• Title/Summary/Keyword: 유효 온도

Search Result 963, Processing Time 0.029 seconds

An Experimental Study for Estimation of Effective Temperature for Design in Steel Box Girder Bridge (강박스거더교의 설계 유효온도 산정을 위한 실험적 연구)

  • Lee, Seong Haeng;Shin, Hyo Kyoung;Kim, Kyoung Nam;Jung, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.449-458
    • /
    • 2016
  • The temperature data were measured for two years in a bridge specimen and the bridge in service nearby in order to calculate the effective temperature for thermal loads in steel box girder bridge. The maximum and minimum effective temperatures were calculated in the bridge specimen and the bridge according to air temperature in 2014, 2015 and 2years. The effective temperatures calculated in this study were compared the Euro code and the Highway Bridge Design Criteria. The coefficients of determination in the maximum effective temperature and the Euro code for 2 year were calculated from R = 0.927, R = 0.894 in a bridge specimen and the bridge respectively. Those of minimum temperature and the Euro code were analyzed from R = 0.992, R = 0.813 in two bridge respectively. Also, the results were evaluated as being very similar, or slightly increased as compared with the maximum temperature of the Korean Highway Bridge Design Code(Limit State Design).

Evaluation of Effective Temperature for Estimate Design Thermal Loads in Steel Deck of Steel Box Girder Bridges (강상자형교의 강바닥판에서 설계온도하중을 위한 유효온도 산정)

  • Shin, Dong-Wook;Kim, Kyoung-Nam;Choi, Chul-Ho;Lee, Seong-Haeng
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.77-87
    • /
    • 2013
  • A present LSD (limited state design) code for temperature load in the domestic bridge design has applied a uniform standard for various bridge types. In this study, in order to calculate the effective temperature, a specimen of steel box girder bridge section with real size dimension was manufactured. For a year, the temperature data were measured at the 18 point in steel deck of steel box girder bridges specimen. Effective temperature within the cross section according to atmospheric temperature was calculated by this experiment data. The analyzed results were very similar correlation when compared with the effective temperature of the Euro Code. Therefore, the effective temperature which calculated based on the present data could be used as the basic data in order to present to the appropriate design criteria for the thermal loads on the domestic bridge design.

Experimental Study on the Effective Temperature Calculation of Concrete Box Girder Bridge (콘크리트 박스거더교의 설계 유효온도 산정을 위한 실험적 연구)

  • Lee, Seong-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.740-745
    • /
    • 2020
  • To calculate the reasonable design temperature load of a concrete box girder bridge, one bridge test specimen was made. The temperature gauges installed on the bridge test specimen measured 48 sets of temperature per day at 30-minute intervals during the summer and winter periods of one year. The temperature measured at each station was treated statistically to calculate the trend line and standard error, and the temperature distribution and trend line at the representative station were presented. The maximum effective temperature and the lowest effective temperature were calculated from the air temperature suggested by Euro code. The maximum effective temperature was calculated to be 1.5 to 2℃ higher than the Euro code at 35℃ and above. In comparison, the lowest effective temperature was 0.5 to 1.1℃ lower at -13℃ to-19℃. Compared to the effective temperature of this study according to the highest and lowest 50-year frequency of the Yangsan region, the highest effective temperature was 4.7℃ higher, and the lowest effective temperature was 4.5℃ lower. Considering the increasing climate change and reflecting the results of this analysis, it is deemed necessary to make the current temperature design standards larger.

THE STELLAR COLOR-TEMPERATURE RELATION IN ULTRAVIOLET REGION (자외선 영역에서 별의 색지수와 온도의 상관관계)

  • 최영준;한원용;강영운;이우백
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.321-333
    • /
    • 1998
  • In order to derive the UV color - effective temperature relation, we calculated the effective temperature and ultraviolet color index for about 118 IUE standard stars. Using differential correction method, the effective temperature was obtained by the best fittings of IUE low-dispersion spectra to the Kurucz model (1993), and the UV color index was calculated from the magnitude differences of the UV wavelength between 2750 $\AA$ and 2950 $\AA$. The temperature determined by the Kurucz model fittings was consistent with that obtained by other investigators (Malagnini & Morossi 1990, Malagnini et al. 1986), except for the low temperature stars. The relations between UV color - effective temperature also was similar to that in Kurucz model.

  • PDF

Evaluation of Maximum Effective Temperature for Estimate Design Thermal Loads in Steel Box Girder Bridges (강상자형교의 설계온도하중을 위한 최고 유효온도 산정)

  • Lee, Seong-Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.133-139
    • /
    • 2016
  • In order to obtain a reasonable value for the thermal load to use in designs, a bridge specimen of a full-size steel box girder (bridge) was manufactured. The temperature data were measured at 21 points in the bridge specimen and 19 points in the steel box bridge. The steel box bridge specimen was installed in a similar direction to a nearby real one. The maximum effective temperatures in the bridge specimen and bridge were calculated for air temperatures in the range of $24^{\circ}C{\sim}38^{\circ}C$. The maximum effective temperature of the bridge specimen and bridge showed correlations of approximately 93.2% and 87.4%, respectively, compared with the Euro code. The maximum effective temperature calculated in this study was very close to the Euro code and the maximum temperature of the Highway Bridge Design Criteria. When the effective temperature obtained in the study is combined with the highest temperature calculated from the Contour map for each region, the design criteria for the thermal load in domestic bridge design, taking into consideration the characteristics of each region, can be established.

