• Title/Summary/Keyword: 의료영상저장전송 시스템

Search Result 74, Processing Time 0.041 seconds

The Design of Mobile Medical Image Communication System based on CDMA 1X-EVDO for Emergency Care (CDMA2000 1X-EVDO망을 이용한 이동형 응급 의료영상 전송시스템의 설계)

  • Kang, Won-Suk;Yong, Kun-Ho;Jang, Bong-Mun;Namkoong, Wook;Jung, Hai-Jo;Yoo, Sun-Kook;Kim, Hee-Joung
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.53-55
    • /
    • 2004
  • In emergency cases, such as the severe trauma involving the fracture of skull, spine, or cervical bone, from auto accident or a fall, and/or pneumothorax which can not be diagnosed exactly by the eye examination, it is necessary the radiological examination during transferring to the hospital for emergency care. The aim of this study was to design and evaluate the prototype of mobile medical image communication system based on CDMA 1X EVDO. The system consists of a laptop computer used as a transmit DICOM client, linked with cellular phone which support to the CDMA 1X EVDO communication service, and a receiving DICOM server installed in the hospital. The DR images were stored with DICOM format in the storage of transmit client. Those images were compressed into JPEG2000 format and transmitted from transmit client to the receiving server. All of those images were progressively transmitted to the receiving server and displayed on the server monitor. To evaluate the image quality, PSNR of compressed image was measured. Also, several field tests had been performed using commercial CDMA2000 1X-EVDO reverse link with the TCP/IP data segments. The test had been taken under several velocity of vehicle in seoul areas.

  • PDF

U-Healthcare & Medical Information System of Status and Operative Challenges for Integrated Medical Information System (U-Healthcare 및 의료정보시스템의 현황과 통합의료정보시스템을 위한 운영과제)

  • Kim, Bo-Soo
    • Journal of Digital Convergence
    • /
    • v.9 no.5
    • /
    • pp.65-75
    • /
    • 2011
  • For the latest information and communication technology convergence with related technology to integrate all the systems has been developed in the form. In this era as well as the flow of the healthcare industry in recent years many studies on the development and application has been actively. Health IT in healthcare information systems that integrate information systems that have evolved rapidly in the direction to go, and in the future it is expected to do better acceleration. In this paper, state-led ubiquitous environment for building the hospital application system and IT application services are practical and Free in the integrated health information for the patient care service strengthening to integrated medical information system proposal and design do's and At the same time the establishment of integrated health information systems plans and operational challenges presented.

A study of Image Restoration using User Defined Mean.Wiener Filters in u-Health Care (u-헬스 케어에서 사용자 정의 평균.위너필터를 이용한 영상복원에 관한 연구)

  • Lee, Hyun-Chang;Shin, Hyun-Cheul
    • Journal of the Korea Society of Computer and Information
    • /
    • v.13 no.2
    • /
    • pp.121-125
    • /
    • 2008
  • According to the development of software and hardware about multimedia technologies, images are used to store information extracted from data. Noises by various causes, however, are added in the process of forming images, recording and transmitting in ubiquitous environments. In image restoration viewpoints to remove them. appropriate filtering methodologies, wiener of mean etc, are utilized. Various ways for image restoration are studied as well. Therefore, in this paper, we Propose user defined image restoration that applies the most appropriate parameters for image restoration and show the implementation result of the system using various parameters including mean filter and wiener filter to advance quality of degraded source image affected by noise in ubiquitous environment and medical fields.

