• Title/Summary/Keyword: 음압해석

Search Result 172, Processing Time 0.024 seconds

Investigation of the Lateral Acoustic Signal Detection Using by Two Fabry-Perot Fiber Optic Sensor Array (두 개의 Fabry-Perot 광섬유 센서 배열을 이용한 횡방향 음압 감지 특성 연구)

  • Lee, Jong kil
    • 대한공업교육학회지
    • /
    • v.31 no.1
    • /
    • pp.185-199
    • /
    • 2006
  • In this paper, to detect lateral direction sound pressure fiber optic sensor using Fabry-Perot interferometeric sensor array was fabricated and experimented. This parallel sensor array composed of one light source and the light split into each sensor using directional coupler and to see the output signal the array system do not need any digital signal processor. As a lateral direction sound source arbitrary sound frequency of 100Hz, 200Hz, and 655Hz using by nondirectional speaker were applied to the array sensor which installed on $60cm{\times}60cm{\times}60cm$ latticed structure. The detected signals from the two sensors were analyzed in the time and frequency domains. It was confirmed that the suggested sensor array detected applied sound source well but there were a little amplitude differences in between the sensors. Because the sensor supported simply at both ends theoretical analysis was performed and its solution was suggested. To compare the theoretical and experimental results arbitrary sound frequency of 2kHz was applied to the sensor array. It shows that experimental results was good agreement with theoretical results.

The Research of Ultrasonic Transmitter Technique for Preventing the Scales in Boiler (스케일방지용 초음파발신기기술 연구)

  • Heo Pil Woo;Lee Yang Lae;Lim Eui Su
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.251-256
    • /
    • 1999
  • 보일러등의 관벽에 부착되는 스케일 방지용으로 설계된 초음파 발신기는 전기적 신호를 기계적신호로 변환시켜주는 진동자와 발생된 초음파를 부하매질에 전달하는 도파봉으로 구성된다. 본 논문에서는 진동자로 사용되는 자왜소자의 형상설계와 진동자에서 발생된 초음파를 증폭시켜 부하매질로 전달되기위한 몇가지 형태의 도파봉에 대해 이론해석 및 FEM 해석을 수행하였다. 또한 제작된 초음파 발신기의 성능을 음압측정을 통해 확인하였다.

  • PDF

Vibrations of a Fluid-filled Thick Cylindrical Shel with Embedded Internal Strength Members (길이 방향 내심 장력재를 갖는 유체 충진된 두꺼운 원통 셀의 진동 해석)

  • 함일배;정의봉;이헌곤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.340-343
    • /
    • 1995
  • 본 연구에서는 내심형 장력재가 셀 벽속에 묻혀 있는 경우에, 셀의 진동 및 내부 음압을 셀과 장력부재 그리고 내부 충진유체들의 상호 작용을 고려하여 계산하였다. 계산 결과, 셀 재료와 인장 부재의 탄성계수, 감쇠특성의 차이에 따라 응답이 변화함을 확인할 수 있었으며, 각각의 재료 특성 및 설계 변수들에 대한 추가 연구를 수행하여, 내심형 장력 부재를 갖는 유체 충진 원통형 셀의 진동 전달 특성 해석 및 최적화 설계에 이 연구 결과들을 적용할 수 있을 것으로 판단된다.

  • PDF

Analysis of Sound field in a Reverberation room (잔향실의 음장해석)

  • 권영필;임정빈;이주원;이득웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.124-129
    • /
    • 1996
  • 잔향실의 내부 음장을 해석한 결과 다음과 같은 결론을 얻을 수 있었다. 1) 벽면의 흡음률이 동일한 경우는 음향 임피던스의 실수항과 허수항의 변화, 즉 위상의 변화에 따른 음장의 변화가 없다. 2) 5각 형태의 잔향실은 벽면의 흡음률 변화에 따른 음장의 변화가 없다. 3) 4각 형태의 잔향실은 5각 형태의 잔향실보다는 음장이 불균일하며 벽면의 흡음률이 증가함에 따라 음압레벨이 표준편차가 커진다.

