• Title/Summary/Keyword: 유용도-전달단위수

Search Result 20, Processing Time 0.023 seconds

Numerical Study of Characteristic of Heat and Mass Transfer in Planar Membrane Humidifier According to Flow Direction (연료전지용 판형 막 가습기의 유동방향에 따른 열 및 물질전달 특성에 관한 해석적 연구)

  • Yun, Sungho;Byun, Jae Ki;Choi, Young Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.503-511
    • /
    • 2013
  • The humidifying supply gas is important in terms of the performance efficiency and membrane life improvement of a PEM fuel cell. A planar membrane humidifier is classified as a cross-flow and counter-flow type depending on the flow direction, and heat and mass transfer occur between the plate and the membrane. In this study, the changes in heat and mass transfer for various inlet temperatures and flow rates are compared according to the flow direction by using the sensible and latent ${\varepsilon}$-NTU method. The obtained results indicate that the counter flow shows higher heat and mass transfer performance than the cross flow at a low flow rate, and the difference in performance decreases as the flow rate increases. Furthermore, changes in the mass transfer performance decrease considerably with a nonlinear increase in the inlet temperature, and variations of the heat transfer performance are small.

Energy and Entransy Characteristic Analysis of Heat Exchangers Depending on Heat Exchanger Type (열교환기 형식에 따른 열교환기의 에너지 및 엔트랜시 성능 특성 해석)

  • KIM, KYOUNG HOON;JUNG, YOUNG GUAN;HAN, CHUL HO
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.31 no.1
    • /
    • pp.112-121
    • /
    • 2020
  • In this work energy and entransy characteristics of heat exchangers are analyzed for 12 different flow arrangements of heat exchangers. The dimensionless parameters are number of entransy dissipation (Ng), number of entransy dissipation-based thermal resistance (Nr), and entransy dissipation-based effectiveness of heat-exchanger (εg). The dimensionless parameters are expressed analytically in terms of the effectiveness of heat exchanger (ε), heat capacity ratio (c), and number of transfer unit (N) for optimal performance of heat exchangers. Results showed that the dimensionless parameters based on the entransy dissipation can be useful concepts for optimal design of heat exchangers.

Effects of flow direction on the performance of an indirect evaporative cooler (유동 방향이 간접 증발식 냉각기 성능에 미치는 영향)

  • Choo, Hyun-Seon;Lee, Kwan-Soo;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.743-748
    • /
    • 2006
  • Ren et al. analyzed the performance of the indirect evaporative cooler according to the direction of the flow considering evaporation water flow and wetness. However the effect of NTU of each channel on the performance of the indirect evaporative cooler according to the direction of the flow was not analyzed exactly. In this study the effect of the direction of the flow on the Indirect evaporative cooling performance changing NTU of each channel are investigated theoretically. The cooling process of the indirect evaporative cooler by flow direction is modeled into a set of linear differential equations and solved to obtain the exact solutions to the temperatures of the hot fluid, the moist air, and evaporation water. Based on the exact solution in the case of different NTU of each channel, we study the change of the distribution of the temperature according to each flow direction and at the same time analyze the effect of the flow direction on the cooling performance.

  • PDF

Simulator Development and Analysis for Signal Flow Pathway in Vertebrate Retina (척추동물 망막의 신호 전달 경로 시뮬레이터 개발 및 분석)

  • Baek, Seungbum;Jang, Young-Jo;Cho, Kyoungrok
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.655-664
    • /
    • 2018
  • Retina transforms the external light into electrical signal that stimulates visual cortex of the brain. Electrical modeling of the retina is useful to understand its structure and action that is a prerequisite to implement the retina as a hardware device. This paper introduces a 2-D electrical network model of vertebrate's retina considering signal pathway of retinal cells and synapses. We implemented a simulator of the retina based on the electrical network model to analyze its operation under various circumstances. Compared to the prior studies, It might contribute designing of artificial retina device in terms of that this study specifically observed input and output reactions of each cell and synapse node under various light intensity on the retina.