  • PDF

Study on Radiation Dose in the Medical Image Data Display Method - Focused on the DICOM Standard (의료영상 데이터에서의 피폭선량 표시 방법에 관한 고찰: DICOM 표준을 중심으로)

  • Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.483-489
    • /
    • 2015
  • DICOM (Digital Imaging and Communications in Medicine) standards are generally introduced as de facto and de jure standards in modern medical imaging devices to store and to transmit medical image information. DICOM Dose Structured Report (DICOM dose SR) is implemented to report radiation exposure information in image acquiring process. and DIOCM Modality Performed Procedure Step (DICOM MPPS) is also partly used to report this exposure with the information in its DICOM tag. This article is focused on three type of radiation exposure information of DICOM standards, 1) DICOM dose SR, 2) DICOM MPPS and 3) Radiation Exposure Monitoring(REM) profile by Integrating the Healthcare Enterprise(IHE), to study on radiation exposure reporting. Healthcare facility and its staff of medical imaging related to radiation exposure should have a deep understanding of radiation exposure, and it required a standards to enhance the quality control of medical imaging and the safety of patients and staffs. Staff member have to pay attention on radiation exposures and controling processes from the purchasing stage of X-ray devices.

Region-Growing Segmentation Algorithm for Rossless Image Compression to High-Resolution Medical Image (영역 성장 분할 기법을 이용한 무손실 영상 압축)

  • 박정선;김길중;전계록
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.1
    • /
    • pp.33-40
    • /
    • 2002
  • In this paper, we proposed a lossless compression algorithm of medical images which is essential technique in picture archive and communication system. Mammographic image and magnetic resonance image in among medical images used in this study, proposed a region growing segmentation algorithm for compression of these images. A proposed algorithm was partition by three sub region which error image, discontinuity index map, high order bit data from original image. And generated discontinuity index image data and error image which apply to a region growing algorithm are compressed using JBIG(Joint Bi-level Image experts Group) algorithm that is international hi-level image compression standard and proper image compression technique of gray code digital Images. The proposed lossless compression method resulted in, on the average, lossless compression to about 73.14% with a database of high-resolution digital mammography images. In comparison with direct coding by JBIG, JPEG, and Lempel-Ziv coding methods, the proposed method performed better by 3.7%, 7.9% and 23.6% on the database used.

  • PDF

The Trends and Prospects of Health Information Standards : Standardization Analysis and Suggestions (의료정보 표준에 관한 연구 : 표준화 분석 및 전망)

  • Kim, Chang-Soo
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.1-10
    • /
    • 2008
  • Ubiquitous health care system, which is one of the developing solution technologies of IT, BT and NT, could give us new medical environments in future. Implementing health information systems can be complex, expensive and frustrating. Healthcare professionals seeking to acquire or upgrade systems do not have a convenient, reliable way of specifying a level of adherence to communication standards sufficient to achieve truly efficient interoperability. Great progress has been made in establishing such standards-DICOM, IHE and HL7, notably, are now highly advanced. IHE has defined a common framework to deliver the basic interoperability needed for local and regional health information networks. It has developed a foundational set of standards-based integration profiles for information exchange with three interrelated efforts. HL7 is one of several ANSI-accredited Standards Developing Organizations operating in the healthcare arena. Most SDOs produce standards (protocols) for a particular healthcare domain such as pharmacy, medical devices, imaging or insurance transactions. HL7's domain is clinical and administrative data. HL7 is an international community of healthcare subject matter experts and information scientists collaborating to create standards for the exchange, management and integration of electronic healthcare information. The ASTM specification for Continuity of Care Record was developed by subcommittee E31.28 on electronic health records, which includes clinicians, provider institutions, administrators, patient advocates, vendors, and health industry. In this paper, there are suggestions that provide a test bed, demonstration and specification of how standards such a IHE, HL7, ASTM can be used to provide an integrated environment.

  • PDF

Design and Implementation of Web-Based MINI-PACS using the DICOM (DICOM을 이용한 웹 기반 MINI-PACS 설계 및 구현)

  • 지연상;이성주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1095-1104
    • /
    • 2000
  • In recent years, medical procedures have become more complex, while financial pressures for shortened hospital stays and increased efficiency in patient care have increased. As a result, several shortcomings of present film-based systems for managing medical images have become apparent. Maintaining film space is labor intensive and consumes valuable space. Because only single copies of radiological examinations exist, they are prone to being lost or misplaced, thereby consuming additional valuable time and expense. In this paper, mini-PACS for image archiving, transmission, and viewing offers a solution to these problems. Proposed mini-PACS consists of mainly four parts such as web module, client-server module, internal module, acquisition module. In addition, mini-PACS system includes DICOM converter that non-DICOM file format converts standard file format. In client-server module case, proposed system is combined both SCU (service class user: client) part and SCP(service class provider: sewer)part therefore this system provides the high resolution image processing techniques based on windows platform. Because general PACS system is too expensive for medium and small hospitals to install and operate the full-PACS. Also, we constructed web module for database connection through the WWW.

