References
- Kimme-Smith C, Aberle DR, Sayre JW, Hart EM, Greaves SM, Brown K, et al. Effects of reduced exposure on computed radiography: comparison of nodule detection accuracy with conventional and asymmetric screen-film radiographs of a chest phantom. American Journal of Roentgenology, 1995;165(2):269-73. https://doi.org/10.2214/ajr.165.2.7618538
- Al Khalifah K, Brindhaban A. Comparison between conventional radiography and digital radiography for various kVp and mAs settings using a pelvic phantom. Radiography. 2004;10(2):119-25. https://doi.org/10.1016/j.radi.2004.02.006
- Van Metter R, Yorkston J. Applying a proposed definition for receptor dose to digital projection images. In: Medical imaging 2006: physics of medical imaging. San Diego, CA: SPIE; 2006, 6142.
- Seibert JA, Shelton DK, Moore EH. Computed radiography x-ray exposure trends. Acad Radiol, 1996;4:313-8.
- IEC 60601-2-54:2009/AMD1:2015, Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy; 2015.
- Hanan FA. Assessment of Entrance skin dose and effective dose of some routine Examinations using calculation technique. King Saud University; 2007.
- Suchart K, Montree T. An Estimation of X-Radiation Output using Mathematic Model. American Journal of Applied Sciences. 2011;8(9):923-6. https://doi.org/10.3844/ajassp.2011.923.926
- Sung DW. National Based Research of Patient Radiation National Based Research of Patient Radiation. The Report of Korea Food & Drug Administration; 2013.
- IEC 61267:2005, Medical diagnostic X-ray equipment - Radiations conditions for use in the determination of characteristics, Geneva.
- IEC 61674:2012, Medical electrical equipment - Dosimeters with ionization chambers and/or semiconductor detectors as used in X-ray diagnostic imaging. 2012. Oct. 24. 2018. Accessed at https://webstore.iec.ch/publication/5711
- Seoung YH. Evaluation of Accuracy and Reproducibility of Clinical General X-ray System by Safety Management Standard of Diagnostic Radiation Generators. J. Health. Med. Sci., Cheongju Univ. 2018;6(2):41-8.
- Duong VT, Ho QT, Bui DK. Establishing the standard X-ray beam qualities for calibration of dosimeters used in diagnostic radiology following IAEA-TRS457. No. VINATOM-AR-13. 2014.
- Suchart K, Montree T. An Estimation of X-Radiation Output using Mathematic Model. American Journal of Applied Sciences. 2011;8(9):923-6. https://doi.org/10.3844/ajassp.2011.923.926
- Roh YH, Kim JM, The Tendency of Medical Electrical Equipment - IEC 60601-2-54: Particular Requirements for the Basic Safety and Essential Performance of X-ray Equipment for Radiography and Radioscopy. J. Radiological Science & Technology. 2015;38(4):331-6. https://doi.org/10.17946/JRST.2015.38.4.01
- Technical White Paper: Monitoring and Tracking of Fluoroscopic Dose, CRCPD Publication #E-10-7, 2010.
- Mori T, et al. The Calculation and Measurement of an Entrances Surface Dose in Diagnostic X-ray. Committee of Radiation Protection (NDD group) in the Ibaragi branch of Japanese Society of Radiological Technology; 1984.
- Edmonds IR. Calculation of patient skin dose from diagnostic X-ray procedures. The British journal of radiology. 1984;57(680):733-4. https://doi.org/10.1259/0007-1285-57-680-733
- Tung CJ, Tsai HY. Evaluations of gonad and fetal doses for diagnostic radiology. Proc Nat Sci Counc Repub China B. 1999;23(3):107-13.
- Suzuki M, et al. The Expression for an Entrances Surface Dose of Patients in Diagnostic X-ray-NDD Method. Committee of Radiation Protection in the Ibaragi branch of Japanese Society of Radiological Technology; 1996.
- Kim SC, Kim CY, Ahn SM. Calculation Method of Entrance Skin Dose in X-ray Beam Quality Factor. Jour. of KoCon. 2010;10(2):258-67.
- Sung HJ, Han JB, Song JN, Choi NG. Entrance Surface Dose according to Dose Calculation: Head and Wrist. J. Radiological Science & Technology. 2016;39(3):305-12. https://doi.org/10.17946/JRST.2016.39.3.02
- Brosi P, Stuessi A, Verdun FR, et al. Copper filtration in pediatric digital X-ray imaging: its impact on image quality and dose. Radiol Phys Technol. 2011;4:148-55. https://doi.org/10.1007/s12194-011-0115-4
- Han JB, Choi NG, Sung HJ. Comparative Study of Radiation Exposure using Entrance Skin Dose Calculation Technique in Diagnostic X-Ray Radiography. Jour. of KoCon. 2011;11(12):357-63.