A Nuclide Transfer Model for Barriers of the Seabed Repository Using Response Function (응답함수를 이용한 해저처분장의 방벽에 대한 핵종전달 모델)

  • Lee, Youn-Myoung;Kang, Chul-Hyung;Hahn, Pil-Soo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.2
    • /
    • pp.175-184
    • /
    • 1996
  • A nuclide transfer by utilizing mass transfer coefficient and barrier response function defined for each barrier is proposed, by which the final nuclide transfer rate into the sea water can be evaluated. When simple and immediate quantification of the nuclide release is necessary in the conservative aspect, using this kind of approach may be advantageous since each layered barrier can be treated separately from other media in series in the repository system, making it possible to apply separate solutions in succession to other various media. Although one disadvantage is that while flux continuity can be maintained at the interface by using the exit nuclide flux from the first medium as the source flux for the next one, there may be no guarantee for concentration continuity, this problem could be eliminated assuming that there is no boundary resistance to mass transfer across the interface. Mass transfer coefficient can be determined by the assumption that the nuclide concentration gradient at the interface between adjacent barriers remains constant and barrier response function is obtained from an analytical expression for nuclide flow rate out of each barrier in response to a unit impulse into the barrier multiplied by mass transfer coefficient. Total time-dependent nuclide transfer rate from the barrier can then be obtained by convoluting the response function for the barrier with a previously calculated set of time-varying input of nuclide flow rate for the previous barrier.

  • PDF

Modeling of Microalgal Photosynthetic Activity Depending on Light Intensity, Light Pathlength and Cell Density (빛의 세기, 투과거리 및 세포농도에 따른 미세조류의 광합성 활성 모델링)

  • Yun, Yeong-Sang;Park, Jong-Mun
    • KSBB Journal
    • /
    • v.14 no.4
    • /
    • pp.414-421
    • /
    • 1999
  • The influenced of light intensity, cell density, and light pathlength on photosynthetic activity of Chlorella vulgaris were investigated. Since the light respon curve varied according to reaction conditions, the parameters estimated from nonlinear regression were proved to be apparent and could not be applied to various situations. The light response model incorporating the light penetration through the microalgal suspension was developed based upon the spatial distribution of the photosynthetic activity. This model showed a good agreement with experimental data at different cell densities and light intensities. Using the model the effects of cell density and light pathlenth were simulated and some dicussions about optimization of operation conditions of photobioreactors were carried out. Concludingly, the developed model can be useful for predicting microalgal photosynthesis and for determining the optimal operating conditions.

  • PDF

Analysis of water quality smart meter data using dynamic time warping (Dynamic Time Warping을 이용한 수질 스마트미터 데이터 분석)

  • Lim, Soyeon;Jung, Donghwi
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.173-173
    • /
    • 2021
  • 현재까지 상수도관망 내 수질적 거동에 대한 분석은 (1) 네트워크 수질 모델(EPANET 수질모의 등)에 기반한 방법과 (2) 시공간적 저해상도 데이터에 기반한 데이터 분석법이 주를 이루었다. 그러나 현존 네트워크 수질 모델은 수질 사고의 복잡한 물리·화학적 거동을 상세히 모의하기 어렵다. 반면 계측 및 통신기술의 발달로 고해상도 수질 데이터의 실시간 수집이 가능해지면서 사고의 사전감지, 발생시 즉각적 탐지 및 대응을 위한 데이터 분석법에 관심이 증가하고 있다. 서울 문래동, 인천, 포항의 경우에서도 알 수 있듯이, 수질사고 발생 시 원인물질의 시공간적 이송 또는 전파에 대한 정보는 사고대응에 유용하게 활용된다. 본 연구는, 비정상적인 수질변화의 계통 내 전달 시간을 계산하기 위해 고해상도 수질 스마트 미터 데이터에 기반한 데이터 분석법을 개발하였다. 물공급 하류방향의 수질변화 전달 시간 정량화를 위해 화음탐색법 기반 동적시간워핑(Dynamic time warping; DTW) 기술을 이용하였고, 원데이터의 전처리를 위해 이동평균필터링을 수행하였다. 개발된 분석법은 A시 생산 및 배·급수과정의 감시지점에서 10초 단위로 계측된 다양한 수질변수(pH, 탁도, 잔류염소, 전기전도도, 수온 등)의 공간적 변이 전파시간을 결정하기 위해 적용되었다. 분석에 활용한 데이터는 데이터 통신 및 측정 기기에 의한 이상값과 운영상황의 변화에 따라 변동한 값을 처리하기 이전의 데이터이다. 데이터 품질에 의한 영향을 배제하기 위해 이상값이 발생하지 않은 기간을 파악한 후, 그 기간에 대하여 분석하였다. 계통 내 위계에 따라 두 지점의 측정값의 전파시간을 정량화한 결과, 지점에 따라 전파시간이 다르게 나타났다. 또한, 같은 두 지점에 적용한 결과라도 DTW를 적용하는 기간과 이동평균필터링의 크기에 따라 수질변화 전달 시간이 다르게 나타나는 것을 확인할 수 있었다. 본 연구에서 개발된 분석법은 다변량 수질변수 간의 영향관계를 파악하는데 확장 적용이 가능하다. 또한, 이 방법의 실시간 적용을 통해 동적으로 변화하는 전달시간을 주기적, 공간적으로 갱신하여 관망 수질 변화 모니터링이 가능하다.

