• Title/Summary/Keyword: 음향미세유체역학

Search Result 4, Processing Time 0.018 seconds

On-demand Acoustofluidic Droplet Generation with Tunable Droplet Volume (음향미세유체역학적 미세액적 생성 및 부피 제어)

  • Kim, Woo Hyuk;Park, Jinsoo
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.2
    • /
    • pp.46-50
    • /
    • 2020
  • On-demand droplet generation with tunable droplet volume is fundamental in many droplet microfluidic applications. In this work, we propose an acoustofluidic method to produce water-in-oil droplets with prescribed volume in an on-demand manner. Surface acoustic waves produced from a slanted interdigital transducer are coupled with parallel laminar streams of dispersed and continuous phase fluids. Acoustic radiation force acting on the fluid interface enable generation of droplets in a microfluidic chip. We expect that the proposed acoustofluidic droplet generation method will serve as a promising tool for on-demand droplet generation with on-chip droplet volume control.

Size-based separation of microscale droplets by surface acoustic wave-induced acoustic radiation force (표면파 유도 음향방사력을 이용한 미세액적의 크기 선별)

  • Mushtaq, Ali;Beomseok, Cha;Muhammad, Soban Khan;Hyunwoo, Jeon;Song Ha, Lee;Woohyuk, Kim;Jeongu, Ko;Jinsoo, Park
    • Journal of the Korean Society of Visualization
    • /
    • v.20 no.3
    • /
    • pp.19-26
    • /
    • 2022
  • In droplet microfluidics, precise droplet manipulation is required in numerous applications. This study presents ultrasonic surface acoustic wave (USAW)-based microfluidic device for label-free droplet separation based on size. The proposed device is composed of a slanted-finger interdigital transducer on a piezoelectric substrate and a polydimethylsiloxane microchannel placed on the substrate. The microchannel is aligned in the cross-type configuration where the USAWs propagate in a perpendicular direction to the flow in the microchannel. When droplets are exposed to an acoustic field, they experience the USAW-induced acoustic radiation force (ARF), whose magnitude varies depending on the droplet size. We modeled the USAW-induced ARF based on ray acoustics and conducted a series of experiments to separate different-sized droplets. We found that the experimental results were in good agreement with the theoretical estimation. We believe that the proposed method will serve as a promising tool for size-based droplet separation in a label-free manner.

Size-based Separation of Yeast Cell by Surface Acoustic Wave-induced Acoustic Radiation Force (음향방사력을 이용한 효모세포의 크기별 분리)

  • Raihan Hadi Julio;Muhammad Soban Khan;Mushtaq Ali;Ghulam Destgeer;Jinsoo Park
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.3
    • /
    • pp.93-100
    • /
    • 2023
  • The yeast Saccharomyces cerevisiae (S. cerevisiae) is considered an ideal eukaryotic model and has long been recognized for its pivotal role in numerous industrial production processes. Depending on the cell cycle phases, microenvironment, and species, S. cerevisiae varies in shape and has different sizes of each shape such as singlets, doublets, and clusters. Obtaining high-purity populations of uniformly shaped S. cerevisiae cells is crucial in fundamental biological research and industrial operations. In this study, we propose an acoustofluidic method for separating S. cerevisiae cells based on their size using surface acoustic wave (SAW)-induced acoustic radiation force (ARF). The SAW-induced ARF increased with cell diameter, which enabled a successful size-based separation of S. cerevisiae cells using an acoustofluidics device. We anticipate that the proposed acoustofluidics approach for yeast cell separation will provide new opportunities in industrial applications.

In-droplet preconcentration of microparticles using surface acoustic waves (표면탄성파를 이용한 액적 내 마이크로입자의 농축)

  • Park, Kwangseok;Park, Jinsoo;Jung, Jin Ho;Destgeer, Ghulam;Ahmed, Husnain;Ahmad, Raheel;Sung, Hyung Jin
    • Journal of the Korean Society of Visualization
    • /
    • v.15 no.1
    • /
    • pp.47-52
    • /
    • 2017
  • In droplet-based microfluidic systems, in-droplet preconcentration of a sample is one of the important prerequisites for biochemical or medical analysis. There have been a few studies on preconcentration in a moving droplet, but they are limited to practical applications since 1) their method are time-consuming or 2) they require specific properties such as electric and magnetic properties. In this study, we demonstrated the position control of polystyrene particles of 5 and $10{\mu}m$ in diameter inside a moving water-in-oil droplet using traveling surface acoustic waves. Since the frequencies for effective control of each diameter were found, microparticles with no labels could be utilized. In addition, the proposed method enabled on-demand preconcentration inside a polydimethylsiloxane microchannel. In-droplet preconcentration of microparticles was realized by splitting a mother droplet with manipulated particles at a downstream bifurcation zone. Given these advantages, the proposed system is a promising acoustofluidic lab-on-a-chip platform for preconcentration inside a droplet.