural analyses and experimental results for the bellows of a gas-generator liquid oxygen shut-off valve were presented. The bellows experiences axial compression and external high pressure loadings at cryogenic temperatures. The analyses were performed using EJMA (Expansion Joint Manufacturing Association) standard and the commercial FE (finite element) analysis program, Abaqus v6.9, at room and cryogenic temperatures. The spring modulus, the induced stress and the expected fatigue life of the bellows were compared respectively. The effects by the contact and the material plasticity on the FE analysis results were also analyzed. Also, FE analyses related to a burst test were presented.

Relationship between Job Stress and Burnout for Noncommissioned Officers: Focusing on Mediating Effects of Coworker Support and Emotional Stability (부사관의 직무스트레스와 소진간의 관계 : 동료 지지와 정서적 안정성의 매개효과를 중심으로)

  • Lee, Jayoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.243-249
    • /
    • 2018
  • The purpose of this study was to investigate the relationship between job stress, coworker support, emotional stability and burnout, and to examine the mediating effect of coworker support and emotional stability. A total of 212 noncommissioned officers were interviewed and correlation and mediating effect analysis were applied to the resulting data. As a result, the job stress showed a positive correlation with coworker support, emotional stability and negative correlation with burnout, and coworker support and emotional stability showed a negative correlation with burnout. In addition, coworker support and emotional stability were partially mediated by job stress and burnout. However, in order to examine the relationship between these two, the double mediation between job stress and burnout showed that the emotional stability of job stress was partially mediated directly by burnout, and that coworker support was mediated by burnout only through emotional stability. Based on these results, the implications and limitations of this study were discussed.