  • PDF

A Study of Interventricular volume Pressure in a Totally Implantable Electromechanical Artificial heart (완전 이식형 전기기계식 인공심장 심실간 공간 압력 파형에 관한 연구)

  • Jo, Yung-Ho;Choi, Won-Woo;Park, Seong-Keun;Lee, Dong-Joon;Choi, Jae-Soon;Kim, Hee-Chan;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.222-226
    • /
    • 1995
  • 인공심장에서의 박출량제어는 전부하에 따른 심박출균형, 심실내 완전충만과 완전구출을 구현하는데 그 목적이 있다. 본 논문에서는 인공심장 내부의 심실간 공간 압력파형을 심박출량의 제어에 활용하였다. 이를 위해서는 심실간 공간의 압력파형을 심실 유입부와 유출부의 혈류량에 대한 정보, 이동작동기의 위치신호와 동기시켜 해석하는 것이 필요하다. 이러한 압력파형의 해석을 바탕으로, 심실간 공간의 음압 크기로 좌,우 심방압을 추정하고 작동기의 좌,우 수축기때 심실간 공간의 음압크기를 비슷하게 유지하도록 작동거리를 제어하면 좌우 심박출 균형을 이룰 수 있음을 확인하였다. 또한, 심실의 완전충만과 완전구출의 실현을 위한 심실 충만 정도를 추정할 수 있게 하는 인자를 제시하였다.

  • PDF

PowerFLOW Simulation of the Hyundai Simple Model for Sunroof Buffeting (HSM의 썬루프 버페팅을 위한 PowerFLOW 해석)

  • Choi, Eui-Sung;Cyr, Stephane
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.3
    • /
    • pp.189-197
    • /
    • 2014
  • A simplified model in the shape of a wedge box with an opening on the roof was used to generate buffeting conditions at HMC. These measurements performed in controlled conditions are intended to validate the ability of CFD tools to predict buffeting. The results obtained by PowerFLOW are presented in this paper for buffeting and for the boundary layer development on the roof of the model when the roof opening is closed. The flow mechanisms that explain the behavior of the experimental sound pressure level(SPL) curve are described, and an improved setup is used to reproduce the flow structures that lead to the measured SPL.

Damping Characterization of the Double-skin Aluminum Extruded Panels for Rolling Stock Carbody (철도차량 차체용 더블 스킨 알루미늄 압출 패널의 감쇠특성)

  • Kang, Gil-Hyun;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3197-3202
    • /
    • 2013
  • When car builder designs the large carbody structure of railway vehicles, it is necessary to optimize the damping characteristics through the analysis of structure borne noise such as sound pressure level(SPL). This paper is a study on the structure borne noise analysis by characterizing the damping of double skin aluminum extruded panels for rolling stock carbody. The normalized SPL was calculated based on the simple source theory using measured mechanical mobility parameters from vibration tests(i.e. point, transfer and modal mobility). The reduced SPL was predicted by using finite element method by applying loss factor of damping material into laminated shell elements. It was found out that the damping material coated on the panels like underframe, which part is seriously affected by vibration during train run, took effect to reduce noise level.

Analysis of the Resonant Characteristics of a Tonpilz Transducer with a Fixed Tail Mass by the Equivalent Circuit Approach (등가회로를 이용한 후면추 고정형 Tonpilz 트랜스듀서의 공진 특성 해석)

  • Kim, Jin-Wook;Kim, Won-Ho;Joh, Chee-Young;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.344-352
    • /
    • 2011
  • In this paper, the resonant characteristic of a Tonpilz transducer with a fixed tail mass has been studied by means of an equivalent circuit approach. An equivalent circuit has been designed to describe the characteristic of a Tonpilz transducer that has an additional resonance because of its fixed tail mass. The transmitting voltage response of the transducer calculated by the designed circuit has been compared with that by the FEA (finite element analysis) to confirm the validity of the circuit. This equivalent circuit approach produces identical results with the FEA, in which the variation of resonant frequencies and TVR has been clearly figured out in relation to the stiffness of the mounting fixture and the mass of the tail mass. The suggested equivalent circuit can be utilized to figure out the characteristics of the Tonpilz transducer more efficiently than FEA that requires much calculation time and revision of the models in accordance with the variation of design variables.

An Analysis of the Sound Propagation between Rooms with Different Mediums (서로 다른 매질을 갖는 격실사이의 음파전달해석)

  • Kim, Hyun-Sil;Kim, Jae-Seung;Lee, Seong-Hyun;Seo, Yun-Ho
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.5
    • /
    • pp.402-407
    • /
    • 2013
  • In this paper, an analysis of sound propagation between two rooms with different mediums is discussed. Statistical energy analysis (SEA) is used to consider energy equilibrium among subsystems associated with the sound pressure levels in two rooms and the vibration level of the wall between rooms. Effect of the sound radiation from the structure-borne noise of the wall on sound pressure level of the receiving room is investigated. For a numerical example, sound propagation between engine room and water tank joined by a steel plate whose size is $8.4{\times}4$ m, is considered. It is found that when the critical frequency of the plate is above the frequency range of interest, the sound pressure level in the water tank is dominated by sound transmission through the plate, while sound radiation from the structure-borne noise of the plate is negligible except low frequency range below 63 Hz.