• Title/Summary/Keyword: 이원진

Search Result 538, Processing Time 0.029 seconds

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position (디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과)

  • Kim, Mi-Ja;Choi, Bo-Ram;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-SUk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

Diagnostic imaging analysis of the impacted mesiodens (매복 정중치의 진단영상분석)

  • Noh, Jeong-Jun;Choi, Bo-Ram;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

Sleep Habits and Insomnia-Associated Factors in Korean Adult Population: A Cross-sectional Survey of Three Rural Communities (한국 성인의 수면습관 및 불면증 관련 요인 : 3개 농촌지역주민을 대상으로 한 단시적 연구)

  • Jeong, Do-Un;Sohn, Chang-Ho;Sung, Joo-Hon;Chang, Song-Hun;Lee, Kun-Sei;Lee, Won-Jin;Shin, Hai-Rim;Lee, Bu-Ok;Cho, Soo-Hun
    • Sleep Medicine and Psychophysiology
    • /
    • v.4 no.2
    • /
    • pp.201-212
    • /
    • 1997
  • Objectives: We attempted to study sleep habits and insomnia-associated factors in Korean rural adult population. Methods : In 1,441 adult subjects of three rural communities selected by cluster sampling, we administered an epidemiologic survey using questionnaire methods from July 14, 1996 to July 28, 1996. Results : 1) Mean sleep latency and mean time to sleep again after awakening during nocturnal sleep were longer in females than in males. Females suffered more frequently from insomnia symptom, awakening during nocturnal sleep. morning headache, dysphoric mood in the morning, and the feeling of 'not refreshed' on waking-up than males. 2) The older age group (defined as those older than 65 years) was found to have earlier bed-time, longer sleep latency, more frequent nocturia, longer time to sleep again after awakening during nocturnal sleep, and more frequent insomnia symptom. 3) The presence of insomnia symptom more than once a week was significantly associated with suffering from physical illness, being divorced-separated-widowed, frequently feeling depressed, nocturia, or low education level. 4) In multiple logistic regression analysis, old age, being female, low education level, frequently feeling depressed, and nocturia were independently associated with the presence of insomnia symptom more than once a week. Conclusion : We conclude that, in a Korean rural adult population, insomnia symptom increases with age and females usually suffer more from insomnia symptom than males. In addition, low education level, feeling depressed mood frequently, and nocturia are found to be significantly associated independently with the presence of insomnia symptom more than once a week.

  • PDF

The effects of digital image processing for noise reduction on observer performance (노이즈 감소 필터 사용이 판독능에 미치는 효과)

  • Jung, Young-Chul;Choi, Bo-Ram;Huh, Kyung-Hoi;Yi, Yon-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.103-107
    • /
    • 2010
  • Purpose : This study was performed to examine the effects of image filter on observer performance by counting the number of holes at each wedge step on a radiographic image. Materials and Methods : An aluminum step wedge with 11 steps ranged in thickness from 1.5 mm to 16.5 mm in 1.5 mm increments was fabricated for this study. Each step had 10 notched holes with 1.0 mm diameter on the bottom of the step wedge which were ranged in depths from 0.1 mm to 1.0 mm in 0.1 mm increments. Digital radiographic raw images of the aluminum step wedge were acquired by using CCD intraoral sensor. The images were processed using several types of noise reduction filters and kernel sizes. Three observers counted the number of holes which could be discriminated on each step. The data were analyzed by ANOVA. Results : The number of holes at each step was decreased as the thickness of step was increased. The number of holes at each step on the raw images was significantly higher than that on the processed images. The number of holes was different according to the types and kernel sizes of the image filters. Conclusions : The types and kernel sizes of image filters on observer performance were important, therefore, they should be standardized for commercial digital imaging systems.

