• Title/Summary/Keyword: 응력회복

Search Result 177, Processing Time 0.031 seconds

Hair Strengthening Effect of Silane Coupling and Carbodiimide Chemistry (카르보디이미드 반응과 실란 커플링을 이용한 모발강화 효과)

  • Son, Seong Kil;Choi, Wonkyung;Lim, Byung Tack;Song, Sang-hun;Kang, Nae Kyu
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.44 no.2
    • /
    • pp.133-139
    • /
    • 2018
  • Chemically damaged hair is vulnerable to external stimuli in daily life due to the weakened physical properties of the hair strand itself. The purpose of this work was to determine whether chemical conjugation between hair keratin proteins restores tensile strength and thus results inpreventing further deterioration under repeated combing. A model damaged hair tress was produced by a typical perm-process. Then, it was internally crosslinked by the bifunctional crosslinker (3-aminopropyl)triethoxysilane (APTES), via both silane coupling and carbodiimide chemistry. Physical properties, including tensile strength, Young's modulus, and plateau stress, were measured to verify the effect of internal crosslinking, and the existence of crosslinking was verified by Fourier transform infrared (FT-IR) spectroscopy. The degrees of hair breakage and split ends were evaluated by repeated combing-drying tests. Physical properties of chemically damaged hair were restored by internal crosslinking. Successful crosslinking of APTES via both silane coupling and carbodiimide chemistry was verified by FT-IR spectra. Prevention of breakage and split ends after repeated combing with heat was observed. Human hair can be weakened by chemical damage including perm-processing, so restoring such properties is a major issue in the hair care industry. This work shows that internal crosslinking of damaged hair via chemical conjugation would be a potent method to restore the healthy hair.

Characteristic Analysis of Permanent Deformation in Railway Track Soil Subgrade Using Cyclic Triaxial Compression Tests (국내 철도 노반 흙재료의 반복재하에 따른 영구변형 발생 특성 및 상관성 분석)

  • Park, Jae Beom;Choi, Chan Yong;Kim, Dae Sung;Cho, Ho Jin;Lim, Yu Jin
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.64-75
    • /
    • 2017
  • The role of a track subgrade is to provide bearing capacity and distribute load transferred to lower foundation soils. Track subgrade soils are usually compacted by heavy mechanical machines in the field, such that sometimes they are attributed to progressive residual settlement during the service after construction completion of the railway track. The progressive residual settlement generated in the upper part of a track subgrade is mostly non-recoverable plastic deformation, which causes unstable conditions such as track irregularity. Nonetheless, up to now no design code for allowable residual settlement of subgrade in a railway trackbed has been proposed based on mechanical testing, such as repetitive triaxial testing. At this time, to check the DOC or stiffness of the soil, field test criteria for compacted track subgrade are composed of data from RPBT and field compaction testing. However, the field test criteria do not provide critical design values obtained from mechanical test results that can offer correct information about allowable permanent deformation. In this study, a test procedure is proposed for permanent deformation of compacted subgrade soil that is used usually in railway trackbed in the laboratory using repetitive triaxial testing. To develop the test procedure, an FEA was performed to obtain the shear stress ratio (${\tau}/{\tau}_f$) and the confining stress (${\sigma}_3$) on the top of the subgrade. Comprehensive repetitive triaxial tests were performed using the proposed test procedure on several field subgrade soils obtained in construction sites of railway trackbeds. A permanent deformation model was proposed using the test results for the railway track.

Finite Element Analysis of Stress Distribution in using Face Mask according to Traction Point (훼이스 마스크의 견인위치에 따른 응력분포에 관한 유한요소법적 연구)

  • Oh, Kyo-chang;Cha, Kyung-Suk;Chung, Dong-hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.171-181
    • /
    • 2009
  • The objective of this study was to analyse stress distribution of maxillary complex by use of face mask. The construction of the three-dimensional FEM model was based on the computed tomography(CT) scans of 13.5 years-old male subject. The CT image were digitized and converted to the finite element model by using the mimics program, with PATRAN. An anteriorly directed force of 500g was applied at the first premolar 45 degrees downwards to the FH plane and at the first molar 20 degrees downwards to the FH plane. When 45 degrees force was applied at maxillary first premolar, there were observed expansion at molar part and constriction at premolar part. The largest displacement was 0.00011mm in the x-axis. In the y-axis, anterior displacement observed generally 0.00030mm at maximum. In the z-axis, maxillary complex was displaced 0.00036 mm forward and downward. When 20 degrees force was applied at maxilla first molar, there were observed expansion at lateral nasal wall and constriction at molar part. The largest displacement was 0.001mm in the X-axis. In the Y-axis, anterior displacement observed generally 0.004mm at maximum. In the Z-axis, ANS was displaced upward and pterygoid complex was displaced downward. The largest displacement was 0.002mm.

