• Title/Summary/Keyword: 음향인텐시티

Search Result 84, Processing Time 0.026 seconds

Vibration Intensity Analysis of Penetration Beam-plate Coupled Structures (관통보와 평판의 연결 구조물에 대한 진동인텐시티 해석)

  • 홍석윤;강연식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.73-81
    • /
    • 2002
  • The transmission of vibration energy through beam-plate junctions in vibration intensity analysis called power new analysis (PFA) has been studied. PFA is an analytic tool for the prediction of frequency averaged vibration response of built-up structures at medium to high frequency ranges. The power transmission and reflection coefficients between the semi-infinite beam and plate are estimated using the wave transmission approach. For the application of the power coefficients to practical complex structures, the numerical methods, such as finite element method are needed to be adapted to the power flow governing equation. To solve the discontinuity of energy density at the joint, joint matrix is developed using energy flow coupling relationships at the beam-plate joint. Using the joint matrix developed in this paper, an idealized ship stem part is modeled with finite element program, and vibration energy density and intensity are calculated.

Analysis of Sound Attenuation by Chambers in Duct Systems by the Finite Element Method (유한요소법에 의한 소음기의 감음특성해석)

  • 최석주
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.23-27
    • /
    • 1991
  • 각종 홀 (음악홀, 극장, 사무실건물)의 공조 덕트계에는 미로형소음챔버가 설 치되는 경우가 많다. 이러한 소음장치를 건물내부에 설치하는 경우에는 건물 설계단계에서부터 소음챔버로 인한 감음양(투과손실 : Transmission Loss)의 예측계산이 중요하다. 그렇지만, 일반적인 소음장치는 그 형상이나 내표면의 흡음조건이 아주 복잡하기 때문에, 현단계에서는 간단한 이론만으로 투과손 실예측이 거의 불가능하다. 지금까지 이 문제에 대해서 유한요소법(Finite Element Method : FEM)을 이용해 검토한 예가 종종 소개되었으나, 대부분 소음챔버의 입구와 출구에서의 임의의 점에 대한 음압비를 투과손실로서 구 하고 있다. 그러나, 소음기자체의 실질적인 투과손실특성을 알기 위해서는 소음기의 입력 파워에 대한 출력파워의 비로서 구하지 않으면 안된다. 따라 서, 본 연구에서는 유한요소법에 의한 복소음향인텐시티(Complex sound intensity)의 수치계산법을 각종소음기 (팽창형, 미로형)의 투과손실해석에 적 용하기 위하여 이론적인 면에서 고찰했으며, 프로그램도 개발하여 모델해석 에 적용하였다. 또한, 위에서 언급된 수치해석법의 타당성의 검증을 위하여, 측정에 의한 투과손실예측방법으로서 크로스스펙트럼(Cross Spectrum)법에 의한 음향인텐시티계측법의 이용에 대해서 이론적으로 고찰했으며, 그 이론 을 기초로 한 축척 모형실험을 병행하였다.

  • PDF

Prediction of Interior Noise Caused by Tire Based on Sound Intensity and Acoustic Source Quantification (공기 기인 소음 분석과 음향 인텐시티법을 이용한 타이어에 의한 실내 소음 예측)

  • Shin, Kwang-Soo;Lee, Sang-Kwon;Hwang, Sung-Uk
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.4
    • /
    • pp.315-323
    • /
    • 2013
  • Tire noise is divided into a road noise(structure-borne noise) and a pattern noise(air-borne noise). Whilst the road noise is caused by the structural vibration of the components on the transfer path from tire to car body, the pattern noise is generated by the air-pumping between tire and road. In this paper, a practical method to estimate the pattern noise inside a passenger car is proposed. The method is developed based on the sound intensity and airborne source quantification. Sound intensity is used for identifying the noise sources of tire. Airborne source quantification is used for estimating the sound pressure level generated by each noise source of a tire. In order to apply the airborne source quantification to the estimation of the sound pressure, the volume velocity of each source should be obtained. It is obtained by using metrics inverse method. The proposed method is successfully applied to the evaluation of the interior noises generated by four types of tires with different pattern each other.

A method to generate virtual intensity at arbitrary position: Methodology and its physical meanings (임의의 위치에 가상 인텐시티 형성 방법: 방법론과 그 물리적 의미)

  • 최정우;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.652-657
    • /
    • 2003
  • This paper proposes a method to generate virtual intensity field in space. The sound field of a zone enclosing the listener position is controlled to have maximum acoustic intensity to the desired direction. In order to control acoustic intensity of a zone, space-averaged active intensity is introduced. The ratio of space-averaged active intensity and control effort is defined as a cost function and expressed as a function of source control signals. It is shown that the cost function represents radiation efficiency of multiple sources. The control signals maximizing the cost function is found through eigenvalue analysis. The proposed method is verified by numerical simulations performed in free field condition, and the results provide a relation between wavelength and the size of controllable intensity field.

