• Title/Summary/Keyword: 윤곽 테스트

Search Result 18, Processing Time 0.029 seconds

Algorithm of Adaptive Noise Reduction with Modified Sigma Filter for Reduction of Edge Blurring and Minute Noises (윤곽선 훼손 방지 및 미세잡음 제거를 위한 Modified Sigma Filter를 이용한 적응적 잡음 제거장치 알고리즘)

  • Yang, Jeong-Ju;Han, Hag-Yong;Yang, Hoon-Gee;Kang, Bong-Soon;Lee, Gi-Dong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.10
    • /
    • pp.2261-2268
    • /
    • 2010
  • The information captured by imaging devices such as CCD or CIS may contain external noises through the processes of passing signals or storing images. In this paper, we propose a Modified Sigma Filter (MSF) algorithm to reduce such noises. In experiment, we verified that our MSF algorithm showed better performance in PSNR and 1D plot of simulation results compared with Gaussian Filter (GF), Local Sigma Filter (LSF). Tested images include random Gaussian Noises.

A Study on Implementation of the High Speed Feature Extraction System Based on Block Type Classification (블록 유형 분류 알고리즘 기반 고속 특징추출 시스템 구현에 관한 연구)

  • Lee, Juseong;An, Ho-Myoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.3
    • /
    • pp.186-191
    • /
    • 2019
  • In this paper, we propose a implementation approach of the high-speed feature extraction algorithm. The proposed method is based on the block type classification algorithm which reduces the computation time when target macro block is divided to smooth block type that has no image features. It is quantitatively identified that occurs at 29.5% of the total image using 200 standard test images with $64{\times}64$ macro block size. This means that within a standard test image containing various image information, 29.5% can reduce the complexity of the operation. When the proposed approach is applied to the Canny edge detection, the required latency of the edge detection can be completely eliminated, such as 2D derivative filter, gradient magnitude/direction computation, non-maximal suppression, adaptive threshold calculation, hysteresis thresholding. Also, it is expected that operation time of the feature detection can be reduced by applying block type classification algorithm to various feature extraction algorithms in this way.

Vision-based Real-Time Traffic Emission Monitoring System (비전 기반의 실시간 대기오염 모니터링 시스템 개발)

  • Shin, Yunhee;Jung, Jinwoo;Yoo, Daewon;Park, Dongsoo;Kim, Eun Yi;Woo, Jung-Hun;Lim, Sang-Beom;Ju, Jin-Seon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2010.04a
    • /
    • pp.439-442
    • /
    • 2010
  • 본 논문에서는 비전 기반의 실시간 대기오염 모니터링 시스템을 제안한다. 제안된 시스템은 먼저 실시간으로 제공되는 동영상을 분석하여 차종 별 대수와 평균속도 등의 교통 파라미터를 실시간으로 추출하고, 이를 바탕으로 대기 중의 CO, NO2등의 밀도를 추정하여 시간대별 대기 오염도를 모니터링 한다. 이를 위해 제안된 시스템은 배경모델을 이용한 차량 추출, 차종 별 윤곽선 및 크기 정보를 이용하여 템플릿 기반으로 차종을 인식하고 이를 추적하여 대수 및 속도를 인식한다. 제안된 시스템의 평가를 위해 교통이 밀집된 공간에 설치하여 테스트하였고, 실제 결과와 비교한 결과, 차량 속도에서 정확도 83.3%, 차종인식에서 정확도 86.98%를 보였다. 이러한 실험 결과는 제안된 시스템이 다양한 지역에서 실시간 대기오염물질 배출량을 산정하는데 적용될 수 있음을 보여주었다.

