• Title/Summary/Keyword: 응집제 주입농도

Search Result 64, Processing Time 0.021 seconds

Alum$\cdot$철염 응집제의 응집효과 비교

  • 안현화;황병기;이상호
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2000.05a
    • /
    • pp.126-127
    • /
    • 2000
  • Fe(III) 응집제는 pH 5~9범위에서 Al(III)계 응집제보다 보다 우수한 응집효과를 보였으며 또한 pH의 영향을 거의 받지 않는 것으로 나타났다. 잔류 Fe의 경우 응집제 주입농도와 pH 증가에 영향을 거의 받지 않고 저농도의 잔류 Fe농도를 나타낸 반면, Al(III) 응집제는 잔류 Al의 급격한 증가를 나타내었다.

  • PDF

Evaluation of Coagulation-UF Process Considering Residual Aluminuim Concentration as Seawater Desalination Pretreatment (해수담수화 전처리 공정으로써 잔류 알루미늄 농도를 고려한 응집-UF 공정 연구)

  • Son, Dong-Min;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.495-502
    • /
    • 2013
  • This work was performed to investigate proper condition of coagulation treatment as UF process pretreatment that consider UF permeate flux and residual Al concentration. The coagulant used an alum as $Al_2(SO_4)_3{\cdot}16H_2O$ and PACl (r = 1.5) made this study. The experiment was tested in adjusting conditions such as alum dose, flocculation time and coagulation pH of seawater. Consequently, higher coagulant dose lead to elevation of UF permeate flux while residual aluminium also increased in condition of pH 8.0. The most suitable condition which has a good permeate flux and low residual aluminium, in this works, was coagulant dose of 0.7 mg/L (as Al, alum) and 1.2 mg/L (as Al, PACl) and coagulation pH 6.5. In addition, applying the flocculation time with 1.2 mg/L of PACI reduced. The flocculation time reduced UF permeate flux in using alum.

Determination of Optimun Coagulant Dosage for Effective Water Treatment of Chinyang Lake -The Effect of Coagulant Dosing on Remoaval of Colloidal Pollutants- (진양호소수의 효과적인 정수처리를 위한 최적응집제 주입량 결정 -콜로이드성 오염물질 처리를 위한 응집제 주입효과-)

  • 이원규;조주식;이홍재;허종수
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.761-772
    • /
    • 1998
  • This study was performed to determine the optimum coagulant dosing amount for effective treatment of raw water. The removal rate of turbidity and the variations of water qualities according to various dosage of coagulants such as Alum, PAC and PACS were investigated. The optimum coagulant dosing amount to make the lowest turbidity of water were 35mg/ι t of Alum, 30mg/ι of PAC and 10mg/ι of PACS in case of 5 NTU of raw water turbidity, and 30mg/ι of Alum, 25mg/ι of PAC and 10mg/ι of PACS in case of 10 NTU of that, respectively. The removal rates of turbidity at 4 min. and 8 min. of settling time were 10 and 72% of Alum, 44 and 62% of PAC and 25 and 55% of PACS in case of 5 NTU, and 52 and 70% of Alum, 90 and 95% of PAC and 10 and 28% of PACS in case of 10 NTU, respectively. Judging from the settling capability of floc., the reaction time of floe. formation and removal efficiency of turbidity, PAC was evaluated as more effective coagulant than Alum and PACS. Also PAC was regarded as the most effective coagulant when the water supply was changed sharply and the fluctuation of the surface loading occured with wide and sharp in settling basin. pH and alkalinity of the water were decreased with increasing coagulants dosage. But pH and alkalinity were not decreased below 5.8 which is the standard for drinking water quality, and 10mg/ι which is the limit concentration of floc. breakage, respectively. Residual Al of the treated water was decreased with increasing coagulants dosage in case of 5 and 10NTU of raw water turbidity. $KMnO_4$ consumption of the water was decreased with increasing coagulants dosage. The reduction rate of $KMnO_4$ consumption at the optimum coagulants dosage were 39% of Alum. 18% of PAC and 11% of PACS in case of 5 NTU of raw water turbidity, and 42% of Alum, 27% of PAC and 36% of PACS in case of 10 NTU of that, respectively. Any relationship was not found between the removal rate of turbidity and KMnO$_4$ consumption. TOC of the water was a bit decreased with increasing coagulants dosage up to 30mg/ι but not changed above 30mg/ι of coagulants dosage. The degree of TOC reduction was increased in the order of Alum, PAC and PACS treatment. Zeta potential of the colloidal floe. at the optimum coagulants dosage was in the range of -20~-15mV in case of 5 NTU of raw water turbidity and 0~0.5mV in case of 10 NTU of that. respectively. Although the kinds and dosages of coagulants were different, zeta potential range were fixed under the conditions of the best coagulation efficiency.

