Calculation of Shielding Rate of Radiation Protective Equipment Using the X-ray Spectrum of IPEM Report-78  

Han, Dong-Hyun (The Korean Society of Radiology Education Institute)
Publication Information
Journal of the Korean Society of Radiology / v.15, no.5, 2021 , pp. 755-760 More about this Journal
Abstract
In this study, the shielding rate of major X-ray protective equipment used in the medical environment was calculated using X-ray spectrum data emitted from the diagnostic X-ray generator of The Institute of Physics and Engineering(IPEM) Report-78, and the applicability of radiation protection was investigated. Radiation shielding rates were calculated through reduction rates of air-kerma and total intensity for lead apron (0.3 mmPb), thyroid shield (0.5 mmPb), lead goggles (0.5 mmPb), and lead glass (1.8, 2.7, 3.3 mmPb) used for diagnostic X-ray protection. As a result, the shielding rate calculated as the air kerma reduction rate ranged from 96.31 to 100% at 80 kV, and 90.35 to 100% at 120 kV. In addition, the results of this calculation were well matched with the results of previous studies measuring the actual shielding rate, and it is expected that the X-ray spectrum data of IPEM Report-78 can be used for radiation protection.
Keywords
IPEM Report-78; X-ray Spectrum; Radiation Protection; Shielding Rate;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 J. S. Song, "A Study on the Development of Optimization Procedure for Radiological Protection", Journal of Radiation Protection and Research, Vol. 19, No. 1, pp. 1-4, 1994.
2 Y. S. Park, J. S. Yoo, D. Y. Kim, Medical Radiation Management, ShinKwang Publisher, pp. 73-100, 1992.
3 J. I. Yoo, J. W. Koo, "Musculoskeletal Symptoms and Related Factors for Nurses and Radiological Technologists Wearing a Lead Apron for Radiation Protection", Annals of Occupational and Environmental Medicine, Vol. 16, No. 2, pp. 166-177, 2004.
4 L. Ben Omrane, F. Verhaegen, N. Chahed, S. Mtimet, "An investigation of entrance surface dose calculations for diagnostic radiology using Monte Carlo simulations and radiotherapy dosimetry formalisms", Physics in Medicine and Biology, Vol. 48, No. 12, pp. 1809-1824, 2003. http://dx.doi.org/10.1088/0031-9155/48/12/310   DOI
5 J. N. Song, G. W. Seol, S. G. Hong, J. G. Choi, "A Study on Protection Performance of Radiation Protective Aprons classified by Manufacturers and Lead Equivalent using Over Tube Type Fluoroscopy", Journal of the Korean Society of Radiolog, Vol. 5, No. 3, pp. 135-141, 2011. https://doi.org/10.7742/jksr.2011.5.3.135   DOI
6 F. Verhaegen, A. E. Nahum, S. Van de Putte, Y. Namito, "Monte Carlo modelling of radiotherapy kV x-ray units", Physics in Medicine and Biology, Vol. 44, No. 7, pp. 1767-1789, 1999. https://doi.org/10.1088/0031-9155/44/7/315   DOI
7 J. H. Hubbell, S. M. Seltzer, "Tables of X-ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients", National Institute of Standards and Technology(NIST), 1999.
8 Ministry of Health and Welfare, "Rules on Safety Management of Diagnostic Radiation Generating Device"s, Ordinance No. 185 of the Ministry of Health and Welfare, 2013.
9 R. J. Vetter, "Medical Health Physics a review", Health Physics, Vol. 88. No. 6, 653-664, 2005. https://doi.org/10.1097/00004032-200506000-00010   DOI
10 Cranley K, et al, "IPEM Report 78, Catalogue of Diagnostic X-ray Spectra and Other Data(CD-Rom Edition 1997) (Eletronic Version prepared by D sutton)", The Institute of Physics and Engineering in Medicine, 1997.
11 ICRP, "Radiation Protection and Safety in Medical Care", Publications 73, pp. 6-10, 1998.
12 Korea Standard, "The lead equivalent test method of X-ray protective equipment", KS A 4025, 1990.
13 K. W. Kim, S. H. Choi, K. Y. Kim, I. P. Lee, S. G. Hwang, K. R. Dong, "Performance Evaluation of Aprons according to Lead Equivalent and Form Types", Journal of Radiation Industry, Vol. 10, No. 4, pp. 219-225, 2016. http://dx.doi.org/10.23042/radin.2016.10.4.219   DOI