• Title/Summary/Keyword: 의료선

Search Result 630, Processing Time 0.036 seconds

Detecting Regions of Stenosis and Aneurysm in a 3D Blood Vessel Model (3차원 혈관 모델에서 협착 및 팽창 영역 탐색 방안)

  • Park, Sang-Jin;Kim, Jae-Sung;Park, Hyungjun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.113-120
    • /
    • 2018
  • Angiography and CT angiography are used widely for the examination of vascular diseases, but the diagnosis of such diseases is made mostly by the subjective judgment of the inspector. This paper proposes a method for detecting the suspicious regions of stenosis and aneurysm in the inner surfaces of 3D blood vessel models reconstructed from medical images. Initially, the 3D curve-skeletons of the blood vessel models and the contours at the nodes of the curve-skeletons were generated. Next, the 3D curve-skeletons were divided into a set of branches and the areas of normal contours of nodes located in each branch were calculated. The nodes whose contours contain suspicious regions were detected by taking into account the average area, maximum and minimum areas, and the area difference between the adjacent normal contours. The diagnosis of stenosis and aneurysm can be supported by properly visualizing the suspicious regions detected. The suspicious regions of the disease were identified by implementing and testing it using several data sets of human blood vessels, highlighting the usefulness of the proposed method.

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.

A Study on the Characteristics of Smartphone Camera as a Medical Radiation Detector (의료 방사선 검출기로써 스마트폰 카메라의 특성에 관한 연구)

  • Kang, Han Gyu;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.5
    • /
    • pp.143-151
    • /
    • 2016
  • The aim of this study is to investigate the optimal algorithm to extract medical radiation induced pixel signal from complementary metal-oxide semiconductor (CMOS) sensors of smartphones camera. The pixel intensity and pixel number of smartphone camera were measured as the X-ray dose was increased. The front camera of the smartphone camera has low noise property and excellent dose response as compared to the back camera of the smartphone. The indirect method which uses scintillation crystal in front of the smartphone camera, couldn't improve the X-ray detection efficiency as compared to the direct method which does not use any scintillator in front of the smartphone camera. When we used the algorithm which employing threshold level on the pixel intensity and pixel number, the dose linearity was more higher for the pixel intensity rather for the pixel number. The use of pixel intensity of Y color component which represents the grey scale, would be efficient in terms of the radiation detection efficiency and reducing the complexity of the image processing. We expect that the radiation dose monitoring can be managed effectively and systematically by using the proposed radiation detection algorithm, thus eventually will contribute to the public healthcare.

Development of Elbow Joint X-ray Examination Aid for Medical Imaging Diagnosis (의료영상 진단을 위한 팔꿉관절 X-선 검사 보조기구 개발)

  • Hyeong-Gyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.127-133
    • /
    • 2024
  • The elbow joint is made up of three different bones. X-rays or other radiological exams are commonly used to diagnose elbow injuries or disorders caused by physical activity and external forces. Previous research on the elbow joint reported a new examination method that meets the imaging evaluation criteria in the tilt position by Z-axis elevation of the forearm. Therefore, this study aims to design an optimized instrument and develop an aid applicable to other upper extremity exams. After completing the 2D drawing and 3D modeling design, the final design divided into four parts was fabricated with a 3D printer using ABS plastic and assembled. The developed examination aid consists of a four-stage Z-axis elevation tilt angle function (0°, 5°, 10°, and 15°) and can rotate and fixate 360° in 1-degree increments. It was designed to withstand a maximum equivalent stress of 56.107 Pa and a displacement of 1.6548e-5 mm through structural analysis to address loading issues caused by cumulative frequency of use and physical utilization. In addition to X-ray exams of the elbow joint, the developed aid can be used for shoulder function tests by rotating the humerus and also be applied to MRI and CT exams as it is made of non-metallic materials. It will contribute to the accuracy and efficiency of medical imaging diagnosis through clinical applications of various devices and medical imaging exams in the future.

A Study for Establishment of Diagnostic Reference Level of Patient Dose in Skull Radiography (우리나라의 두부 엑스선검사에서의 환자선량 권고량)

  • Lee, Jung-Eun;Jeong, Jin-Baek;Lee, Hyun-Koo;Lim, Chun-Il;Son, Hye-Kyung;Jin, Hyun-Mi;Kim, Byung-Woo;Yang, Hyun-Kyu;Kim, Hyeog-Ju;Kim, Dong-Sup;Lee, Kwang-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.111-116
    • /
    • 2010
  • Ionizing radiation is most widely used for X-Ray examination among all artificial radiation exposure, it takes up the largest proportion. Even in Korea, the medical exposure by diagnostic X-Ray examination takes up 17.4% of all radiation exposure. It takes up 92% even in artificial radiation exposure. There were 111,567 cases X-Ray radiography for skull diagnosis in 2007, which is 3% annual increase since 2004. Thus, It is need to establish the diagnostic reference level and the medical facilities as a diagnostic reference level to optimize radiation protection of the patients and to reduce the doses of X-ray. In this paper, we survey patient dose on skull radiography - collected from 114 medical facilities nationwide by using human phantom and glass dosimeter. When the patient dose for the skull radiography was measured and evaluated to establish the diagnostic reference level, 2.23 mGy was established for posterior-anterior imaging and 1.87 mGy for lateral imaging was established. The posterior-anterior skull radiography entrance surface dose of 2.23 is less than the guidance level of 5 mGy from the global organizations such as World Health Organization (WHO) and International Atomic Energy Agency (IAEA), and 1.87 mGy for the lateral skull imaging is less than the guidance level of 3 mGy, which is guided by the global organizations such as World Health Organization (WHO) and International Atomic Energy Agency (IAEA).