  • PDF

A Study on Solid-liquid Separation of Swine Wastewater Using Coagulation and Dissolved Air Flotation (응집침전 및 부상분리에 의한 돈사폐수의 고액분리에 관한 연구)

  • Kim, Jong-Oh;Jeong, Seong-Uk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.12 no.2
    • /
    • pp.101-109
    • /
    • 2004
  • In this study, the solid-liquid separation characteristics of swine wastewater were investigated for the coagulation and dissolved air flotation (DAF). Coagulation characteristics were studied using jar-tester with the different coagulants and dosage amounts. DAF characteristics were also investigated in terms of the different flotation conditions with the raw swine wastewater, pH adjustment only, and adding coagulants. When the raw swine wastewater was coagulated with the only inorganic coagulants, the proper inorganic coagulants were founded as $FeCl_3$ > PAC > Alum orderly, and the optimal coagulant dosages were founded as $1,000mg/{\ell}$, $1,500mg/{\ell}$, $1,500mg/{\ell}$, respectively. As the raw swine wastewater was treated with the polymer coagulants, the only cationic polymer coagulant showed an effective coagulation and the optimal dosage of cationic coagulant was founded as $200mg/{\ell}$. When the different dosages of cationic polymer was added to each $500mg/{\ell}$ of the inorganic coagulants, the proper inorganic coagulants were founded as $FeCl_3$ > Alum > PAC orderly, and optimal cationic polymer dosages was founded as $25mg/{\ell}$, $25mg/{\ell}$, and $100mg/{\ell}$, respectively. Resulting from the raw swine wastewater experiments using DAF without coagulation, the proper operation conditions of DAF were set to 400% of recycling ratio, 4 atm in air dissolving tank, and under pH 3. But the raw swine wastewater was difficult to successfully operate DAF without pre-coagulation. While the DAF separation after pre-coagulation using inorganic coagulants was not accomplished due to the low intensity of the floc, DAF after pre-coagulation using both the inorganic and cationic polymer coagulants was accomplished very well. Optimal dosage of cationic polymer coagulant in case of $500mg/{\ell}$ Alum dosage was founded as $500mg/{\ell}$.

  • PDF

Effect of pH Adjustment by CO2 on Coagulation and Aluminum Elution in Water Treatment (CO2 주입에 의한 pH 조정이 정수장 응집효율 및 알루미늄 용출에 미치는 영향)

  • Lee, Gil-Seong;Kim, Min-Chai;Kwon, Jae-Kook;Seo, Gyu-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.17-22
    • /
    • 2013
  • In this study, a pH control method by carbon dioxide ($CO_2$) was applied to coagulation process in water treatment plant (WTP) to investigate the coagulation efficiency and residual dissolved aluminum when high pH raw water is flowing into the plant during algal blooming. Existing coagulant dose (1 mg/L in raw water) resulted in the pH reduction of 0.0384 by LAS, 0.0254 by PAC, 0.0201 by A-PAC, and 0.0135 by PACS2, respectively. And then the concentration of dissolved aluminum was 0.02 mg/L at pH 7.44, 0.07 mg/L at pH 7.96, 0.12 mg/L at pH 8.16, 0.39 mg/L at pH 8.38 showing the concentration increase with pH in the coagulation process. It was noteworthy that rapid increase was observed at pH above 8.0 next the rapid mixing. Therefore it is necessarily required to control pH below 7.8 in the coagulation process in order to meet drinking water quality standard of aluminum for high pH raw water into WTP, $CO_2$ injection could control pH successfully at about 7.3 even for the raw water of high pH above 8.0. In addition it was found that the pH control by $CO_2$ injection was significantly effective for coagulation in terms of turbidity removal, coagulant dosage, and residual dissolved aluminum concentration.

