• Title/Summary/Keyword: 이온현미경

Search Result 381, Processing Time 0.027 seconds

Fault Analysis of Semiconductor Device (반도체 장치의 결함해석)

  • Park, S.J.;Choi, S.B.;Oh, C.S.
    • Journal of Energy Engineering
    • /
    • v.25 no.1
    • /
    • pp.192-197
    • /
    • 2016
  • We have surveyed on technical method of fault analysis of semiconductor device. Fault analysis of semiconductor should first be found the places of fault spots. For this process they are generally used the testers; EB(emission beam tester), EM(emission microscope), OBIRCH(optical beam induced resistance change method) and LVP(laser voltage probing) etc. Therefore we have described about physical interpretation and technical method in using scanning electron microscope, transmission electron microscope, focused ion beam tester and Nano prober.

Morphological Changes Associated with the Antibacterial Action of Silver Ions against Bovine Mastitis Pathogens (은 이온의 항균효과에 대한 소 유방염 원인균의 형태학적 변화)

  • Kang, Seog-Jin;Seol, Jae-Won;Hur, Tai-Young;Jung, Young-Hun;Choe, Chang-Yong;Park, Sang-Youel
    • Journal of Veterinary Clinics
    • /
    • v.28 no.6
    • /
    • pp.576-580
    • /
    • 2011
  • Silver has potent antibacterial activity against a variety of bacteria while maintaining low toxicity in mammalian cells. This study was conducted to investigate the possible mechanism underlying the bactericidal effects of silver ions against bovine mastitis pathogens using electron microscopy. We used two different bacterial strains, Escherichia coli and Staphylococcus aureus, which are primarily responsible for the majority of bovine mastitis cases. Interaction between the bacteria and silver ions (50 ${\mu}g/mL$, 2 hours) were studied using energy-filtering transmission electron microscopy (EFTEM). EFTEM images showed that E. coli and S. aureus cells treated with the silver ions had distorted plasma membranes, silver ions attached to the outer membranes, scattered electron-light material, and leakage of cell contents from disrupted cell membranes.

Crab shell을 이용한 수중의 납 이온 제거에 관한 연구

  • 안희경;박병윤;김동석
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2000.05a
    • /
    • pp.189-194
    • /
    • 2000
  • 1) Crab shell의 납 흡착 실험결과 Langmuir 흡착 등온 모델에 잘 적용되었으며 $q_{max}$은 335.4 mg/g이었다. 2) 12시간 흡착 반응시킨 후 초기 농도에 대한 납 이온 제거효율을 고찰한 결과, 초기 납 이온 농도가 207.2 mg/l 이하에서는 97% 이상의 납 이온 제거 효율을 나타내었는데, 414.4 mg/l 이상에서는 제거효율이 60% 이하로 감소하였다. 3) 납 이온 흡착 전과 흡착 후의 crab shell을 전자현미경으로 분석한 결과 crab shell의 표면과 내부의 변화를 관찰할 수 있었다.

  • PDF

Damage of Minerals in the Preparation of Thin Slice Using Focused Ion Beam for Transmission Electron Microscopy (투과전자현미경분석용 박편 제작 시 집속이온빔에 의한 광물 손상)

  • Jeong, Gi Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.293-297
    • /
    • 2015
  • Focused ion beam (FIB) technique is widely used in the precise preparation of thin slices for the transmission electron microscopic (TEM) observation of target area of the minerals and geological materials. However, structural damages and artifacts by the Ga ion beam as well as electron beam damage are major difficulties in the TEM analyses. TEM analyses of the mineral samples showed the amorphization of quartz and feldspar, curtain effect, and Ga contamination, particularly near the grain edges and relatively thin regions. Although the ion beam damage could be much reduced by the improved procedures including the adjustment of the acceleration voltage and current, the ion beam damage and contamination are likely inevitable, thus requiring careful interpretation of the micro-structural and micro-chemical features observed by TEM analyses.