  • PDF

Investigation on the Cooling Characteristics of a Regenerative Evaporation Water Cooler (재생증발식 수냉각기의 냉각성능 해석)

  • Choi Bong-Su;Hong Hi-Ki;Lee Dae-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.393-401
    • /
    • 2006
  • The regenerative evaporation water cooler is devised and analysed in this study. The regenerative evaporation water cooler is composed of a sensible heat exchanger to cool the incoming air, followed by a latent heat exchanger to cool the water evaporatively with the cooled air flowing out of the sensible heat exchanger. By linearizing psychrometric characteristics, the heat and mass transfer in the regenerative evaporation water cooler is analyzed theoretically. The results show that the water can be cooled down even lower than the wet-bulb temperature of the inlet air. When the inlet air is $32^{\circ}C$ and 20% in relative humidity, and the inlet temperature of the water is $20^{\circ}C$, the regenerative evaporation water cooler provides a larger cooling capacity than the conventional evaporation water cooler if the effectiveness of the latent heat exchanger is higher than 0.6 and that of the sensible heat exchanger is higher than 0.5.

Information Delivery Requirements of Steel Structure according the Structural Design Stages using IDM (IDM을 이용한 강구조의 구조설계 단계별 정보전달 요구 분석)

  • Lee, Jae-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1467-1473
    • /
    • 2013
  • In construction project, it is important to exchange and share the digital information generated by their own professional softwares. So this paper analyzed the information delivery requirements of steel structure according the structural design stages using IDM methodology. For schematic design stage and detailed design stage, the structural design information to share in each design stages is abstracted by defining the PM, ER, and FP. The new ERs and FPs are proposed by defining the new property sets(Psets), suchlike bolt gauge line, weld, scallop, and cope, to complement the structural design information of $IFC2{\times}3$. Finally, the reasonability of the proposed new ERs, FPs are verified by applying them to represent the standard steel connection sample in detailed design stage. As a result, the structural design information of standard steel connection could be stored and managed sufficiently by using the proposed new ERs and FPs.

Heat Exchanger Ranking Program Using Genetic Algorithm and ε-NTU Method for Optimal Design (유전알고리즘과 ε-NTU 모델을 이용한 다양한 열교환기의 최적설계 및 성능해석)

  • Lee, Soon Ho;Kim, Minsung;Ha, Man Yeong;Park, Sang-Hu;Min, June Kee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.11
    • /
    • pp.925-933
    • /
    • 2014
  • Today, computational fluid dynamics (CFD) is widely used in industry because of the availability of high-performance computers. However, full-scale analysis poses problems owing to the limited resources and time. In this study, the performance and optimal size of a heat exchanger were calculated using the effectiveness-number of transfer units (${\varepsilon}-NTU$) method and a database of characteristics heat exchanger. Information about the geometry and performance of various heat exchangers is collected, and the performance of the heat exchanger is calculated under the given operating conditions. To determine the optimal size of the heat exchanger, a Genetic Algorithm (GA) is used, and MATLAB and REFPROP are used for the calculation.