Effect of Electropolishing on Surface Quality of Stamped Leadframe (Stamped Leadframe의 표면 품질에 미치는 전해연마 효과)

  • 남형곤;박진구
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.3
    • /
    • pp.45-54
    • /
    • 2000
  • The effect of electropolishing far stamped leadframe on the removal of the edge burr and residual stress relief was examined. The present study showed that the electropolishing could be used for enhanced surface quality of stamped leadframes. The electropolishing was performed at the condition of 60% phosphoric acid electrolyte, 5 ampere of current and 3 cm electrode gap at $70^{\circ}C$ for 2 minutes for Alloy42 type leadframe, and $50^{\circ}C$ for 1.5 minutes for C-194 type leadframe. The FWHM values from X-ray diffraction showed that residual stress of electropolished leadframe recovered to the level of as-received raw materials and surface roughness measured by using AFM tuned out to be improved by 0.079 $\mu\textrm{m}$ and 0.014 $\mu\textrm{m}$ ($R_{rms}$) far alloy 42 and C-194 type leadframes, respectively. The plated thickness using XRF showed the improved uniformity in thickness variation by 0.4~0.5 $\mu\textrm{m}$ and grain growth, which is favorable for interface adhesion, was also observed from the bake test samples. We could certify dimensional stability of leadframe with inspection by means of 3D-topography and hardness measurements.

  • PDF

Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening (지대주 나사 풀림 방지를 위한 새로운 Lock Screw 시스템의 효과에 대한 유한요소해석적 연구)

  • Im, Eun Sub;Kim, Jong Eun;Kim, Jee Hwan;Park, Young Bum
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.3
    • /
    • pp.132-142
    • /
    • 2019
  • Purpose: The purpose of this finite element analysis study is to introduce the novel Lock screw system and analyze its mechanical property to see if it can prevent abutment screw loosening. Materials and Methods: The Lock screw is a component tightened on the inside of the implant abutment which applies compressive force to the abutment screw head. To investigate the effect, modeling was done using CAD program and it was analyzed by finite element analysis under various load conditions. First, the preload was measured according to the tightening torque of the abutment screw then it was compared with the theoretical value to verify the analytical model. The validated analytical model was then divided into those with no external load and those with 178 N, and the tightening torque of the lock screw was changed to 10, 20, 30 Ncm respectively to examine the property of stress distribution on the implant components. Results: Using Lock screw under various loading conditions did not produce equivalent stresses beyond the yield strength of the implant components. In addition, the axial load was increased at the abutment-abutment screw interface. Conclusion: The use of Lock screw does not exert excessive stress on the implant components and may increase the frictional force between the abutment-abutment screw interface, thus it is considered to prevent loosening of the abutment screw.

Microsturcture Control and Compression Characteristics at Room and High Temperature for$\gamma$-TiAI Intermetallic Compounds with Addition Elements (제 3원소가 첨가된 금속간 화합물$\gamma$-TiAI의 미세조직 제어와 상온 및 고온 압축 특성)

  • Jeong, Jin-Seong;Lee, Dong-Hui
    • Korean Journal of Materials Research
    • /
    • v.6 no.1
    • /
    • pp.67-78
    • /
    • 1996
  • 제 3원소가 첨가된 금속간 화합물 TiAI 금속간 화합물 분말을 PREP법(플라즈마 회전전극법)으로 제조하여, 통.방전 강압소결법에 의해 치밀한 소결체를 만들었다. 이에 대해 첨가 원소의 종류와 열처리에 따른 고온 및 상온 압축 특성의 변화를 조사하였다. 소결체의 미세조직은 ${\gamma}$/$\alpha$2 lamella로 이루어진 완전 변태구조였고, 결정립의 크기는 140-150$\mu\textrm{m}$였으며 계단형 결정립계를 나타내었다. 소결체를 ($\alpha$+${\gamma}$)구역인 130$0^{\circ}C$에서 2시간 동안 열처리한 결과, 모든 조성의 시편이 등축점 ${\gamma}$와 lamella로 이루어진 전형적인 duplexrn조로 변태하였다. 상온 압축 시험에서 시편은 파괴될 때까지 가공경화 현상이 나타났으며, Cr을 첨가한 시편이 가장 큰 파괴응력과 변형률을 나타내었다. 한편, 고온 압축 시험의 경우 온도상승 때문에 가공경화의 속도가 감소되었고, 80$0^{\circ}C$에서는 가공경화와 회복이 균형을 이루는 소위 정상 상태의 변형을 보였다.