Decision Algorithm of Natural Algae Coagulant Dose to Control Algae from the Influent of Water Works (정수장 유입조류 전처리를 위한 천연조류제거제(W.H.)의 최적주입농도 결정)

  • Jang, Yeo-Ju;Jung, Jin-Hong;Lim, Hyun-Man;Yoon, Young H.;Ahn, Kwang-Ho;Chang, Hyang-Youn;Kim, Weon-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.9
    • /
    • pp.482-496
    • /
    • 2016
  • Algal blooms of cyanobacteria (blue-green Algae) due to the eutrophication of rivers and lakes can cause not only the damage by its biological toxins but also the economic loss in drinking water treatment. The natural algae coagulant, a commercial product known as W.H. containing the algicidal and allelopathic material derived from oak, can control algal problems proactively through the coagulation flotation process. However, because there have been no applications of the process for pre-treatment in drinking water plants, we could find no report on the optimum injection dose of W.H.. In this study, we have conducted several sets of jar-tests while changing W.H. dose and concentration of chl-a for (1) Han-river samples and (2) subcultured cyanobacteria samples, and monitored the removal mechanisms of algae intensively. Based on these jar-test results, two linear equations with variables of chl-a and turbidity have been deduced to predict the optimal W.H. dose after the multiple regression analysis using IBM-SPSS. Also, prototypes of automatic control logic have been suggested to inject the optimal W.H. dose promptly in response to the variation of water quality.

Effect of Inorganic Coagulants on the Performance of Electro-Chemical Treatment Process Treating Hospital Wastewater (병원폐수의 전기화학적 처리시 무기응집제 주입 효과에 관한 연구)

  • Jeong, Seung-Hyun;Jeong, Byung-Gon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.709-716
    • /
    • 2011
  • Effect of inorganic coagulants dosing on the performance of electro-chemical process was studied when treating hospital wastewater having low electrolyte concentration. It is thought that adding inorganic coagulants caused increase in concentration of electrolyte and this caused increase in free chloride concentration and consequently, caused increase in indirect oxidation effect. Thus, COD removal efficiencies more than doubled in percentage terms at the 2 hrs of reaction time and current density of $1.76A/dm^2$ compared with the results obtained from the parallel experiments without adding inorganic coagulants. T-N removal efficiencies approximately doubled in percentage terms at the 2 hrs of reaction time and 700 ppm of coagulants addition and applied current density of $1.76A/dm^2$ due to the increase of free residual chlorine such as HOCl caused by increase of electrolyte concentration through the addition of inorganic coagulants. Under the same experimental condition, more than 90% of T-P removal efficiencies was obtained. The reason can be explained that increase of chemical adsorption rate between phosphate and insoluble metal compounds caused by dissolved oxygen generated from anode by the increased electrolyte concentration through inorganic coagulants addition make a major role in improving T-P removal efficiencies. It can be concluded that inorganic coagulants addition as the supplemental agent of electrolyte is effective way in improving organic and nutrient salt removal efficiency when treating hospital wastewater having low electrolyte concentration.

Survey of Physicochemical Methods and Economic Analysis of Domestic Wastewater Treatment Plant for Advanced Treatment of Phosphorus Removal (총인 수질기준강화를 위한 국내 하수종말처리장의 물리화학적처리 특성조사 및 경제성 분석)