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

A Study on the Local Governments' Autonomous Laws Regulating Social Insurance Premium for Medical Security (의료보장을 위한 지방정부의 사회보험료 지원 자치법규에 관한 고찰)

  • Kim, Jesun
    • The Korean Society of Law and Medicine
    • /
    • v.20 no.1
    • /
    • pp.203-242
    • /
    • 2019
  • Since 2006, local governments in Korea have been providing premiums for social insurance, such as the National Health Insurance System, for the health care of local residents. The purpose of this study is to analyze the content of self-governing legislation that defines these policies. The method of conducting the research was based on the articles of the ordinance related to the 'public health insurance premium' of the self-governing statutes published on the website of the National Law Information Center. As of May 2019, 201 municipalities have enacted ordinances to support public health insurance premiums. In the case of state local governments, 8 out of 17 were found, and in the case of basic local governments, 193 out of 226. The constitution of the ordinance consisted of purpose, time of enactment, type of social insurance premium, object of social insurance premium, amount of social insurance premium support, method and process of social insurance premium support, time of social insurance premium support. This study analyzed contents of these articles. Finally, this study presented issues that could be controversial from the policy and legal viewpoints and suggestions for improvement.

Review of 2013 Major Medical Decisions (2013년 주요 의료 판결 분석)

  • Lee, Dong Pil;Jeong, Hye Seung;Lee, Jung Sun;Yoo, Hyun Jung
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.1
    • /
    • pp.263-302
    • /
    • 2014
  • The court handed down meaningful rulings related to medical sectors in 2013. This paper presents the ruling that the care workers could be the performance assistants of the care-giving service although the duties of care worker are not included in the liability stipulated in the medical contract signed with the hospital for reason of clear distinction of duties between care workers and nurses within the hospital in connection with the contract which was entered into between the hospital and patients. In relation to negligence and causal relationship, the court recognized medical negligence associated with the failure to detect the brain tumor due to the negligent interpretation of MRI findings while rejecting the causal relationship with consequential cerebral hemorrhage. The court also recognized negligence based on the observation on the grounds of inadequate medical records in a case involving the hypoxic brain damage caused during the cosmetic surgery. In terms of the scope of compensation for damages, this paper presents the ruling that the compensation should be estimated based on causal relationship only in case the breach of the 'obligation of explanation' is recognized, however rejecting the reparation for de factor property damages in the form of compensation, and the ruling that the lawsuit could be instituted in case that the damages exceeded the agreed scope despite the agreement that the hospital would not be held responsible for any aftereffects of surgery from the standpoint of lawsuit, along with the ruling that recognized the daily net income by reflecting the unique circumstances faced by individual students of Korean National Police University and artists of Western painting. Many rulings were handed down with respect to medical certificate, prescription, etc., in 2013. This paper introduced the ruling which mentioned the scope of medical certificate, the ruling that related to whether the diagnosis over the phone at the issuance of prescription could constitute the direct diagnosis of patient, along with the ruling that required the medical certificate to be generated in the name of doctor who diagnosed the patients, and the ruling which proclaimed that it would constitute the breach of Medical Act if the prescription was issued to the patients who were not diagnosed. Moreover, this paper also introduced the ruling that related to whether the National Health Insurance Service could make claim to the hospitals for the reimbursement of the health insurance money paid to pharmacies based on the prescription in the event that the hospitals provided prescription of drugs to outpatients in violation of the laws and regulations.

  • PDF

A Study on Medical Waste Generation Analysis during Outbreak of Massive Infectious Diseases (대규모 감염병 발병에 따른 의료폐기물 발생량 예측에 관한 연구)

  • Sang-Min Kim;Jin-Kyu Park;In-Beom Ko;Byung-Sun Lee;Sang-Ryong Shin;Nam-Hoon Lee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.31 no.4
    • /
    • pp.29-39
    • /
    • 2023
  • In this study, an analysis of medical waste generation characteristics was conducted, differentiating between ordinary situation and the outbreaks of massive infectious diseases. During ordinary situation, prediction models for medical waste quantities by type, general medical waste(G-MW), hazardous medical waste(H-MW), infectious medical waste(I-MW), were established through regression analysis, with all significance values (p) being <0.0001, indicating statistical significance. The determination coefficient(R2) values for prediction models of each category were analyzed as follows : I-MW(R2=0.9943) > G-MW(R2=0.9817) > H-MW(R2=0.9310). Additionally, factors such as GDP(G-MW), the number of medical institutions (H-MW), and the elderly population ratio(I-MW), utilized as influencing factors and consistent with previous literature, showed high correlations. The total MW generation, evaluated by combining each model, had an MAE of 2,615 and RMSE of 3,353. This indicated accuracy levels similar to the medical waste models of H-MW(2,491, 2,890) and I-MW(2,291, 3,267). Due to limitations in accurately estimating the quantity of medical waste during the rapid and outbreaks of massive infectious diseases, the generation unit of I-MW was derived to analyze its characteristics. During the early unstable stage of infectious disease outbreaks, the generation unit was 8.74 kg/capita·day, 2.69 kg/capita·day during the stable stage, and an average of 0.08 kg/capita·day during the reduction stage. Correlation analysis between generation unit of I-MW and lethality rates showed +0.99 in the unstable stage, +0.52 in the stable stage, and +0.96 in the reduction period, demonstrating a very high positive correlation of +0.95 or higher throughout the entire outbreaks of massive infectious diseases. The results derived from this study are expected to play a useful role in establishing an effective medical waste management system in the field of health care.

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.