Modeling for Temperature Dependent Effective ionization Coefficient of Si $p^+n$ Junction Diodes (Si $p^+n$ 접합 다이오드의 온도를 고려한 유효 이온화 계수 모델링)

  • Chung Yong Sung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.9-14
    • /
    • 2004
  • In this paper, temperature dependence of effective ionization coefficient in Si is formulated as a single polynomial function of temperature, which allows analytical expressions for breakdown voltage of Si $p^+n$ junction as a function of temperature. The analytical breakdown voltages agree well with the simulation as well as the experimental ones reported within $3\%$ in error for the doping concentrations in the range of $10^{14}cm^{-3}{\~} 10^{17}cm^{-3}$ at 100K, 300K and 500K.

Temperature Effect on Effective Diffusion Coefficients of Zn and Cd through Column Diffusion Tests (칼럼 확산 실험을 통한 아연 및 카드뮴의 유효확산계수에 미치는 온도영향)

  • Dho, Nam-Young;Lee, Seung-Rae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.3 no.1
    • /
    • pp.13-26
    • /
    • 2002
  • In this study, column diffusion tests for Cd and Zn were conducted at $15^{\circ}C$ and $55^{\circ}C$ to investigate a temperature effect on effective diffusion coefficient. An increase in temperature from $15^{\circ}C$ to $55^{\circ}C$ caused up to ten times larger diffusion coefficient for each heavy metal. Besides, it caused the increased retardation of heavy metals, and hence the effective diffusion coefficient should be overestimated as we use an overestimated retardation factor to calibrate the coefficient. The results of sequential extraction analyses showed that Zn was occluded in carbonate phase and this trend was getting prominent with the increase in temperature. As for Cd, it was partitioned mainly in the exchangeable phase(over 60%) at any temperature.

  • PDF

실환경 데이터 기반 태양전지 모듈 Encapsulation용 EVA UV/온도 가속열화 시험설계

  • Jeong, Jae-Seong;Park, No-Chang;Hyeon, Dae-Seon;Byeon, Gi-Nam;Hong, Won-Sik
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.10a
    • /
    • pp.34.1-34.1
    • /
    • 2011
  • 태양전지 모듈의 25년 이상 보증을 위해 태양전지 모듈을 구성하는 부품 소재의 장기 열화메카니즘 연구가 중요시되고 있다. 그 중 봉지제(Encapsulation) 부품으로 적용되고 있는 태양전지 모듈용 에틸렌 비닐 아세테이트(Ethylene Vinyl Acetate, EVA)는 셀을 보호하는 폴리머 부품으로 장기 열화특성 연구가 중요하다. 따라서 EVA를 가속열화하여 25년 보증 내구성을 보유하고 있는지 연구가 필요하다. 본 연구에서는 태양전지 모듈을 구성하는 재료 중 외부환경에 민감한 폴리머 소재인 EVA의 Ultraviolet (UV), 온도 두 환경스트레스 조건을 적용한 가속수명시험을 수행하고 장기 열화메카니즘을 분석하였다. 시험에 앞서 UV/온도 가속수명시험을 설계하였다. UV/온도 가속조건을 설정하기 위해 실환경에서 변화하는 UV와 온도를 일정한 값으로 나타낼 수 있는 유효 UV (Effective UV)와 유효 온도(Effective temperature)를 도출하였다. 이를 통해 UV/온도 가속조건을 설정하였고 1년 및 25년 동안 EVA에 인가되는 stress와 동일한 양을 인가할 수 있는 시험시간을 결정하였다.

  • PDF

Numerical Study on the Validity of Scaling Law for Compartment Fires (구획 화재의 상사 법칙 유효성에 관한 수치해석 연구)

  • Ko, Gwon-Hyun
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.29-34
    • /
    • 2014
  • In this study, to assess the validity of scaling law which was based on the ventilation factor and utilized in fields of compartment fires, numerical simulations were conducted on full- and 2/5 reduced-scale compartment fires using FDS and simulation results were compared with the previously published experimental data. The numerical modeling used in this study was verified by comparing the predicted temperature at several points of the upper layer with the experiment data. Temperature and concentration distribution inside of compartments and velocity profile at door of compartment are analyzed to assess the validity of scaling law. Comparison between the predicted results on the full- and reduced-scale compartments shows good agreements on the inner compartment flow patterns, outflowing flame patterns from the compartments, and vertical temperature distributions.