• Title/Summary/Keyword: 응력오차크기

Search Result 36, Processing Time 0.023 seconds

AJM을 이용한 HDM에 의한 잔류응력 계측에 관한 연구 2

  • 최병길;박영조;이택순;전상윤
    • Journal of Welding and Joining
    • /
    • v.8 no.4
    • /
    • pp.76-82
    • /
    • 1990
  • Lots of research works have been done to improve the accuracy of the hole drilling method to measure residual stress by many investigators. In this study, first, size effect of specimen was analyzed based on the solution of hole in a strip under tension. If the ratio of hole diameter tothe strip width is less than 0.2, the stress distribution around hold may be given from the solution of hole in an infinite plate. Second, the residual stress above $0.6{\sigma}_y$(yield stress) may be measured less than the actual stress by 10-15 percent. Third, eccentricity of hole relative to the rosette center effects on the accuracy of residual stress measurements by 10 percent. The error due to eccentricity of hole can be corrected by the iteration method or the direct method.

  • PDF

Finite Element Analysis of Flow by Adaptive Meshing Technique (적응적 요소망을 이용한 흐름의 유한요소 해석)

  • Jang, Hyung-Sang;Kim, Eu-Gene;Goh, Tae-Jin;Kim, Do-Hun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1721-1725
    • /
    • 2006
  • 유한요소법으로 공학적 문제를 해결할 때에는 적절한 모델링을 통하여 가장 빠르고 정확한 해를 얻도록 해야 한다. 유체 흐름의 기본 변수인 속도는 그 공간 도함수가 요소간에 불연속을 이루게 된다. 속도의 공간 도함수는 기본적으로 유체에서의 응력, 압력, 및 와도 등과 밀접한 관련이 있다. 또한 이러한 요소간의 속도의 공간 도함수에서 발생하는 불연속의 크기는 요소망이 세분화되어 감에 따라 감소하면서 정확한 해에 수렴하게 된다. 즉 속도의 공간 도함수를 대상으로 오차에 정도를 판단하는 것이 기존의 유한요소 모델의 타당성을 판단하는 기준으로 적합함을 알 수 있다.

  • PDF

A Study on the Similitude of Precast Concrete Panel Structure Using one-third Scale Subassemblage Model (1/3 축적 모형실험에 의한 프리캐스트 콘크리트 판구조의 상사성에 관한 연구)

  • 윤재진
    • Magazine of the Korea Concrete Institute
    • /
    • v.4 no.3
    • /
    • pp.123-134
    • /
    • 1992
  • 본연구는 실물크기의 프리캐스트 콘크리트 판구조물의 부분구조체를 모형화하여 실험한 결과를 분석한 것이다. 구조물의 역학적 특성과 파괴성상을 파악하기 위한 구조실험은 실물크기의 구조물과 부재로써 실시하는 것이 가장 좋은 방법이지만, 이것은 치수가 크므로 공간적으로 제한을 받고 많은 시간과 비용을 필요로 하기 때문에 모형실험을 이용하게 된다. 이러한 모형실험을 최소한의 오차범위내에서 원형실험과 같은 재현하고 예측하도록 실험을 준비하는 데에는 상사법칙이 필요하게 된다. 모형은 무엇보다도 원형과의 응력-변형도 관계 등 구성재료에 대한 상사요구조건을 만족시키는 것이 중요하지만, 본 연구의 대상은 1/3축척으로써 기하학적인 요소와 사용재료에 대한 강도의 상사성만을 고려한 모형이다. 본 연구에서는 이러한 모형구조물의 거동을 원형실험결과와 비교하여 상사성 확보의 문제와 가능성을 조사하였다.

Tapered Joint Design for Power Transmission of MW-grade Wind Turbine (MW급 풍력발전기 동력전달용 테이퍼 연결장치 설계에 관한 연구)

  • Kang, JongHun;Bae, JunWoo;On, Hanyong;Kwon, Yongchul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1183-1189
    • /
    • 2015
  • This study focuses on the design of the tapered joints of a wind power turbine. The main variables of the tapered joint are the transmitted torque, shaft diameter, contact area of the tapered ring, and tightening torque of the bolts, which applies a compressive pressure from the hub to the shaft. The stress distribution of the taper fit was calculated under axisymmetric plane strain conditions because of the small taper angle. The axial displacement of the clamp can be calculated from the radial elastic deformation and the taper angle. The stress field of each ring is obtained from the cylinder stress equation. To verify the accuracy of the calculation, finite element (FE) analysis was performed, and the results of the calculation and FE analysis were compared. The hoop stress of the tapered surface showed a discrepancy of approximately 10, but the trends of the stress distributions of each component and the relative movement obtained by FE analysis were in good agreement with the analytical calculation results.