  • PDF

Prediction of Plastic Settlement of Roadbed Materials through Cyclic Loading Test (반복하중에 따른 철도 노반재료의 소성침하예측)

  • Choi, Chan-Yong;Shin, Eun-Chul;Kang, Hyoun-Hoi
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.3
    • /
    • pp.1-9
    • /
    • 2012
  • If the railways consisting of soil subgrade is applied to repetitive loading, elastic deformation and plastic deformation will occur at the same time. So the repeat traffic loading condition should be considered to predict the long-term deformation on railway roadbed. In this study, laboratory data from the repeated load triaxial tests and cylinder model test were used to predict accumulated settlement on railway foundation and results were analyed based on the nonliear models and stress state considered. It has proposed predict model using power function model on plastic settlement of roadbed materials.

Finite Element Stress Analysis of Implant Prosthesis According to Friction Fit or Slip Fit of Internal Connection System between Implant and Abutment (임플랜트와 지대주 간 내측연결 시스템에서 Friction Fit와 Slip Fit에 따른 유한요소 응력분석)

  • Jang, Doo-Ik;Jeong, Seung-Mi;Chung, Chae-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.21 no.2
    • /
    • pp.113-132
    • /
    • 2005
  • The purpose of this study was to assess the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to a friction-fit joint (Astra; Model 1) or slip- fit joint (Frialit-2; Model 2) in the internal connection system under vertical and inclined loading using finite element analysis. In conclusion, in the internal connection system of the implant and the abutment connection methods, the stress-induced pattern at the supporting bone, the implant fixture, the abutment and the abutment screw according to the abutment connection form had difference among them, and the stress distribution pattern usually had a widely distributed tendency along the inner surface of the implant fixture contacting the abutment post. The magnitude of the stress distributed in the supporting bone, the implant fixture, the abutment and the abutment screw was higher in the friction-fit joint than in the slip-fit joint. But it is considered that the further study is necessary about how this difference in the magnitude of the stress have an effect on the practical clinic.

The FEM Analysis on the Crestal Cortical Bone around the Implant according to the Cancellous Bone Density and Loading Positions (임프란트 매식시 해면골질의 차이에 따른 치밀골 상 응력분석)

  • Jeung, Sin-Young;Kim, Chang-Hyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.1
    • /
    • pp.69-78
    • /
    • 2007
  • This study was performed to compare the stress distribution pattern in the crestal cortical bone and cancellous bone using 3-dimensional finite element stress analysis when 2 different Young's modulus(high modulus, model 1; low modulus, model 2) of cancellous bone was assumed. For the analysis, a finite element model was designed to have two square-threaded implants fused together and located at first and second molar area. Stress distribution was observed when vertical load of 200N was applied at several points on the occlusal surfaces of the implants, including central fossa, points 1.5mm, 2mm, 3mm and 3.5mm buccally away from central fossa. The results were as follows; 1. In both model, the maximum Von-Mises stress in the crestal cortical bone was greater when the load was applied at the central point, points 1.5mm and 2mm buccally away from central fossa than other cases. 2. In the cortical bone around first and second molar, model 2 showed greater Von-Mises stress than model 1. It is concluded that when the occlusal contact is afforded, the distribution of stress varies depending on the density of cancellous bone and the location of loading. More favorable stress distribution is expected when the contact load is applied within the diameter of fixtures.

Flow Measurements at the Exit of a Throttle Valve in Gasoline Engines (가솔린 엔진의 스로틀 밸브 출구에서 유동측정)

  • Kim, Sung-Cho;Kim, Cheol;Choi, Jong-Geon;Wee, Hwa-Bok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.2
    • /
    • pp.1-8
    • /
    • 2002
  • The flow and combustion patterns have been investigated inside the gasoline engine cylinder with the swirl or tumble flow, whereas the air flow characteristics, which are generated in the part of intake system before entering into the intake manifold, have not been known completely. It is necessary to analyze the flow field in the intake system consisting of air rater, throttle valve and intake manifold. The throttle valve, used to control the intake air flow rate, is important because it makes various mass flow rate and flow patterns. Three-dimen-sional How characteristics such as velocities, turbulent intensities and Reynolds shear stresses are measured by the hot wire anemometer at the exit of the throttle valve with the variation in the valve opening angle($15^{\circ}$, $45^{\circ}$, $75^{\circ}$ and $90^{\circ}$) and the Reynolds numbers (45000, 70000 and 140000). There are a lot of changes in flow characteristics at $75^{\circ}$ due to the large recirculation flow comparing with those of the other cases, and the streamwise velocity is especially enforced strongly below the valve shaft. The other component velocities are relatively large near the centerline parallel to the valve shaft. The effects of the Reynolds number on the flow field are not severe.