Browse > Article
http://dx.doi.org/10.5762/KAIS.2016.17.8.133

Evaluation of Maximum Effective Temperature for Estimate Design Thermal Loads in Steel Box Girder Bridges  

Lee, Seong-Haeng (Department of Civil Engineering, Pusan National University)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.17, no.8, 2016 , pp. 133-139 More about this Journal
Abstract
In order to obtain a reasonable value for the thermal load to use in designs, a bridge specimen of a full-size steel box girder (bridge) was manufactured. The temperature data were measured at 21 points in the bridge specimen and 19 points in the steel box bridge. The steel box bridge specimen was installed in a similar direction to a nearby real one. The maximum effective temperatures in the bridge specimen and bridge were calculated for air temperatures in the range of $24^{\circ}C{\sim}38^{\circ}C$. The maximum effective temperature of the bridge specimen and bridge showed correlations of approximately 93.2% and 87.4%, respectively, compared with the Euro code. The maximum effective temperature calculated in this study was very close to the Euro code and the maximum temperature of the Highway Bridge Design Criteria. When the effective temperature obtained in the study is combined with the highest temperature calculated from the Contour map for each region, the design criteria for the thermal load in domestic bridge design, taking into consideration the characteristics of each region, can be established.
Keywords
Steel box girder bridge specimen; Steel box girder bridge; Maximum effective temperature; Euro code; Temperature measurement;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Ministry of Land, Infrastructure and Transport, Highway Bridge Design Criteria(in Korea)(Limit state design method), 2012.
2 AASHTO LRFD Bridge Design Specifications (SI Units, 4th Edition), pp. 3-104, 2007.
3 British Standards Institution, Steel, Concrete and Composite Bridges, Part 2. Specification for loads, appendix E. BS5400: Part2:1978, pp. 20-23, 2004.
4 Shin, D. W., Kim, K. N., Evaluation of Effective Temperature for Estimate Design Thermal Loads in Steel Deck of Steel Box Girder Bridges, Journal of the korea Institute for Structural Maintenance and Inspection, vol. 17, no. 3, pp. 077-087. 2013. DOI: http://dx.doi.org/10.11112/jksmi.2013.17.6.077   DOI
5 Lee, S. H., Study of the Temperature Difference between the Top and Bottom Web of Steel Box Girder without Concrete Slab by using Gauge Measurement, Journal of the Korea Academia -Industrial cooperation Society, vol. 15, no. 12, pp. 7350-7356. 2014 DOI: http://dx.doi.org/10.5762/KAIS.2014.15.12.7350   DOI
6 Shin, D. W., Kim, K. N., An Experimental Study on the Temperature Difference between the Top and Bottom Flange in Steel Girder without Concrete Slab, Journal of the Korea Institute for Structural Maintenance and Inspection, vol. 18, no. 4, pp. 099-106. 2014. DOI: http://dx.doi.org/10.11112/jksmi.2014.18.4.099   DOI