• Title/Summary/Keyword: 유동 양식

Search Result 112, Processing Time 0.021 seconds

Experimental study on two-phase flow behavior inside a vertical tube evaporator under flashing phenomenon (후래시 현상을 수반하는 수직증발관내에서의 2상유동에 관한 실험적 연구)

  • 이상용;송시홍;이상호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.833-846
    • /
    • 1988
  • Two-phase flow heat transfer phenomena with flash evaporation inside a vertical tube were studied experimentally. Void fractions were measured using electrical probes, and the flow patterns were identified from the output voltage signal itself. The flow pattern as well as the beat transfer rates were changing along the axial distance from the tube inlet with the system pressure. As the pressure inside the tube decreases with fixed inlet temperature, the overall heat transfer coefficient through the tube wall and the boiling heat transfer coefficient inside the tube increase whereas the condensation heat transfer coefficient outside the tube decreases. The boiling heat transfer coefficient inside the tube measured by the experiments appeared to be somewhat larger than the value obtained from the Chen's correlation. Also, the flow patterns identified from present experiments are at the larger quality region of the low pattern map based on the transition criteria of Mishima and Ishii. This may be due to the non-equilibrium flashing phenomenon occurred at the nozzle exit and the tube inlet ; this also implies that the flow pattern of the two-phase flow depends strongly on the inlet conditions.

경사유로내에서 유동비등에 관한 실험적 연구

  • 이태호;김문오;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.10a
    • /
    • pp.487-494
    • /
    • 1997
  • 비등이 발생하는 경사유로에서 이상유동 구조 파악을 위해 국부적 이상유동 변수의 측정이 이루어졌다. 국부 기포율, 국부 기포빈도, 국부기포속도 그리고 국부 기포크기와 같은 기상 관련 이상유동변수는 이중 전기전도도 탐침으로, 액상속도 분포는 Pilot tuba로 측정하였다. 유로의 경사도가 이상유동 구조에 미치는 영향을 파악하기 위해 실험은 수직, 수직으로부터 30도 경사도 및 60도 경사도에서 유량과 열유속을 변화시켜가며 수행하였으며 유동변수의 측정은 경사진 경우에 측면 방향으로의 대칭성을 고려하여 유로 반 단면내 총 91개 지점에서, 수직인 경우에는 13개 지점에서 이루어졌다. 유동조건은 1.4m/s 이하의 평균 액상 겉보기 속도에 제한되었고 유로내 압력은 대기압이며 유동양식은 미포화 비등에 국한되었다. 측정된 이상유동 변수의 분포를 이용하여 경사유로에 적용할 수 있는 distribution parameter와 drift velocity 같은 dirft flux parameter에 대한 상관식이 개발되었다.

  • PDF

통영연안 해역의 물리화학적 특성

  • 박병수;김정균
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2001.05a
    • /
    • pp.69-70
    • /
    • 2001
  • 통영 인근해역은 해안선의 굴곡이 심하고 많은 섬들이 산재하여 복잡한 해수유동의 양상을 보인다. 해역 내에는 각종 양식어장과 정치망 등이 조밀하게 배치되어있어 해수유동을 저해하고 자가오염으로 인하여 수질은 악화되고 있는 실정이다. 본 연구에서는 미륵도 주변에 5개의 정점을 선정하여 계절별 수질변화를 측정하였다. 그리고 해수유동과 수질과의 관계를 파악하기 위하여 정점별로 유속관측을 병행하였으며 수온, 염분과 유속을 연속 측정하여 상호간의 상관관계를 구명하고자 하였다. (중략)

  • PDF

Examine the Proper Operating Conditions in the Seawater Fluidized Bed filter System (해수 유동층 여과시스템의 적정 운용 조건)

  • Son Maeng-Hyun;Cho Kee-Chae;Jeon Im-Gi;Lim Han Kyu;Park Min-Woo
    • Journal of Aquaculture
    • /
    • v.18 no.4
    • /
    • pp.280-286
    • /
    • 2005
  • Experiments were conducted to examine the differences in ammonia removal rates with the different filter media between sand and zeolite, the expanding rates between $50\%$ and $100\%$, the water temperatures between $15^{\circ}C$ and $25^{\circ}C$, and the ammonia loading rates between 2 mg/L and 5 mg/L in the seawater fluidized bed filters system (FBF). The 2.1 m high FBF (8.3 cm diameter) consisted of the clear acrylic for the upper half and a PVC pipe for the lower half, Sand and zeolite were used as the filter media in sizes of 0.5$\pm$0.1mm. Each biofilter contained 5.4 L of media. The ammonia removal rates of the biofilter were higher at the $25^{\circ}C$ water temperature than those of the biofilter at $15^{\circ}C$ water temperature, and higher at the $50\%$ expanding rate of filter media than those of the biofilter at $100\%$ expanding rate of filter media. Also, the ammonia removal rates of FBF were higher at 5 mg/L ammonia concentration than those of FBF at 2 mg/L ammonia concentration in rearing water. With these better conditions the ammonia removal rates of FBF per day are practically acceptable and ranged ken 80.6 to $210.6g/m^3$.

Flow pattern characteristics in vertical two phase flow by PDF and signals from conductance probe (確率密度函數와 電導 Prode信號에 의한 垂直二相流의 流動樣式特性)

  • Son, Byung-Jin;Kim, In-Suhk;Lee, Jin
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.814-822
    • /
    • 1986
  • Flow patterns and its transitions in vertical two phase flow of air-water isothermal flow are identified objectively by void output signals and moments computed from the Probability Density Function which is associated with the statistical measurement for time average local void fractions using conductance probe. It has been shown that the probe output signals, PDF distributions and its moments are deterministic criteria of flow pattern and transition classification.