GPS/INS Integration and Preliminary Test of GPS/MEMS IMU for Real-time Aerial Monitoring System (실시간 공중 자료획득 시스템을 위한 GPS/MEMS IMU 센서 검증 및 GPS/INS 통합 알고리즘)

  • Lee, Won-Jin;Kwon, Jay-Hyoun;Lee, Jong-Ki;Han, Joong-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.225-234
    • /
    • 2009
  • Real-time Aerial Monitoring System (RAMS) is to perform the rapid mapping in an emergency situation so that the geoinformation such as orthophoto and/or Digital Elevation Model is constructed in near real time. In this system, the GPS/INS plays an very important role in providing the position as well as the attitude information. Therefore, in this study, the performance of an IMU sensor which is supposed to be installed on board the RAMS is evaluated. And the integration algorithm of GPS/INS are tested with simulated dataset to find out which is more appropriate in real time mapping. According to the static and kinematic results, the sensor shows the position error of 3$\sim$4m and 2$\sim$3m, respectively. Also, it was verified that the sensor performs better on the attitude when the magnetic field sensor are used in the Aerospace mode. In the comparison of EKF and UKF, the overall performances shows not much differences in straight as well as in curved trajectory. However, the calculation time in EKF was appeared about 25 times faster than that of UKF, thus EKF seems to be the better selection in RAMS.

A Study on High-Precision DEM Generation Using ERS-Envisat SAR Cross-Interferometry (ERS-Envisat SAR Cross-Interferomety를 이용한 고정밀 DEM 생성에 관한 연구)

  • Lee, Won-Jin;Jung, Hyung-Sup;Lu, Zhong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.4
    • /
    • pp.431-439
    • /
    • 2010
  • Cross-interferometic synthetic aperture radar (CInSAR) technique from ERS-2 and Envisat images is capable of generating submeter-accuracy digital elevation model (DEM). However, it is very difficult to produce high-quality CInSAR-derived DEM due to the difference in the azimuth and range pixel size between ERS-2 and Envisat images as well as the small height ambiguity of CInSAR interferogram. In this study, we have proposed an efficient method to overcome the problems, produced a high-quality DEM over northern Alaska, and compared the CInSAR-derived DEM with the national elevation dataset (NED) DEM from U.S. Geological Survey. In the proposed method, azimuth common band filtering is applied in the radar raw data processing to mitigate the mis-registation due to the difference in the azimuth and range pixel size, and differential SAR interferogram (DInSAR) is used for reducing the unwrapping error occurred by the high fringe rate of CInSAR interferogram. Using the CInSAR DEM, we have identified and corrected man-made artifacts in the NED DEM. The wave number analysis further confirms that the CInSAR DEM has valid Signal in the high frequency of more than 0.08 radians/m (about 40m) while the NED DEM does not. Our results indicate that the CInSAR DEM is superior to the NED DEM in terms of both height precision and ground resolution.

A Study on the Morphological Analysis of Sperm (정자의 형태학적 특성 분석에 관한 연구)

  • Paick, Jae-Seung;Jeon, Seong-Soo;Kim, Soo-Woong;Yi, Won-Jin;Park, Kwang-Suk
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.24 no.2
    • /
    • pp.153-165
    • /
    • 1997
  • In male reproducible health, fertility and IVF (in-vitro fertilization), semen analysis has been most important. Semen analysis can be divided into concentration, motional and morphological analysis of sperm. The existing method which was developed earlier to analyze semen concentrated on the sperm motility analysis. To provide more useful and precise solutions for clinical problems such as infertility, semen analysis must include sperm morphological analysis. But the traditional tools for semen analysis are subjective, imprecise, inaccurate, difficult to standardize, and difficult to reproduce. Therefore, with the help of development of microcomputers and image processing techniques, we developed a new sperm morphology analyzer to overcome these problems. In this study the agreement on percent normal morphology was studied between different observers and a computerized sperm morphology analyzer on a slide-by-slide basis using strict criteria. Slides from 30 different patients from the SNUH andrology laboratory were selected randomly. Microscopic fields and sperm cells were chosen randomly and percent normal morphology was recorded. The ability of sperm morphology analyzer to repeat the same reading for normal and abnormal cells was studied. The results showed that there was no significant bias between two experienced observers. The limits of agreement were 4.1%${\sim}$-3.8%. The Pearson correlation coefficient between readers was 0.79. Between the manual and sperm morphology analyzer, the same findings were reported. In this experiments the slides were stained by two different methods, PAP and Diff-Quik staining methods. The limits of agreement were 7.2%${\sim}$-5.7% and 6.0%${\sim}$-6.3%, respectively. The Pearson correlation coefficients ware 0.76 and 0.91, respectively. The limits of agreement was tighter below 20% normal forms. In the experiments of repeatability, 52 cells stained by PAP and Diff-Quik staining methods were analyzed three times in succession. Estimating pairwise agreement, the kappa statistic for the pairs were 0.76, 0.81, 0.86, and 0.75, 0.88, 0.88 respectively. In this study it was shown that there was good agreement between manual and computerized assessment of normal and abnormal cells. The repeatability and agreement per slide of computerized sperm morphology analyzer was excellent. The computer's ability to classify normal morphology per slide is promising. Based on results obtained, this system can be of clinical value both in andrology laboratories and IVF units.

