• Title/Summary/Keyword: 이온확산

Search Result 651, Processing Time 0.026 seconds

Diffusion Characteristics for Chloride Ion of Concrete Subjected to Sulfate Attack (황산염 침투를 받은 콘크리트의 염소이온 확산특성)

  • Park, Jae-Im;Bae, Su-Ho;Yu, Jae-Won;Lee, Kwang-Myong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.213-214
    • /
    • 2010
  • An objective of this experimental research is to investigate the diffusion characteristics for chloride ion of concrete subjected to sulfate attack. For this purpose, concretes with three types of cement such as ordinary portland cement(OPC), binary blended cement(BBC), and ternary blended cement(TBC) containing mineral admixtures were made for water-binder ratios of 32% and 43%. The concrete specimens were immersed in sulfate solution for 365 days, and then the resistance against chloride ion penetration of them were estimated by using NT BUILD 492. It was observed from the test results that the resistance to chloride ion penetration of concrete subjected to sulfate attack was greatly decreased than that of standard curing concrete under the same age.

  • PDF

Electrochromic 막의 특성과 물질이동 방지막의 효과에 대한 연구

  • 황하룡;백지흠;허증수;이대식;이덕동;임정옥;장동식
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.66-66
    • /
    • 2000
  • Electrochromism이란 기전력 방향에 의한 가역적으로 색이 변하는 현상을 말하며, 열린 회로 기억성을 가지며 소비전력이 적고, 우수한 착색 효율을 갖는 등 여러 가지 유용성 때문에 디스플레이 및 전기적 착색 유리창에의 기술적 적용 가능성을 보이고 있다. 본 연구에서는 가장 우수한 일렉트로크로믹 특성을 내는 것으로 알려진 WO3 박막과 대향 전극으로 V2O5 박막을 사용하였다. 이들 박막은 알칼리 이온 주입물질이며, coloration.bleaching상태에서 광학 밀도가 크고, 내구성이 좋으며, 작은 비용으로 재료를 사용할 수 있다. 그리고 더 우수한 장점으로 부각되는 대면적의 코팅의 매력적인 기술인 졸겔법으로 제조 가능한 특성을 가지고 있다. 졸겔법 및 진공증착법으로 박막을 제조하고, 박막산화 및 수명저하 등의 위험이 적은 리튬이온을 이용하여 소자를 제작한 후 일렉트로크로믹 특성을 조사하고, 우수한 소자의 제조조건을 얻고자 하였다. 측정결과 졸겔법으로 제조된 WO3 박막과 V2O5 박막을 수증기 분위기에서 50$0^{\circ}C$로 1시간 열처리한 경우 가장 우수한 투과 변화율을 나타내었다. 정상전압인 2 volt보다 높은 3 volt로 cyclic voltamogram을 측정하는 과정에서 정.역방향 동작을 거듭할수록 peak이 크게 감소하는 현상을 발견하였으며, 양이온의 흐름에 의해 물질의 이동이 발생할 것이라는 판단아래 Auger depth profile을 측정한 결과 WO3막의 텅스텐과 ITO막의 인듐이 상호 확산하는 것을 관찰할 수 있었다. 이를 방지하기 위해 수백 의 텅스텐 박막을 WO3 막 위에 증착한 후 cyclic voltamogram과 Auger depth profile을 측정한 결과, cyclic voltamogram의 peak의 감소량이 1/10이하로 감호하였으며, 리튬이온의 흐름에 의한 인듐과 텅스텐의 이동을 효과적으로 방지할 수 있었다. 따라서 텅스텐 확산방지막의 삽입이 소자의 수명을 향상시킬 수 있는 효과적인 방법이라고 사료된다.

  • PDF

A study of electrical characteristic of MOSFET device (고에너지 이온주입에 따른 격자 결함 발생 및 거동에 관한 열처리 최적화방안에 관한 연구)

  • Song, Young-Doo;Kwack, Kae-Dal
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1830-1832
    • /
    • 1999
  • 고에너지 이온주입(1)에 기인한 격자 손상 발생 및 열처리에 따라 이들의 회복이 어느정도 가능한지에 대하여 측정 및 분석방법을 통하여 조사하였다. 그리고 본 실험에서는 이온주입시 형성되는 빈자리 결함(Vacancy defect)과 격자간 결함(interstitial defect)의 재결할(recombination)을 이용 점결합(point defect)를 감소 시킬 수 있는 effective RTA조건을 설정하여 well 특성을 개선하고자 하였다. 8inch p-type Si(100)기판에 pad oxide 100A을 형성한 후 NMOS 형성하기 위해 vtn${\sim}$p-well과 PMOS 형성을 위해 vtp$\sim$n-well을 이온주입 하였다. Mev damage anneal은 RTA(2)(Rapid Thermal Anneal)로 $1000\sim1150C$ 온도에서 $15\sim60$초간 spilt 하여 실험후 suprem-4 simulation data를 이용하여 실제 SIMS측정 분석결과를 비교하였으며 이온주입에 의해 발생된 격자손상이 열처리후 damage 정도를 알아보기 위해 T.W(Therma-Wave)을 이용하였으며 열처리후 면저항값은 4-point probe를 사용하였다. 이온주입후 열처리 전,후에 따른 불순물 분포를 SIMS(Secondary ion Mass Spectrometry)를 이용하여 살펴보았다. SIMS 결과로는 열처리 온도 및 시간의 증가에 따라서 dopant확산 및 활성화는 큰차이는 보이지 않고 오히려 감소하는 경향을 볼 수 있으며 또한 접합깊이와 농도가 약간 낮아지는 것을 볼 수 있었다. 결점(defect)을 감소시키기 위해서 diffusivity가 빠른 임계온도영역($1150^{\circ}C$-60sec)에서 RTA를 실시하여 dopant확산을 억제하고 점결점(point defect)의 재결합(recombination)을 이용하여 전위 (dislocation)밀도를 감소시켜 이온주입 Damage 및 면저항을 감소 시켰다. 이와 같은 특성을 process simulation(3)(silvaco)을 통하여 비교검토 하였다.