  • Park, Hye-Young;Park, Sang-Min;Lee, Ki-Cheol;Kwon, Oh-Sang;Yu, Soon-Ju;Kim, Shin-Jo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.212-221
    • /
    • 2011
  • Wastewater treatment plants (WWTPs) are required to meet the reinforced discharge standards which are differentiated as 0.2, 0.3 and 0.5 mg-TP/L for the district I, II and III, respectively. Although most of WWTPs are operating advanced biological phosphorus removal system, the supplementary phosphorus treatment facility using chemical addition should be required almost at all WWTPs. Therefore, water quality data from several exemplary full-scale plants operating phosphorus treatment process were analyzed to evaluate the reliability of removal performance. Additionally, a series of jar tests were conducted to find optimal coagulants dose for phosphorus removal by chemical precipitation and to describe characteristics of the reaction and sludge production. Chemical costs and the increasing sludge volume in physicochemical phosphorus removal process were estimated based on the results of jar tests. The minimum coagulant (aluminium sulfate and poly aluminium chloride) doses to keep TP concentration below 0.5 and 0.2 mg/L were around 25 and 30 mg/L (as $Al_2O_3$), respectively, in the mixed liquor of activated sludge. In the tertiary treatment facility, relatively lower coagulant doses of 1/12~1/3 the minimum doses for activated sludge were required to achieve the same TP concentrations of 0.2~0.5 mg/L. Increase in suspended solids concentration due to chemical precipitates in mixed liquor was estimated at 10~11%, compared to the concentration without chemical addition. When coagulant was added into mixed liquor, chemical (aluminium sulfate) cost was estimated to be 4~10 times higher than in secondary effluent coagulation/separation process. Sludge production to be wasted was also 4~10 times higher than secondary effluent coagulation/separation process.

Removal of Dissolved Organic Nitrogen from Surface Water and Reclaimed Water by Coagulation (지표수 및 재이용수내 용존 유기질소의 응집처리)

  • Lee, Wontae;Choi, June-Seok;Oh, Hyun Je
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.11
    • /
    • pp.729-734
    • /
    • 2012
  • During chlorination processes dissolved organic nitrogen (DON) can form toxic nitrogenous disinfection byproducts and organic chloramines which have little or no bactericidal activity. DON needs to be removed before chlorination processes to reduce the formation of those products. This study investigated the removal of DON from surface water and reclaimed water by coagulation with aluminum sulfate (alum) and a cationic polymer (polyDADMAC). Removal characteristics of dissolved organic carbon (DOC) and ultraviolet absorbance at 254 nm ($UVA_{254}$) were compared with that of DON. Coagulation with alum removed DON, DOC, and $UVA_{254}$ with similar trends, but the removal of $UVA_{254}$ was highest. A dual coagulation strategy of alum and cationic polymer improved the removal of DON. Coagulation with cationic polymer alone was not effective due to its narrow range of charge neutralization. DON in reclaimed water was easier to remove than that in surface water, and higher molecular weight fraction (>10,000 Da) of DON was preferentially removed.

Characteristic of Al(III) Hydrolysis Specie Distribution on Coagulation Process (응집공정에서 발생하는 알루미늄 가수분해종 분포특성)

  • Song, Yu-Kyung;Jung, Chul-Woo;Hwangbo, Bong-Hyung;Sohn, In-Shik
    • Korean Chemical Engineering Research
    • /
    • v.44 no.5
    • /
    • pp.547-554
    • /
    • 2006
  • The overall objective of this research was to find out the role of rapid mixing conditions in the species of hydrolyzed Al(III) formed by Al(III) coagulants and to evaluate the distribution of hydrolyzed Al(III) species by coagulant dose and coagulation pH. When an Al(III) salt was added to water, monomeric Al(III), polymeric Al(III), precipitate Al(III) was formed by Al(III) hydrolysis. The method of hydrolyzed Al(III) species characterization analysis was based on timed spectrophotometer with ferron as a color developing reagent. The hydrolytic species were divided into monomer, polymer, precipitate from the reaction kinetics. And then, the color intensity for monomeric Al(III) was read 3 min after mixing. With standard Al solution containing monomeric Al(III) only, the Al-ferron color intensity slightly increased with until about 3 min. During the rapid mixing period, for purewater, formation of dissolved Al(III) (monomer and polymer) was similar to rapid mixing condition, but for raw water, the species of Al(III) hydrolysis showed different result. During the rapid mixing period, for high coagulant dose, Al-ferron reaction increases rapidly. The kinetic constants, Ka and Kb, derived from Al-ferron reaction. The kinetic constants followed very well the defined tendencies for coagulation condition. For pure water, when the rapid mixing time increased, the kinetic constants, Ka and Kb showed lower values. Also, for raw water, when the rapid mixing time increased, the kinetic constants, Ka and Kb showed lower values.