Conductive Performance of Mortar Containing Fe-Activated Biochar (Fe에 의해 활성화된 목질계 바이오차를 혼입한 모르타르의 전도성능)

  • Jin-Seok Woo;Ai-Hua Jin;Won-Chang Choi;Soo-Yeon Seo;Hyun-Do Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.2
    • /
    • pp.27-34
    • /
    • 2024
  • This study was conducted to examine the feasibility of using Fe-activated wood-derived biochar as a conductive filler for manufacturing cement-based strain sensor. To evaluate the compressive and electrical properties of cement composite with 3% Fe-activated biochar, three cubic specimens of size 50 x 50 x 50mm3 and three prismatic cement-based sensors of size 40 x 40 x 80mm3 were prepared respectively. The four-probe method of electrical resistance measurement was used for cement-based sensors. For cement-based sensors with FE-activated biochar, the conductive performance such as electrical resistance and impedance under different water content and repeated compression was investigated. Results showed that the fractional changes in the DC electrical resistivity of cement-based sensors increase with increasing time and the maximum fractional changes in the resistivity decrease with increasing the moisture contents during 900s. At moisture content of 7.5% range, the conductive performance of cement composite including 3% Fe-activated biochar as a conductive filler showed the most stable, while the strain detection ability tended to decrease somewhat as the repeated compressive stress increased between repeated compressive strain and fractional change in resistivity (FCR).

Transfinite Interpolation Technique for P-Version of F.E.M. (초유한 보간법에 의한 p-version 유한요소해법)

  • 우광성
    • Computational Structural Engineering
    • /
    • v.5 no.1
    • /
    • pp.75-82
    • /
    • 1992
  • In the h-version of F.E.M., all piecewisely smooth curved boundaries can be approximated by a sufficient number of straight-sided elements. However, in the p-version the size of the element is usually large and hence the probability of distortions is more. An attempt has been made to generate a curved boundary by using a transfinite interpolation technique to avoid the discretization errors. In the following sections, it will be shown how to construct transfinite interpolants both in h-version and in p-version over polygonal and nonpolygonal regions. Three numerical tests are shown to validate the applicability and superior capability of transfinite interpolation technique.

  • PDF

Material Nonlinear Finite Element Analysis of Reinforced Concrete Structures (재료비선형성을 고려한 R/C 구조물의 유한요소해석)

  • Choi, Chang Koon;Kwak, Hyo Gyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.9 no.3
    • /
    • pp.31-38
    • /
    • 1989
  • This paper concentrates on the analysis of reinforced concrete(R/C) structures subjected to monotonic loading, from zero to ultimate loads. Tensile cracking, the nonlinear stress-strain relationship for concrete and reinforcement are taken into account the concrete is assumed to be elastic in tension region and elasto-hardening plastic in compression region. The Kupfer's failure criteria and associated flow rule are adopted to govern the plastic behavior of the concrete. The reinforcing bar is considered as a elasto-hardening platic material. The tension stiffening effect of the concrete between cracks is also considered. The numerical error depends on the used finite element mesh size is reduced by correcting the slope of strain softening region of the concrete according to the developed energy criteria.

  • PDF

Numerical Study on Vertical Stress Estimation for Panel Pillars at Room and Pillar Mines (주방식 광산의 패널 광주 수직응력 추정을 위한 수치해석 연구)

  • Yoon, Dong-Ho;Song, Jae-Joon
    • Tunnel and Underground Space
    • /
    • v.30 no.5
    • /
    • pp.473-483
    • /
    • 2020
  • This paper examines the vertical stress change concentrated on mine pillar which occurs due to the stress disturbance from opening excavation at room and pillar mine by FLAC3D, a finite difference method (FDM) software. The mesh size combination is decided with a careful consideration of relative error and run-time, then its performance is verified. A series of numerical analyses is conducted and the vertical stress at central pillar was observed for the test cases of 1×1 to 11×11 mine pillars, 40 m to 320 m depth with 40 m difference. The results show that the vertical stress of pillar approaches to the similar value with the value estimated by tributary area theory(TAT) when the development area (NP) is increased or the height of overburden (HOB) is decreased, while it is overestimated in the opposite case. Furthermore, it also represents that the vertical stress factor (VSF) converges to a specific value when the depth is increased whille keeping the development area identical.

Adaptive Mesh Generation in Large Deformation Analysis of Shell Structures with Advancing Front Method (Advancing Front Method를 이용한 대변형 쉘 구조물의 적응적 유한요소 자동생성법)

  • 장창두;정진우;문성춘
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.3
    • /
    • pp.447-455
    • /
    • 1999
  • An adaptive mesh generation scheme is developed for effective non-linear analysis of the shell structures under large deformation. In particular, based on a posteriori error estimation, remeshing method on each load step is of primary interest here. An advancing front method, called paving method, is adopted for remeshing. It can be known that the adaptive mesh generation using contours of spacing values obtained from stress errors has an advantage in the adaptive analysis of the shell structures.

  • PDF

A Study on Fatigue Crack at Coped Stringers of the Plate Girder Subway-Bridge (플레이트거더 지하철교량 세로보의 피로 균열에 관한 연구)

  • Jo, Jae Byung
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.5 s.72
    • /
    • pp.713-724
    • /
    • 2004
  • A fatigue crack found at the coped stringer of the old dismantled Dangsan Subway Bridge was numerically simulated. A model of a single span of the plate girder bridge with its beam elements was created and analyzed in order to obtain the nominal stress history caused by trains. A detailed FEM analysis of the coped stringer was conducted using a shell element model. A fracture mechanical model was used to estimate crack propagation. The stress intensity factors were calculated using the J-Integral method. The simulation with some reasonable assumptions showed that the calculated crack lengths were comparable to those found on the site.