  • PDF

GEMS BrO Retrieval Sensitivity Test Using a Radiative Transfer Model (복사전달모델을 이용한 GEMS 일산화브로민 산출 민감도 시험)

  • Chong, Heesung;Kim, Jhoon;Jeong, Ukkyo;Park, Sang Seo;Hong, Jaemin;Ahn, Dha Hyun;Cha, Hyeji;Lee, Won-Jin;Lee, Hae-jung
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1491-1506
    • /
    • 2021
  • To estimate errors in GEMS retrievals for bromine monoxide (BrO) total vertical column densities(VCDs), we perform a sensitivity test using synthetic spectra generated by a radiative transfer model. Hourly synthetic data are produced for 00-07 UTC on the first day of every month in Jul 2013- Jun 2014. Solution errors estimated by the optimal estimation method tend to decrease with increasing air mass factors (AMFs) but increase when AMFs are larger than 5. Interference errors induced by formaldehyde (HCHO) absorption appear to be larger with smaller BrO AMFs. Total BrO retrieval errors estimated by combining solution and interference errors show an average of 26.74±30.18% for all data samples and 60.39±133.78% for those with solar zenith angles higher than 80°. Due to interfering spectral features and measurement errors not considered in thisstudy, errorsin BrO retrievals from actual GEMS measurements may have different magnitudes from our estimates. However, the variability of errors assessed in this study is still expected to appear in the actual BrO retrievals.

Detection for Region of Volcanic Ash Fall Deposits Using NIR Channels of the GOCI (GOCI 근적외선 채널을 활용한 화산재 퇴적지역 탐지)

  • Sun, Jongsun;Lee, Won-Jin;Park, Sun-Cheon;Lee, Duk Kee
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.6_4
    • /
    • pp.1519-1529
    • /
    • 2018
  • The volcanic ash can spread out over hundreds of kilometers in case of large volcanic eruption. The deposition of volcanic ash may induce damages in urban area and transportation facilities. In order to respond volcanic hazard, it is necessary to estimate efficiently the diffusion area of volcanic ash. The purpose of this study is to compare in-situ volcanic deposition and satellite images of the volcanic eruption case. In this study, we used Near-Infrared (NIR) channels 7 and 8 of Geostationary Ocean Color Imager (GOCI) images for Mt. Aso eruption in 16:40 (UTC) on October 7, 2016. To estimate deposit area clearly, we applied Principal Component Analysis (PCA) and a series of morphology filtering (Eroded, Opening, Dilation, and Closing), respectively. In addition, we compared the field data from the Japan Meteorological Agency (JMA) report about Aso volcano eruption in 2016. From the results, we could extract volcanic ash deposition area of about $380km^2$. In the traditional method, ash deposition area was estimated by human activity such as direct measurement and hearsay evidence, which are inefficient and time consuming effort. Our results inferred that satellite imagery is one of the powerful tools for surface change mapping in case of large volcanic eruption.