The Design of Mobile Medical Image Communication System based on CDMA 1X-EVDO for Emergency Care

CDMA2000 1X-EVDO망을 이용한 이동형 응급 의료영상 전송시스템의 설계

  • Kang, Won-Suk (Department of Medical Science, Yonsei University College of Medicine, Research Institute of Radiological Science, Yonsei University College of Medicine, Development Center of Emergency Medical Informatics) ;
  • Yong, Kun-Ho (Department of Medical Science, Yonsei University College of Medicine) ;
  • Jang, Bong-Mun (Department of Medical Science, Yonsei University College of Medicine, Development Center of Emergency Medical Informatics) ;
  • Namkoong, Wook (Department of Medical Science, Yonsei University College of Medicine, Research Institute of Radiological Science, Yonsei University College of Medicine, Development Center of Emergency Medical Informatics) ;
  • Jung, Hai-Jo (Department of Medical Science, Yonsei University College of Medicine, Research Institute of Radiological Science, Yonsei University College of Medicine, Development Center of Emergency Medical Informatics, Department of Biomedical Engineering, Yonsei University College of Medicine) ;
  • Yoo, Sun-Kook (Development Center of Emergency Medical Informatics, Department of Biomedical Engineering, Yonsei University College of Medicine) ;
  • Kim, Hee-Joung (Department of Medical Science, Yonsei University College of Medicine, Research Institute of Radiological Science, Yonsei University College of Medicine, Development Center of Emergency Medical Informatics, Department of Radiology, Yonsei University College of Medicine)
  • 강원석 (연세대학교 대학원 의과학과, 연세대학교 의과대학 방사선의과학연구소, 이동형 응급의료정보시스템 개발센터) ;
  • 양건호 (연세대학교 대학원 의과학과) ;
  • 장봉문 (연세대학교 대학원 의과학과, 이동형 응급의료정보시스템 개발센터) ;
  • 남궁욱 (연세대학교 대학원 의과학과, 연세대학교 의과대학 방사선의과학연구소, 이동형 응급의료정보시스템 개발센터) ;
  • 정해조 (연세대학교 대학원 의과학과, 연세대학교 의과대학 방사선의과학연구소, 이동형 응급의료정보시스템 개발센터, 연세대학교 의과대학 의학공학교실) ;
  • 유선국 (이동형 응급의료정보시스템 개발센터, 연세대학교 의과대학 의학공학교실) ;
  • 김희종 (연세대학교 대학원 의과학과, 연세대학교 의과대학 방사선의과학연구소, 이동형 응급의료정보시스템 개발센터,연세대학교 의과대학 진단방사선과학교실)
  • Published : 2004.11.26

Abstract

In emergency cases, such as the severe trauma involving the fracture of skull, spine, or cervical bone, from auto accident or a fall, and/or pneumothorax which can not be diagnosed exactly by the eye examination, it is necessary the radiological examination during transferring to the hospital for emergency care. The aim of this study was to design and evaluate the prototype of mobile medical image communication system based on CDMA 1X EVDO. The system consists of a laptop computer used as a transmit DICOM client, linked with cellular phone which support to the CDMA 1X EVDO communication service, and a receiving DICOM server installed in the hospital. The DR images were stored with DICOM format in the storage of transmit client. Those images were compressed into JPEG2000 format and transmitted from transmit client to the receiving server. All of those images were progressively transmitted to the receiving server and displayed on the server monitor. To evaluate the image quality, PSNR of compressed image was measured. Also, several field tests had been performed using commercial CDMA2000 1X-EVDO reverse link with the TCP/IP data segments. The test had been taken under several velocity of vehicle in seoul areas.

본 연구에서는 병원에서 멀리 떨어진 교통사고, 낙상에 의한 두개골이나 경추, 척추등의 골절을 동반한 심각한 외상이 있거나 기흉등의 육안으로 진단하기 힘든 응급환자에 있어서는, 구급차를 이용하여 후송중이라 하더라도 방사선검사를 하여 전문의로부터 적절한 진단을 받고 응급조치를 할 필요가 있다. 본 연구의 목적은 응급상황에 사용할 수 있도록 CDMA 1X EVDO 방식의 통신망을 기반으로 하는 이동형 의료영상 전송장치의 프로토타입을 구현하고 성능을 평가하는 것이다. 설계된 시스템은 영상을 전송하기 위한 DICOM 영상전송 클라이언트로 노트북 컴퓨터에 CDMA 1X EVDO 방식을 지원하는 셀룰러폰을 연결하였으며, 병원에는 영상을 받기 위한 DICOM 영상수신 서버를 설치하였다. DR영상을 영상전송 클라이언트의 저장소에 저장한 후, JPEG2000형식으로 압축하여 수신서버로 전송하였다. 모든 영상은 progressive하게 전송되어지고 디스플레이에 표시되었다. 영상의 질을 평가하기 위하여 PSNR을 계산하였으며, 전송품질을 측정하기 위하여 차량의 속도에 따른 CDMA2000 1X-EVDO의 전송률 및 영상의 전송속도를 측정하였다.

Keywords