• Title/Summary/Keyword: 유량 제어 밸브

Search Result 210, Processing Time 0.027 seconds

A Design and Implementation of CO2 Infuser for a Carbon Dioxide (카복시 테라피용 CO2 주입기의 설계 및 구현)

  • Park, Sung-Kon;Ahn, Chan-Jin
    • Journal of Digital Contents Society
    • /
    • v.16 no.3
    • /
    • pp.483-492
    • /
    • 2015
  • This thesis analysis the CARBO 3000 that is one of a $CO_2$ infuser and improve its effectiveness. The thesis designs H/W and S/W that controls the $CO_2$ infusing mass compared to the CARBO 3000. Specially the designed H/W has a newly CPU, LCD, a flow velocity controller, a solenoid valve and a flow sensor. Also the designed S/W is composed of GUI and the algorithm to control the $CO_2$ infusing mass. The designed and implemented the $CO_2$ Infuser in this thesis is tested for the performance. The commercial measuring sensor is used for the test. The testing results say that the designed and implemented the $CO_2$ Infuser in this thesis is much more accurate compared to the CARBO 3000 on $CO_2$ infusing.

Infinitesimal Fluid Injection Control System by using an Orifice and a Directional Control Valve (오리피스와 방향제어밸브를 이용한 미세유량 분사제어시스템)

  • Jeong, Eun-Seok;Oh, In-Ho;Lee, Ill-Yeong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.67-68
    • /
    • 2006
  • This study suggests a precision flow control system that enables fluid injection of a few grams at a time in a few ms time duration. The fluid injection system suggested here consists of a high pressure fluid pump, a 3 way 3 position directional control valve, an injector and an orifice. The orifice is located between the directional control valve and the injector. By supplying current signal to the directional control valve, the prescribed small amount of fluid can be supplied to a plant through the injector. The control robustness of the suggested system against the disturbances like the pressure change in a plant and the viscosity variation of the injected fluid is secured easily by using an orifice with very small inside diameter and setting the supply pressure with comparatively high value. The control performances of the suggested system are verified by numerical simulations and experiments. The outcomes of this research could be applied to the common rail injection control of lubrication oil for large size marine diesel engines, and other industrial plants.

  • PDF

Design of a bilinear robust controller for a hydrostatic driver (Hydrostatic 구동기에 관한 Bilinear 강인 제어기 설계)

  • Park, R.W.;Cho, S.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.65-74
    • /
    • 2011
  • 이 논문은 비선형 시스템에 대해 bilinear 강인제어기를 설계하는 새로운 방법을 제시한다. 이 설계방법은 골칫거리인 비선형 영향을 나타내는 무거운 질량을 가지고 진동하는 시스템을 제어하기 위한 새로운 대안이고 진전된 방법이다. 이 설계 과정에, hydrostatic 구동기로 구동되는 킬(용골)이 주어진다. 첫 단계로 킬은 물리적으로 여러 한정된 질량으로 모델화된다. 물리적 모델에 근거한 수학적인 모델을 유도하는 방법은 해밀턴 원리를 적용한 유한요소법을 사용하였다. 즉, 수학적 모델은 여러 서브시스템으로 구성된다. 이것은 주어진 물리적인 시스템에 대해 기준이 되는 시스템이다. 회전하는 구동기에 대한 물리적 모델에 근거하여, 과도 거동은 구동기의 베어링에서 측정되는 운동 현상으로부터 유도된다. 물리적인 시스템은 bilinear 시스템으로 구성하였다. 이 시스템에 근거하여, 요트 킬의 거동을 제어하도록 bilinear 관측기를 설계한다. 구동기의 속도, 토크, 밸브에서의 유량 등이 관측기를 구성하는데 필요한 데이터들이다. 시뮬레이션 결과에 의하면 비선형성에 대한 추정과 보상을 통하여 무거운 질량을 갖는 회전축에 대한 위치와 힘을 제어하는 설계에 유용한 접근법임이 증명되었다.

A Study on the Frequency Response Characteristics of High Response Flow Control Servo Valve (고 응답 유량제어 서보밸브의 주파수 응답특성에 관한 연구)

  • 서종수;신유식;지명국;전영흥;정효민;정한식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.480-488
    • /
    • 2003
  • The purpose of this research Is to derive the principal design parameters governing the dynamic characteristics of the high response flow control servo valve. For this purpose, a numerical modeling of the servo valve system and a parameter sensitivity analysis to a frequency response characteristics was peformed. As a result of these analysis, a basis for improvement of a dynamic characteristics of servo valve was arranged.

Microdisplacement Control Microactuator (미세거리 조정 마이크로 액투에이터)

  • Park, Se-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.345-348
    • /
    • 1989
  • A small linear incremental device, which is called a microworm, is introduced, and this paper explains working principle, design considerations and theoritcal force analysis of the microworm. A fluid control microvalve and a piezoelectric motor as an application of the microworm are explored for feasibility.