  • PDF

Ion Conductivity of Membrane in Proton Exchange Membrane Fuel Cell (고분자전해질 연료전지에서 고분자 막의 이온 전도도)

  • Hwang, Byungchan;Chung, Hoi-Bum;Lee, Moo-Seok;Lee, Dong-Hoon;Park, Kwonpil
    • Korean Chemical Engineering Research
    • /
    • v.54 no.5
    • /
    • pp.593-597
    • /
    • 2016
  • The effects of relative humidity, current density and temperature on the ionic conductivity were studied in PEMFC (Proton Exchange Membrane Fuel Cell). Water contents and water flux in the electrolyte membrane largely affected ion conductivity. The water flux was modelled and simulated by only electro-osmotic drag and back-diffusion of water. Ion conductivities were measured at membrane state out of cell and measured at MEA (Membrane and Electrode Assembly) state in condition of operation. The water contents in membrane increase as relative humidity increased in PEMFC, as a results of which ion conductivity increased. Current enhanced electro-osmotic drag and back diffusion and then water contents linearly increased. Enhancement of current density results in ion conductivity. Ion conductivity of about 40% increased as the temperature increased from $50^{\circ}C$ to $80^{\circ}C$.

Time-dependent characteristics of chloride diffusion coefficient of concrete (콘크리트 염소이온 확산계수의 시간 의존적 특성)

  • Choi, Sung;Lee, Kwang-Myong;Shin, Kyung-Joon;Bae, Su-Ho
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.545-548
    • /
    • 2008
  • As the corrosion of reinforcing bar in concrete structures exposed to chloride attack is one of main factors to determine the remaining service life, marine concrete structures have to be designed to protect the chloride penetration. Among the durability design methods such as deterministic method and probabilistic method, design method based on the probabilistic theory has been widely studied. However, the most essential material, data of the material properties related to chloride diffusion, are still insufficient. In this paper, the probabilistic distribution of chloride diffusion coefficients and aging coefficients are derived by the experiment and analysis for the chloride coefficients of concrete containing pozzolans, which are generally used in marine structures.

  • PDF

Analysis of Chloride ion Penetration for In-place Concrete Structure (현장 콘크리트 구조물에 대한 염소이온 침투 해석)

  • 한상훈;박우선
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.307-314
    • /
    • 2003
  • 해양콘크리트 구조물의 내구성에 가장 큰 영향은 미치는 요인 중의 하나가 염소 이온의 침투에 의한 철근부식이다. 염소이온이 콘크리트 구조물 내부로 확산되어 철근이 부식하게 되면 철근의 부피팽창으로 콘크리트 덮개에 균열이 발생하고 철근의 단면적도 줄어들게 된다. 따라서, 구조물은 사용연한을 채우지 못 하고 붕괴되거나 사용성에 큰 문제가 발생하게 된다. (중략)

  • PDF

Comparisons of Grain Size Analysis Results by Different Pretreatments Procedures in Loess-paleosol Sediments (뢰스-고토양 퇴적물의 전처리 과정에 따른 입도분석 결과 비교)

  • Yoon, Soon-Ock;Park, Chung-Sun;Hwang, Sang-Ill
    • Journal of the Korean Geographical Society
    • /
    • v.45 no.5
    • /
    • pp.553-572
    • /
    • 2010
  • Grain size analysis of sediments and soils has been regarded as a one of the most important analytical methods in Earth Sciences. The results of grain size analysis by 10 different pretreatment procedures in loess-paleosol sediments are compared in the study. In spite of the most powerful effectiveness of dispersant(sodium hexametaphosphate) on the dispersions of sediments, the effects show large differences by its treatment orders with HCl. It may result from that $Na^+$ ions in the dispersant may not be able to effectively substitute $Ca^{2+}$ ions in the sediments due to the electrostatic forces between $Na^+$ and $Cl^-$ ions in the dispersant and HCl, respectively. Although $H_2O_2$ and HCl are more effective in dispersion than hot water, they do not affect greatly the dispersions. Therefore, the reliable results of grain size analysis can be obtained by selecting the adequate pretreatment procedures most suitable for the purposes of researches and characteristics of sediments.

An Experimental Study on the Resistance of Nylon Fiber Reinforced Concrete to Chloride Ion Penetration (나일론섬유보강 콘크리트의 염소이온 침투 저항성에 대한 실험적 연구)

  • Jeon, Joong-Kyu;Moon, Jae-Heum;You, Jin-O
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.557-560
    • /
    • 2008
  • Fiber reinforcement has been being widely used in concrete to enhance the mechanical properties and to reduce the micro-cracking caused by plastic and drying shrinkage. While researches has been focused on the benefits of fiber reinforcement, the properties of fiber reinforced concrete are strongly dependent on the type, shape and the amount of fibers in concrete. In this study, the resistance of nylon fiber reinforced concrete against the chloride ion penetration was experimentally observed by NT Build 492. The test results showed that the addition of nylon fiber has little effect on the change of the resistivity of concrete to the chloride ion penetration.

  • PDF