  • PDF

A study on the identification of dynamic characteristics of tennis racket by acoustic intensity method (음향 인텐시터법을 이용한 테니스 라켓의 동특성에 관한 연구)

  • 오재응;이유엽;염성하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.601-610
    • /
    • 1986
  • The acoustic intensity in the very near field of a vibrating surface reveals information about the location of sound sources and sinks. A system model of tennis racket was developed from simultaneous measurement of excitation force, surface vibration and the near field sound pressure. The characteristics of structural dynamics were obtained by standard experimental modal analysis techniques while the sound radiation characteristics were determined by estimating the acoustic intensity. In this paper, the information about vibration behviour was obtained by acoustic intensity method and some, experiments for verification were carried out. Close correlation was found between experimentally determined acoustic intensity and vibration mode patterns of the tennis racket.

Sound Insulation Strategy for the Tunnel Noise in a High Speed Train (고속철도차량의 터널 소음을 위한 차음 전략)

  • Kim, Seock-Hyun;Lee, Ho-Jin;Kim, Jung-Tae
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.4
    • /
    • pp.315-322
    • /
    • 2012
  • In a tunnel, interior noise of a high speed train increases by 5dB~7dB. The reason is that the sound intensity of the acoustic field in the tunnel significantly increases by the reflected waves occurred in the closed space. Especially, the incident acoustic power largely increases on the outside of the compartment side panel and large transmission of noise is available through the side panel and the glass window. In this paper, the sound insulation strategy in the tunnel is proposed for the next generation high speed train under development. Specimens of the aluminum extruded panels, layered panels and double glazed window are manufactured and intensity transmission loss is measured according to ASTM E2249-02. Based on the measured data, problems in the sound insulation performance are diagnosed and the sound insulation strategy is reviewed on each panel and layered structures.

Study on sound radiation estimation using a reciprocity technique and p-p method by finite element simulation (상반성 기법과 p-p method를 이용한 구조물 방사소음 유한요소해석 기법 연구)

  • Ji Woo Yoo;Hun Park;Ji Un Lee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.1
    • /
    • pp.1-6
    • /
    • 2023
  • Sound radiated from a structure in vibration is an important physical characteristic to evaluate vibro-acoustic problem. Although sound radiation power can be typically obtained by intensity measurement, long measuring time and strict measuring condition remain difficult. As an alternative method, simulation-based estimation can be taken into account and its accuracy is known to be acceptable. However, difficulty still lies in that specialized softwares may be necessary to obtain sound radiation power and radiation efficiency. In this context, this study suggests two methods using an ordinary FE method to calculate sound radiation power. They are well-known reciprocity technique and p-p method, which are basically test methods. It is shown that either method can practically estimate sound radiation in the frame of conventional Finite Element Method (FEM). The methods and their corresponding limit are discussed with some results.

The Noise Radiation Characteristics of Axial Fan by Experimental Method (실험적 방법에 의한 축류형 팬의 소음 방사 특성에 관한 연구)

  • 김동규;오재응
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.1E
    • /
    • pp.50-55
    • /
    • 1992
  • 팬의 익면 통과 주파수 소음은 총괄 소음 스펙트럼중에서 가장 명백한 성분이다. 그 소리는 일 반적으로 가장 불쾌한 성분이므로 저감이 요구된다. 따라서 그 소음치를 저감시키기 위해서는 정확한 축류형 팬의 소음원과 소음 방사 특성 규명이 요구된다. 본 연구에서는 푹류형 팬의 소음원과 소음 방 사 특성을 정의하였다. 음압 및 음향인텐시티를 이용한 음원 해석에서, 광센서를 이용한 축류형 팬의 동 기화가 수행되었고, 팬 날개에서의정확한 소음원의 위치를 결정하기 위해 Recording time의 결정이 제 안되었다. 팬 회전시, 소음원의 위치는 각 날개의 후단과 그 다음 날개의 선단사이에 각각 존재한다. 지 향성을 통하여 축류형 팬의 소음 방사 형태를 결정하였고, 벡터 에너지 흐름도로 음의 흐름을 가시화하 였다. 팬 익면에서의 회전 진동특성을 스트레인 게이지에 의하여 규명하였고, 또한 구조진동음의 음으로 의 기여도를 측정하였다. 또한 압전필름에 의한 팬 익면에서의 정압측정 가능성이 제시되었다.

  • PDF

A Method to Manipulate Sound Power within a Selected Region Using Source Array (스피커 어레이를 사용한 공간의 음향 파워 제어 방법)

  • 최정우;김양한
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.278-281
    • /
    • 2004
  • Multiple sound sources are controlled to enhance sound power within a zone of interest. The problem of enhancing acoustic variable can be regarded as an optimization problem, which seeks an optimal control input that maximizes the acoustic variable. It should be noted that enhancing sound power of a selected region requires both the magnitude and direction to be controlled. For this reason, two kinds of cost functions that can represent the spatially distributed intensity are defined. Theoretical formulation shows the possibility of sound power control in a zone, and the detailed procedures of the proposed method are validated by numerical simulations.

  • PDF

Application of Sound Intensity Camera for the Noise Source Analysis (소음원 규명을 위한 음향 인텐시티 카메라 응용)

  • Lee, Chang-Myung;Bae, Young-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.229-230
    • /
    • 2009
  • A method is suggested for the noise source identification using the sound intensity method. The suggested method does not need to install the grid using wire or thread during the sound intensity measurement for the noise source identification. It utilizes a camera to show the grid on the screen not installing the real grid for the sound intensity method.

  • PDF