  • PDF

An Investigation of 3 Port ER Valve for Controlling Electro-Rheological Fluids (ER유체 제어용 3포트 ER 밸브의 성능 고찰)

  • Jang, Sung-Cheol;Yum, Man-Oh
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.41-47
    • /
    • 2007
  • The structure of ER valve is simple that its designing and manufacturing are easy. The flow rate and pressure of ER fluids flowing in the ER valve are controlled only by electric field. In this study a three port ER valve is designed and manufactured. Then, the flow rate and pressure dorp of ER fluids flowing in the ER valve are measured. The system proposed controls flow rate and pressure fast. So, this system can be easily substituted for the existing hydaulic and pneumaitc control system.

Setup Procedure of Dump Valve for Full-Scale Airframe Test (전기체 구조시험의 덤프밸브 조절절차 개발;)

  • Kim, Sung-Chan;Kim, Sung-Jun;Hwang, In-Hee
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1252-1257
    • /
    • 2003
  • This paper present a procedure of meter-out flow control method for dump valve in full-scale airframe test. Emergency stop, which results in dump state, can be happened during full-scale airframe test by several causes. Because servo valve can't control hydraulics actuator in the dump state, pressure in cylinder chamber may rise abruptly and overload can be acted to the test article. In this paper, the procedure and technology of orifice setting are investigated to protect the test article from unexpected loads by dump. The test results show that the presented methods decrease peak loads and improve unloading characteristics of hydraulic actuators in the dump state.

  • PDF

Case of Improving Design by Using Analysis Model of Hydraulic System for Dental Chair (치과용 유니트체어 유압구동 시스템 해석모델을 활용한 개선설계 사례)

  • Dae Kyung Noh;Dong Won Lee;Taek June Kim;Joo Sup Jang
    • Journal of Drive and Control
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • This study aims to develop a Korean dental chair hydraulic circuit by improving the existing equipment in order to localize foreign leading companies' products. The suggested Hydraulic circuit can be applicable to varied sectors where height and backrest angle control of chair-type equipment are required. The study followed the steps below. First, three kinds of foreign hydraulic circuits were analyzed and three kinds of Korean dental chair hydraulic circuits were suggested. Second, it was determined whether the three kinds of Korean hydraulic circuits operate normally through SimulationX, a software specialized in multi domain analysis, and the effectiveness of each circuit was examined.

A LPG Dispensing Control System based on a 16-bit Microprocessor (16-bit 마이크로프로세서로 구현한 LPG 충전 제어 시스템)

  • 이상훈;홍남관
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.3 no.2
    • /
    • pp.83-88
    • /
    • 2002
  • In this paper, a POS interfacing and temperature compensable LPG dispensing control system(LDCS) has been developed. A LDCS includes a 16-bit 80C196 microprocessor, RAM, ROM, video driver, and programmable peripheral devices. Based on gas flow encoding pulse, temperature-voltage conversion values and apparatus calibration values, the LDCS controls the LPG dispensing quantity with switching on or off the solenoid valves. The temperature compensation is performed with a 10-bit A/D conversion and its range is from +7$0^{\circ}C$ to -3$0^{\circ}C$ with a 0.5$^{\circ}C$ resolution.

  • PDF

Control of High-Pressure Exhaust Gas Flows Using Shock-Wave Confinement (충격파 감금법을 이용한 고압배기가스 유동의 제어)

  • ;;K.Matsuo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.19-19
    • /
    • 1998
  • 최근 화학, 연소, 동력, 제철 등의 각종 플랜트에서 조업압력이 고압화되어 가고 있으며, 이에 수반하여 배관계를 통하는 고압가스 유동에 관한 연구가 활발하게 진행되고 있다. 배관계를 통하는 고압가스의 유동에 있어서 유량의 적절한 제어, 유동에 의하여 야기되는 배관계의 소음·진동, 그리고 배기가스의 적절한 처리법 등은 공학적으로 매우 중요한 문제로 알려져 왔다. 일반적으로 정상운전을 하는 플랜트에서 고압 배기가스의 문제는 배기가스 Expander에 의하여 에너지를 회수하는 방법이 생각될 수 있으나, 실제 공업현장에서는 배기가스를 안전하고, 또 소음·진동을 발생시키지 않도록 적절하게 처리하는 것이 매우 중요한 기술적 과제로 남아 있다. 일반적으로 배기가스의 압력이 임계압력(critical pressure) 이상으로 되는 경우(실제 대부분의 플랜트에서 배기가스의 압력은 임계압력보다 매우 높다), 배관계 내부에서 충격파(shock-wave)가 발생하여 난류와동 혹은 난류경계층과 간섭하게 됨으로써 강력한 공기역학적 소음이나 진동을 발생시키게 된다. 이와 같은 소음·진동에 대한 대책으로는 현재 가스배출부에 감압밸브를 직렬로 설치하거나, 유로에 다공판(porous plates)들을 삽입하여 감압과정을 공간적으로 분산시킴으로써, 충격파가 발생하지 않도록 하는 방법을 주로 채택하고 있다. 그러나 이러한 방법을 적용하는 경우 배기가스 유동에 대한 유량의 제어기능이 저하되는 문제가 발생한다.

  • PDF