Development of Ambient Ionization Mass Spectrometry Imaging for Live Cells and Tissues

  • Kim, Jae-Yeong;Seo, Eun-Seok;Lee, Seon-Yeong;Jeong, Gang-Won;Mun, Dae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.229.1-229.1
    • /
    • 2015
  • 생체 시료인 세포나 조직을 분석을 위해 임의로 파괴하거나 훼손하지 않은 본래의 상태에서 세포에 존재하는 다양한 생체분자 물질의 질량과 조성을 분석하고 영상화할 수 있는 대기압 표면 질량분석 이미징 기술을 개발했다. 생체 시료의 표면을 질량 분석을 하기 위해서는 대기압 분위기에서 시료에 열적 손상이 없는 조건으로 시편의 이온화 및 탈착 과정이 이루어지게 하기 위해 저온 대기압 탈착/이온화원으로 저온대기압 플라즈마 젯과 펨토초 적외선 레이저를 결합하여 대기압 이온화원을 제작하였다. 기존에 잘 알려진 저온 대기압 플라즈마 젯 소자는 유리관에 방전기체를 흘려주고 전극에 고전압을 인가하는 방식으로 제작했으며, 또 다른 대기압 이온화원으로서 근적외선 대역의 고출력 펨토초 레이저 빔을 현미경용 대물렌즈로 집속하여 생체시료에 조사시켰다. 수백 나노미터에서 수 마이크로미터 수준으로 빔을 집속할 수 있는 펨토초 레이저는 금나노로드의 도움으로 생체 시료를 매우 작은 수준으로 탈착하는 데 주로 사용하며, 수십 마이크로미터에서 수 밀리미터 정도의 크기를 가지는 저온 대기압 플라즈마 젯은 탈착된 물질을 이온화시키는데 사용하여, 이 두 가지 이온화원을 결합하여 이온화원으로 사용한다. 시료에서 발생한 이온을 질량분석기 입구까지 잘 끌고 갈 수 있도록 이온 전달관을 설계하고 보조펌프를 장착 사용한다. 이렇게 자체 개발한 대기압 이온화원을 상용 질량분석기기와 결합하여 대기압 분위기에서 시료의 표면을 질량분석할 수 있는 시스템과 측정 기술을 개발했다. 현미경 스테이지에 정밀 2-D 자동 스캐닝 스테이지를 장착하여 질량분석 정보에 공간 정보를 더할 수 있는 질량분석 이미징 기술 방법을 개발하여 생체 시편의 질량분석 이미징을 얻었다. 수분을 포함하는 생채시료로부터 단백질, 지질, 대사물질을 직접 분리하여 분석하는 이 새로운 질량분석법은 기존의 분석법에 비해 훨씬 더 많은 생체분자 정보를 얻을 수 있으며 공간정보를 더해 영상화할 수 있는 큰 장점이 있다. 대기압 표면 질량분석 기술은 생체시료를 파괴해서 용액화할 필요도 없으며, 진공 챔버에 넣기 위해 필요한 복잡한 전처리 과정 단계를 간략화 할 수 있으며 최종적으로는 살아있는 세포나 생체 조직도 정량 분석이 가능하여 생명과학 및 의료진단 분야에서 응용할 수 있는 분야는 무궁무진할 것이다.

  • PDF

Detection of Intracellular Free Metal Ions with Molecular Two-Photon Sensors (이광자 분자센서를 이용한 생체 내 금속이온 검출)

  • Kim, Hwan-Myung
    • Clean Technology
    • /
    • v.17 no.3
    • /
    • pp.231-237
    • /
    • 2011
  • Two-photon microscopy (TPM) is attracting much attention in biological imaging due to the capability of imaging deep inside the living tissues for a long period of time. For maximum utilization of TPM, it is essential to develop efficient twophoton sensors. Regarding this, many research groups are developing two-photon sensors for specific applications. In this review, we summarize recent results on selected examples of two-photon sensors for intracellular free metal ions in the live cells and tissues to provide a guideline for various imaging applications.