• Title/Summary/Keyword: 의료선

Search Result 624, Processing Time 0.02 seconds

A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography (산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.345-353
    • /
    • 2021
  • Digital radiography imaging systems can also help diagnose lesions in patients, but if x-rays that enter the human body cause scatter x-ray due to interaction with substances, they affect the signal and noise characteristics of digital x-ray images. To regard the human body as polymethyl methacrylate (PMMA) and observe the properties of scattered x-ray generated from PMMA on x-ray images, we analyze signal and noise in the spatial domain as well as noise-power spectrum (NPS), and detective quantum efficiency (DQE) at zero frequency. As PMMA thickness increased, signals decreased, the noise increased, and NPS degradation was identified in overall spatial frequencies. Based on these characteristics, zero-frequency performance was also shown to be degraded. Comparative analysis with Monte-carlo simulations will need to be made to analyze the zero-frequency performance by scattered x-ray of indirect conversion-type x-ray detectors more quantitatively.

Development of Indirect Dosimetry by Calculation Method in the Diagnostic X-ray Equipment (진단용엑스선촬영장치의 간접 선량 계산법 개발)

  • Kim, Jung-Su;Kim, Sung-Hwan;Jeon, Min-Cheol;Ju, Won-Ha;Jeong, Min-Gyu;Kim, Mi-Jeong;Lee, Seung-Youl;Lee, Tae-Hee;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.587-594
    • /
    • 2018
  • The purpose of this study was to develop the indirect dosimetry by calculation (IDC) method for diagnostic X-ray equipment. The experiments were performed with inverter type X-ray tubes: Toshiba (E7252X, Japan) and Varian (RAD-14, USA). For the development method, we first applied the standard quality of X-ray beam shown in the TRS457 document, and second, to produce the constants of trendline for the IDC, the total filtration on X-ray beam was subdivided. Third, in order to increase the precision, the energy region was divided into the high energy region and the low energy region and developed by the IDC. In order to verify the IDC, mean dose (mR) values were measured for three Toshiba X-ray tubes and three Varian X-ray tubes at clinical medical institutions and then compared with the IDC on the 2013. As a result, compared with the previous study, the accuracy of the IDC of this study were improved by 2.71% and 9.91% in Toshiba and Varian X-ray tubes, respectively.

Effects of Biomedical Ethics Education on Moral sensitivity, Critical thinking and Biomedical ethics Awareness of Nursing Students (생명의료 윤리교육이 간호학생의 도덕적 민감성, 비판적 사고성향, 생명의료 윤리의식에 미치는 효과)

  • Kim, Kyung-Ah;Jeong, Gye-Seon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.240-249
    • /
    • 2019
  • The purpose of this study was to find the effect of systemic biomedical ethics education program on moral sensitivity, critical thinking disposition and consciousness of biomedical ethics nursing student. This study is a quasi-experimental research design and repeated measured ANOVA was used to analyzed the collected data statistically on this study. Data was collected from 1st September to 31 of December 2014. Nursing students and nurses in A and S cities participated in this study as subjects. 32 nursing students were assigned to an experimental group, and 33 nursing students were assigned to control group A, 26 nurses were assigned control group B, total subjects were 91. There are significant different in consciousness of biomedical ethics(F=3.432, p=.037). In the category of consciousness of biomedical ethics, there are significant different in 'right to life of fetus'(F=4.476, p=.014) and 'prenatal diagnosis of fetus'(F=6.207, p=.003), and 'right to life of newborn(F=6.207, p=.003) between experimental group and two control groups. The biomedical ethics education influenced the positive effect on moral sensitivity, critical thinking disposition and consciousness of biomedical ethics of nursing students, and shown the significant effect to enhance the consciousness of biomedical ethics for nursing students.

Development of Unfolding Energy Spectrum with Clinical Linear Accelerator based on Transmission Data (물질투과율 측정정보 기반 의료용 선형가속기의 에너지스펙트럼 유도기술 개발)