Identification of Two-phase Flow Patterns in a Horizontal Tubular Condenser (수평 응축관내 2상유동양식의 판별에 관한 연구)

  • Lee, S.C.;Han, Y.O.;Shin, H.S.;Lee, H.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.65-72
    • /
    • 1993
  • An experiment has been carried out to identify flow patterns in a horizontal condensing flow with R-113. Characteristics of flow patterns were determined based upon a statistical analysis of differential pressure fluctuations at an orifice. The probability density function and power spectral density function of instantaneous pressure drop curves for various flow conditions were obtained. In comparison to the results of air-water flows, the flow patterns in a condensing flow such as annular, wavy, slug and plug could be identified. The experimental data determined by this technique were compared with the flow pattern maps suggested by other investigators. The result indicates that the statistical characteristics of differential pressure fluctuations at an orifice may be a useful tool for identifying flow patterns both in condensing flows and in adiabatic two-phase flows.

  • PDF

Experimental Study of the Refrigerant Induced Noise for Air Conditioner Using Flow Pattern Map (유동 양식 선도를 이용한 에어컨 실내기의 냉매 소음 저감 분석)

  • Han, Hyung-Suk;Mo, Jin-Yong;Jeong, Weui-Bong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.957-963
    • /
    • 2008
  • The refrigerant-induced noise of the air conditioner is one of the irregular noises which occurs at the indoor unit. Because the air-conditioner makers are always trying to reduce the sound pressure level radiated from indoor unit, reducing the refrigerant-induced noise at low cooling mode is very important problem. But it is very difficult to estimate whether the refrigerant-induced noise occurs or not before it becomes problem. In this paper, a method to predict the refrigerant-induced noise is suggested using flow pattern map. It is estimated that the irregular noise from the refrigerant comes from the slug flow in a pipe.

  • PDF

Study on the Rheological Properties of the Lactic acid Fermented Milk (유산균배양액의 유체역학적 성질에 관한 연구)

  • 정후길;강국희
    • Journal of Food Hygiene and Safety
    • /
    • v.5 no.1
    • /
    • pp.35-40
    • /
    • 1990
  • As a link in the studies on the extracellular polysaccharide by lactic acid bacteria, the experiment was conducted to investigate the viscosity variations and rheological properties of 10% reconstituted skim milk and 12% reconstituted whole milk, respectively. 1. 10% reconstituted skim milk cultured by Str. thrennophilus 510 showed strong flow property of pseudoplastic fluid depending upon the production of exopolysaccharide. And the viscosity reached the highest value within 14% concentration. 2. 12% reconstituted whole milk cultured by lactic acid bacteria indicated flow property of pseudoplastic fluid. But there was a big difference in the viscosity as compared with 10% skim milk. 3. The maximum consistency index (k) and the minimum flow behavior index (n) of the fermented milk by Str. thermophilus 510 were 43 and 0.09, respectively. They were 35 and 0.09, in case of Lb. bulgaricus.

  • PDF

Effect of Various Shapes of Mixer Geometry on Two-Phase Flow Patterns in a Micro-Channel (마이크로 채널 내 혼합부 형상이 2상 유동 양식에 미치는 영향에 대한 연구)

  • Lee, Kwan Geun;Lee, Jun Kyoung;Park, Taehyun;Kim, Gyo Nam;Park, Eun Ju
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.2
    • /
    • pp.75-80
    • /
    • 2015
  • The effect of inlet mixer geometries on the two-phase flow patterns in square micro-channel with $600{\times}600{\mu}m$ was investigated experimentally in this paper. The 4 different mixer configurations based on the Y, Impacting, and two T types (gas and liquid inlets were switched) were used. The test fluids were nitrogen and water. The liquid and gas superficial velocities were 0.01~10 m/s and 0.1~100 m/s, respectively. Several distinctive flow patterns, namely, annular, slug-annular, slug, slug-bubbly, bubbly, and churn flow could be seen. The flow pattern maps for each mixer were suggested, and it can be concluded that two-phase flow patterns are not very sensitive to the mixer geometries. But the mixing behaviors of gas and liquid for each mixer were different for slug and bubbly flow. Thus, the characteristics of slug and bubble for each case were not same.

A Study on the development of the aquaculture fishcage for the open sea (외해용 양식 구조물 개발에 관한 연구)

  • Shin, Jong-Keun;Jeong, Seong-Jae;Yoon, Ji-Hyun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.29 no.1
    • /
    • pp.285-290
    • /
    • 2005
  • Until now, korean aquaculture industry has been grown largely from a quantitative viewpoint. However, an increase of quantity has caused lots of problems producing a derived effect recently. Nearly 82% of korean aquaculture farms had been installed mainly at inshore of the southern sea and also sewage, factory wastes, high density of fishcage at the limited area and autoinfection have deteriorated inshore fisheries. The offshore have been on the rise for the solution to these problems since it has clear seawater reduces the environmental pollution with much current. As a matter of fact, the existing inshore fishcage facilities have trouble advancing to the offshore due to the rough environmental conditons such as a high sea, strong currents etc.; therefore, it is necessary to develop a new cultivating equipment fit the open sea conditons. In this research, the theoretical study and experimental analysis have been carried out for the fishcage design of the structure which is able to use at the open sea.

  • PDF