  • PDF

Design and Implementation of Mobile Medical Information System Based Radio Frequency IDentification (RFID 기반의 모바일 의료정보시스템의 설계 및 구현)

  • Kim, Chang-Soo;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.317-325
    • /
    • 2005
  • The recent medical treatment guidelines and the development of information technology make hospitals reduce the expense in surrounding environment and it requires improving the quality of medical treatment of the hospital. That is, with the new guidelines and technology, hospital business escapes simple fee calculation and insurance claim center. Moreover, MIS(Medical Information System), PACS(Picture Archiving and Communications System), OCS(Order Communicating System), EMR(Electronic Medical Record), DSS(Decision Support System) are also developing. Medical Information System is evolved toward integration of medical IT and situation si changing with increasing high speed in the ICT convergence. These changes and development of ubiquitous environment require fundamental change of medical information system. Mobile medical information system refers to construct wireless system of hospital which has constructed in existing environment. Through RFID development in existing system, anyone can log on easily to Internet whenever and wherever. RFID is one of the technologies for Automatic Identification and Data Capture(AIDC). It is the core technology to implement Automatic processing system. This paper provides a comprehensive basic review of RFID model in Korea and suggests the evolution direction for further advanced RFID application services. In addition, designed and implemented DB server's agent program and Client program of Mobile application that recognized RFID tag and patient data in the ubiquitous environments. This system implemented medical information system that performed patient data based EMR, HIS, PACS DB environments, and so reduced delay time of requisition, medical treatment, lab.

  • PDF

Implementation of Education System on PACS Administorusing e-Learning (e-Learning을 이용한 PACS 영상관리사 교육시스템 구현)

  • Park, Byung-Rae;Kang, Se-Sik;Ko, Seong-Jin;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.61-66
    • /
    • 2004
  • In order to improve an efficiency of education and acquisition of PACS administor in Radiological technologist, we implement an e-Learing databank system providing more efficiently provide medical questions set for the integrated education and PACS administor without the limitation of time and space based on XML that is the standard of exchange and transmission of Web documents via Internet. The proposed system is composed of administration module and user module. The former supports some functions: a creation, classification, and management of Radiological question set. Our system can elevate ability of learning and interchange of information among Radiological technologist making preparation of PACS administor for Radiological technologist examination. Finally, our system can maximize an effectiveness of education by evaluating and training users individually with various level according to the user's ability of learning and realization.

  • PDF

Design and Development of Middleware for Clinical Trial System based on Brain MR Image (뇌 MR 영상기반 임상연구 시스템을 위한 미들웨어 설계 및 개발)

  • Jeon, Woong-Gi;Park, Kyoung-Jong;Lee, Young-Seung;Choi, Hyun-Ju;Jeong, Sang-Wook;Kim, Dong-Eog;Choi, Heung-Kook
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.6
    • /
    • pp.805-813
    • /
    • 2012
  • In this paper, we have designed and developed a middleware for an effectively approaching database to the existed brain disease clinical research system. The brain disease clinical research system was consisted of two parts i.e., a register and an analyzer. Since the register collects the registration data the analyzer yields a statistical data which based on the diverse variables. The middleware has designed to database management and a large data query processing of clients. By separating the function of each feature as a module, the module which was weakened connectivity between functionalities has been implemented the re-use module. And image data module used a new compression method from image to text for an effective management and storage in database. We tested the middleware system using 700 actual clinical medical data. As a result, the total data transmission time was improved maximum 115 times faster than the existing one. Through the improved module structures, it is possible to provide a robust and reliable system operation and enhanced security functionality. In the future, these middleware importances should be increased to the large medical database constructions.