Improvement of Edge Detection Using Mean Shift Algorithm (Mean Shift 알고리즘을 활용한 경계선 검출의 향상)

  • Shin, Seong-Yoon;Lee, Chang-Woo;Rhee, Yang-Won
    • Journal of the Korea Society of Computer and Information
    • /
    • v.14 no.6
    • /
    • pp.59-64
    • /
    • 2009
  • Edge detection always influenced by the noise of original image, therefore need some methods to eliminate them in advance, and the Mean Shift algorithm has the smooth function which suit for this purpose, so adopt it to fade out the unimportant information and the sensitive noise portions. Above all, we use the Canny algorithm to pick up the contour of the objects we focus on. And, take tests and get better result than the former sole Canny algorithm. This combination method of Mean Shift algorithm and Canny algorithm is suitable for the edge detection processing.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

Implementation of JBIG2 CODEC with Effective Document Segmentation (문서의 효율적 영역 분할과 JBIG2 CODEC의 구현)

  • 백옥규;김현민;고형화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6A
    • /
    • pp.575-583
    • /
    • 2002
  • JBIG2 is an International Standard fur compression of Bi-level images and documents. JBIG2 supports three encoding modes for high compression according to region features of documents. One of which is generic region coding for bitmap coding. The basic bitmap coder is either MMR or arithmetic coding. Pattern matching coding method is used for text region, and halftone pattern coding is used for halftone region. In this paper, a document is segmented into line-art, halftone and text region for JBIG2 encoding and JBIG2 CODEC is implemented. For efficient region segmentation of documents, region segmentation method using wavelet coefficient is applied with existing boundary extraction technique. In case of facsimile test image(IEEE-167a), there is improvement in compression ratio of about 2% and enhancement of subjective quality. Also, we propose arbitrary shape halftone region coding, which improves subjective quality in talc neighboring text of halftone region.

Multi-modality MEdical Image Registration based on Moment Information and Surface Distance (모멘트 정보와 표면거리 기반 다중 모달리티 의료영상 정합)

  • 최유주;김민정;박지영;윤현주;정명진;홍승봉;김명희
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.31 no.3_4
    • /
    • pp.224-238
    • /
    • 2004
  • Multi-modality image registration is a widely used image processing technique to obtain composite information from two different kinds of image sources. This study proposes an image registration method based on moment information and surface distance, which improves the previous surface-based registration method. The proposed method ensures stable registration results with low registration error without being subject to the initial position and direction of the object. In the preprocessing step, the surface points of the object are extracted, and then moment information is computed based on the surface points. Moment information is matched prior to fine registration based on the surface distance, in order to ensure stable registration results even when the initial positions and directions of the objects are very different. Moreover, surface comer sampling algorithm has been used in extracting representative surface points of the image to overcome the limits of the existed random sampling or systematic sampling methods. The proposed method has been applied to brain MRI(Magnetic Resonance Imaging) and PET(Positron Emission Tomography), and its accuracy and stability were verified through registration error ratio and visual inspection of the 2D/3D registration result images.

A comparative study for resolution and density of chest imaging using film/screen, CR and DR (X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가)

  • An, Byeong-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • The objective of this study was to compare the resolution and density appropriate to diagnosis in chest PA radiography. In comparing the resolution, we radiographed with conventional radiography, computed radiography(CR) and digital radiography(DR) using the linear resolution phantom(Nuclear Associates-Carle Place. N.Y.). 2 radiologists and 3 radiological technologists read the resolution value by the blind test. DR, conventional radiography and CR measured 3.95, 3.58, 3.48 resolution value respectively. In analysing the density, we chose the fifty normal chest CR and DR and conventional film. We estimated the density using by densitometer(X-rite company-Model 301) in seven regions(lung field, lung field margine, mediastinum I, mediastinum II, heart shadow I, heart shadow II, diaphragm) of chest film. We adapted to analysis the Japanese chest X-ray evaluating method and table. It was scored 0(farthest density value) to 2(nearest density value). DR scored 2 at mediastinum I, mediastinum II, heart shadow I, heart shadow II and diaphragm. On the contrary with, CR scored 2 at lung field and lung field margine. Consequently, DR superior than CR and conventional radiography film compairing density and resolution. It was due to small pixel size and post processing algorithm with digital radiography.