  • Choi, Hyun Joon;Park, Hyo Jun;Yoo, Do Hyeon;Kim, Byoung-Chul;Yi, Chul-Young;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.41-47
    • /
    • 2016
  • Background: For the accurate dose assessment in radiation therapy, energy spectrum of the photon beam generated from the linac head is essential. The aim of this study is to develop the technique to accurately unfolding the energy spectrum with the transmission analysis method. Materials and Methods: Clinical linear accelerator and Monet Carlo method was employed to evaluate the transmission signals according to the thickness of the observer material, and then the response function of the ion chamber response was determined with the mono energy beam. Finally the energy spectrum was unfolded with HEPROW program. Elekta Synergy Flatform and Geant4 tool kits was used in this study. Results and Discussion: In the comparison between calculated and measured transmission signals using aluminum alloy as an attenuator, root mean squared error was 0.43%. In the comparison between unfolded spectrum using HEPROW program and calculated spectrum using Geant4, the difference of peak and mean energy were 0.066 and 0.03 MeV, respectively. However, for the accurate prediction of the energy spectrum, additional experiment with various type of material and improvement of the unfolding program is required. Conclusion: In this research, it is demonstrated that unfolding spectra technique could be used in megavoltage photon beam with aluminum alloy and HEPROW program.

Radiation Protection Effect of Selenium on the Rat's Prostate (흰쥐의 전립선에 대한 셀레늄(Se)의 방사선 방호효과)

  • Choi, Hyung-Seok;Choi, Jun-Hyeok;Jung, Do-Young;Kim, Jang-Oh;Shin, Ji-Hye;Kim, Joo-Hee;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.317-322
    • /
    • 2017
  • High-tech medical equipment has increased the utilization of radiation in the medical field. As a result, research on radiation protection using natural materials has become an important social issue. Selenium is a natural substance that is highly expressed in prostate known that an essential role in prostate cells. Selenium was orally administered to Rat and irradiated with 10 Gy of radiation. Then, the prostate tissue w as used as a target organ for 1 day, 7 days and 21 days to investigate the radiation protection effect of selenium through changes of blood components, Superoxide Dismutase and histological changes. As a result, there was a significant protective effect of hematopoietic immune system(hemoglobin concentration, neutrophil, platelet) in the group irradiated with selenium(p<0.05). the observation of tissue changes selenium is an effective component to increase Superoxide Dismutase activity, and it was confirmed that it has an effect of inhibiting the expression of hypertrophy of prostate by irradiation. Therefore, it is considered that selenium can be utilized as a radioprotective agent by inducing prevention of prostate-related diseases.

Application of Picture Book Reading Training Protocol using Electronic Media and Its Effects on Reading Ability for to Borderline Intellectual Children (경계선 지능 아동을 대상으로 전자매체를 활용한 그림책 읽기 훈련 프로토콜의 적용 및 읽기능력에 미치는 영향)

  • Son, Sung-Min;Kwag, Sung-Won;Jeon, Byoung-Jin
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.8 no.3
    • /
    • pp.25-35
    • /
    • 2018
  • Objective : The purpose of this study was to identify changes in reading ability among children with Borderline Intelligence by applying an electronic media reading training protocol. Methods : A picture book reading training protocol was applied to 10 childrens with borderline intelligence using electronic media to improve reading skills. This protocol was performed for 10 session once a week. After the analysis of the content validity index about the protocol presented in this study, this prococol was applied to the subjects. To analyze the changes of the reading ability for the subjects, KNISE-BAAT type A and B reading test were used. Results : According to the tests taken before and after implementing, the Application of Picture Booking Training Protocol using Electronic Media there was a significant improvement in Reading ability (Understanding words, Completion sentence, Vocabulary selection, Vocabulary arrangement, Understanding short text). However, there was no significant difference in Oral Reading. Conclusion : Application of Picture Booking Training Protocol using Electronic Media may be used as a beneficial measure to improve the reading abilities of children with Borderline Intellectual.

Calculation of Shielding Rate of Radiation Protective Equipment Using the X-ray Spectrum of IPEM Report-78 (IPEM Report-78의 엑스선 스펙트럼을 이용한 방사선 방호장비의 차폐율 계산)

  • Han, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.755-760
    • /
    • 2021
  • In this study, the shielding rate of major X-ray protective equipment used in the medical environment was calculated using X-ray spectrum data emitted from the diagnostic X-ray generator of The Institute of Physics and Engineering(IPEM) Report-78, and the applicability of radiation protection was investigated. Radiation shielding rates were calculated through reduction rates of air-kerma and total intensity for lead apron (0.3 mmPb), thyroid shield (0.5 mmPb), lead goggles (0.5 mmPb), and lead glass (1.8, 2.7, 3.3 mmPb) used for diagnostic X-ray protection. As a result, the shielding rate calculated as the air kerma reduction rate ranged from 96.31 to 100% at 80 kV, and 90.35 to 100% at 120 kV. In addition, the results of this calculation were well matched with the results of previous studies measuring the actual shielding rate, and it is expected that the X-ray spectrum data of IPEM Report-78 can be used for radiation protection.

