• Title/Summary/Keyword: 위치 편차

Search Result 605, Processing Time 0.029 seconds

A Study on the Axial Dependence of the Traffic Distribution Function (통항분포함수 축방향 의존성에 관한 연구)

  • Yoo, Sang-Lok;Gang, Sang-Geun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.2
    • /
    • pp.179-187
    • /
    • 2015
  • The purpose of this study is to identify the aspect that the traffic distribution function changes, according to the direction of the datum line and the horizontal and vertical positions of the datum point applied when it is calculated. Targeting routes at the entrance of Mokpo Harbor, this study tested using AIS survey data of January 2013 the effects of the three variables-direction of the datum line(${\theta}$), horizontal position($\mathfrak{L}_H$) and vertical position($\mathfrak{L}_V$) on mean ($\bar{x}$) and standard deviation (${\delta}$). The test result showed that $\bar{x}$ and ${\delta}$ were changed according to the change of ${\theta}$, because the extracted sample data were changed according to ${\theta}$; and the changes of $\bar{x}$ and ${\delta}$ according to ${\theta}$ were drawn as the relation of the sine function' sum. In addition, it was found that setting up ${\theta}$ that the change value of ${\delta}$ becomes the least as the direction of the datum line was valid, to determine the optimum passage distribution function on complex waters with multiple branches of route. The result of this study is expected to be used as basic data to understand maritime traffic flow based on more quantified data of normal distribution and make decisions related to maritime traffic safety management.

Development of Automatic System to Measure Transmitted Ultrasonic Speed of Raw Ginseng (수삼의 초음파 전달속도 계측 자동화 시스템 개발)

  • 서동현;김기대;강호양;김찬수;이현동
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2002.02a
    • /
    • pp.592-599
    • /
    • 2002
  • 본 연구에서는 수삼의 가공전 선별을 위해 현장에서 편리하게 사용할 수 있는 초음파 전달 속도 계측 자동화 시스템을 개발하여 그 성능을 평가하고자 하였으며 결과를 요약하면 다음과 같다. 1. 개발된 시스템은 제어용 컴퓨터, 시스템 구동 및 탐촉자 이동 장치, 하중 변환장치, 초음파 발생 및 송수신 장치 등으로 구성되었다. 2. 제어 및 계측용 프로그램은 압축력, 측정 대상물의 크기, 초음파 전달 시간을 순차적으로 계측하여 초음파 전달 속도를 계산하는 알고리즘을 개발하였으며, Visual Basic 6.0으로 작성되었다. 모터의 작동, A/D 변환, RS232C 통신 등과 관련된 부분은 각각의 모듈화된 함수로서 구동하고자 하였다. 3. 개발된 시스템의 속도와 거리별 이동 거리별 오차를 측정한 결과 0∼0.04mm 범위를 나타내었다. 이 값은 시스템의 허용오차인 0.17mm 오차보다는 현저히 작은 값이었고 15mm/s와 30mm/s의 이동 속도에서 모두 비슷한 크기의 오차값을 나타내었다. 4. 개발된 시스템의 속도별 반복정밀도 실험 결과 측정위치에서의 반복에 의한 정지 위치 오차는 전 구간에서 0.02mm 이내로 나타났고, 이동 평판의 이동속도가 15mm/s였을 경우에는 이동 회수 30회, 이동 거리 60mm일 때 최대 편차 0.019mm를 나타냈으며 이동속도가 30mm/s일 경우에는 이동 회수 40회, 이동거리 20mm에서 0.02mm의 최대 편차를 나타내었다. 5. 5개의 알루미늄 조각의 크기를 시스템으로 측정한 결과 측정값의 최대 편차는 0.08mm였다. 이 값은 시스템의 허용오차인 0.17mm의 50% 수준으로 시스템은 대상물의 크기 측정에 적당하다고 사료되었다. 6. 절단된 수삼의 초음파 전달속도는 평균 396.4m/s였다.를 축열재로 사용할 경우 재생기를 반으로 나누어서 가열부 쪽에 철선을, 냉각부 쪽에 철망을 삽입한 것이 반대로 삽입한 것보다 재생기 양단의 온도차는 높게 나타났고, 재생기 양단의 압력 차는 낮게 나타났다. 재생기 축열재로서 철망-철선을 사용할 경우 철선-철망 ø1.2-150이 전열 표면적은 작으나 재생기 양단의 온도차가 가장 큰 것으로 나타났으며 재생기 양단의 압력 차는 가장 낮게 나타나 공시 철망- 철선 혼합 축열재중 가장 우수함을 알 수 있다. 4. 철망사이에 철선을 삽입한 축열재의 경우, 철망사이에 삽입한 철선의 직경이 큰 것이 철선의 직경이 작은 것보다 재생기의 양단의 온도차가 높게 나타났고 재생기 양단의 압력차는 작게 나타났다. 그러므로 철망사이에 철선을 삽입한 것 중 성능이 우수한 것은 150-ø2. 0-150으로 나타났다. 5. 실험한 재생기 축열재들 중에서 성능이 우수한 것들을 비교한 결과, 복합 철선 ø1.2-1 50이 가장 성능이 좋은 것으로 나타났다.적외선.열풍 복합건조방법이 높게 나타나 이것은 곡물 표면에 원적외선 방사에의한 복사열이 전달되어 열장해를 받았기 때문으로 판단되며, 금후 더 연구하여 적정 열풍온도 및 방사체 크기를 구명해야 할 것이다.으로 보여진다 따라서 옻나무 유래 F는 포유동물의 생식기능에 중요하게 작용하는 것으로 사료된다.된다.정량 분석한 결과이다. 시편의 조성은 33.6 at% U, 66.4 at% O의 결과를 얻었다. 산화물 핵연료의 표면 관찰 및 정량 분석 시험시 시편 표면을 전도성 물질로 증착시키지 않고, Silver Paint 에 시편을 접착하는 방법으로도 만족한 시험 결과를 얻을 수 있었다.째, 회복기 중에 일어나는 입자들의 유입은 자기폭풍의 지속시간을 연장시키는 경향을 보이며 큰 자기폭풍일수