A Study on Environment, Care Process, and Patient-related Factors Associated with Patient Falls - A Retrospective Study of Inpatient Falls in the Unit of General Medicine in the United States (환자낙상에 영향을 주는 환경, 의료과정, 그리고 환자 관련 요소에 관한 연구 - 미국의 일반내과병동 환자낙상 데이터 분석을 통한 후향성 연구)

  • Choi, Young-Seon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2018
  • Purpose: The main objective of this paper is, to assess environment, care process, and patient-related factors associated with patient falls. The study also aims at identifying various factors that would affect inpatient falls and, therefore, helping both caregivers and designers contribute to better prevent inpatient falls in their own areas of expertise. Methods: A retrospective analysis of inpatient falls that occurred in the unit of General Medicine in the United States has been conducted and environment, care process, patient-related factors associated with those falls have been analyzed at the same time. Results: The study identified several factors associated with inpatient falls. They range from environmental factors to care process- and patient-related factors. Patient visibility and patient accessibility can matter to patient falls and where those falls occur, along with patient days per room, the percentage of patient days with high fall risk patients per room, the percentage of high fall risk patients per room. Implications: The findings of the study can provide design implications that can be incorporated into design process and design decisions to promote fall prevention in inpatient care units. Inpatient falls can be effectively reduced when caregivers and designers work together to understand the complex nature of inpatient falls and the importance of multidisplinary efforts among various experts in the areas of healthcare.

Review of 2012 Major Medical Decisions (2012년 주요 의료 판결 분석)

  • Lee, Jung Sun;Lee, Dong Pil;Yoo, Hyun Jung;Jeong, Hye Seung
    • The Korean Society of Law and Medicine
    • /
    • v.14 no.1
    • /
    • pp.303-354
    • /
    • 2013
  • In 2012, the major jurisdictions regarding medical cases caused the controversial issues towards medical and legal fields by getting the judgments from the Supreme Court, which admitted the exceptional admissibility on discretionary grant. By regarding the serial negligence of medical organizations as a separate tort, the sentences which made up irrationality, were spoken by the court. As a result, if the treatment was made, which did not follow the entered matters in medical documents attached, the court announced the jurisdiction that presumes the negligence, which provided the evidence of negligence; on the other hand, this gave had the burden to medical branch to take great care for medicinal treatment. To be applicable for the Principle of Trust, the doctors have to give and take the necessary information for the treatment process and symptom decisions, which also commented in the court. Thus, this case made it difficult to apply the Principle of Trust and considered all the conditions as tough ones, which eventually induced lesser faults for patients' care. Moreover, the court confirmed that the medical ads sending the emails to the members belong to the internet portal sites, are not the inducing behavior by considering that the actions are only medical ads. Furthermore, in the case of Namsu Kim, the court's interpretation was rather limited the definition for medical practice that announced limited Erweiterung der Strafbarkeit cases by lower courts. As a consequence, it is very interesting whether the Supreme Court may change their position and concerning the duty of explanation, the trend to expand the contents and scopes for the duty of explanation continues by admitting instruction explanation obligation and all the compensations and so on.

  • PDF

A Study on Radiation Dose and Image Quality according to CT Table Height in Brain CT (두부 CT 검사 시 테이블 높이에 따른 선량과 화질에 관한 연구)

  • Ki-Won Kim;Joo-Young Oh;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Kyung-Hwan Lim;Yun Yi
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.99-106
    • /
    • 2023
  • The height of the table should be considered important during computed tomography (CT) examination, but according to previous studies, not all radiology technologists set the table at the patient's center at the examination, which affects the exposure dose and image quality received by the patient. Therefore, this study intends to study the image quality exposure dose according to the height of the table to realize the optimal image quality and dose during the brain CT scan. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. For the exposure dose measurement, optically stimulated luminescence dosimeter (OSLD) was attached to the front, side, eye, and thyroid gland of the head phantom. In the signal to noise ratio (SNR) measurement result, The SNR values for each table height were all lower than 915 mm. As a result of exposure dose, the exposure dose on each area increased as the table height decreased. The height of the table has a close relationship with the patient's radiation exposure dose in the CT scan.