  • PDF

Comparative Analysis of Accuracy between Computerized Tomography and Cephalogram for 3-Dimensional Measurement of Maxillofacial Structure (악안면 3차원 계측시 컴퓨터 단층촬영과 두부 방사선 규격사진의 정확성 비교 분석)

  • Paek, Jong-Su;Song, Jae-Chul;Lee, Hee-Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.123-137
    • /
    • 2001
  • Background: The purpose of this study is to evaluate the accuracy of measurements obtained from 3-dimensional computerized tomography and 3-dimensional cephalogram constructed by using the frontal and lateral cephalogram of six human dry skulls. Materials and Methods: After CT scans and each cephalograms were taken, 3-dimensional coordinates (X, Y, Z) of landmarks were obtained using computer programs. In this study, the accuracy of both methods were determined by means of 14 linear measurements compare with caliper measurements. Results: The standard deviation of landmarks of 3-dimensional CT and 3-dimensional cephalogram were 0.23 mm, and 0.30 mm in X axis, 0.27 mm and 0.25 mm in Y axis, and 0.27 mm and 0.31 mm in Z axis. In both methods, the standard deviation were less than 0.5 mm in all landmarks, and the most of landmarks showed less than 1 mm in range. Concerning the accuracy, the mean difference between 3-dimensional CT and manual measurements was 0.33 mm, and 1.13 mm between 3-dimensional cephalogram and manual measurements. The distance between RGo and LGo showed the largest difference (2.03 mm). There were highly significant, and large correlation with manual measurements in both methods (p<0.01). Conclusion: It is concluded that closeness of repeated measures to each skulls reveal the precision of both methods. Computerized tomography and cephalogram for 3-dimensional measurement of maxillofacial structure are equivalent in quality to caliper measurements.

  • PDF

Comparison of Sea Surface Temperature from Oceanic Buoys and Satellite Microwave Measurements in the Western Coastal Region of Korean Peninsula (한반도 서해 연안 해역에서의 해양 부이 관측 수온과 위성 마이크로파 관측 해수면온도의 비교)

  • Kim, Hee-Young;Park, Kyung-Ae
    • Journal of the Korean earth science society
    • /
    • v.39 no.6
    • /
    • pp.555-567
    • /
    • 2018
  • In order to identify the characteristics of sea surface temperature (SST) differences between microwave SST from GCOM-W1/AMSR2 and in-situ measurements in the western coast of Korea, a total of 6,457 collocated matchup data were produced using the in-situ temperature measurements from marine buoy stations (Deokjeokdo, Chilbaldo, and Oeyeondo) from July 2012 to December 2017. The accuracy of satellite microwave SSTs was presented by comparing the ocean buoy data of Deokjeokdo, Chilbaldo, and Oeyeondo stations with the AMSR2 SST data more than five years. The SST differences between the microwave SST and the in-situ temperature measurements showed some dependence on environmental factors, such as wind speed and water temperature. The AMSR2 SSTs were tended to be higher than the in-situ temperature measurements during the daytime when the wind speed was low ($<6ms^{-1}$). On the other hand, they showed positive deviation increasingly as the wind speed increased for nighttime. In addition, increasing tendency of SST differences was related to decreasing sensitivity of microwave sensors at low temperatures and data contamination by land. A monthly analysis of the SST difference showed that unlike the previous trend, which was known to be the largest in winter when strong winds were blowing, the SST difference was largest in summer in Deokjeokdo and Chilbaldo buoy stations. This seemed to be induced by differential tidal mixing at the collocated matchup points. This study presented problems and limitations of the use of microwave SSTs with high contribution to the SST composites in the western coastal region off the Korean peninsula.

Closed-form Localization of a coherently distributed single source with circular array (환형배열에서 닫힌 형식을 이용한 코히어런트 분산 단일음원의 위치 추정 기법)

  • Jung, Tae-Jin;Shin, Kee-Cheol;Park, Gyu-Tae;Cho, Sung-Il
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.6
    • /
    • pp.437-442
    • /
    • 2018
  • In this paper, we propose a method for estimating the position of a source in a closed form when a single source has coherently distributed property against a circular array. When a sound source reaches a sensor through multipath environments, it is seen as a distributed source and can be represented by four variables: the nominal azimuth, nominal elevation, azimuth angular spread, elevation angular spread. Therefore, it requires a lot of computation by a search method such as DSPE (Distributed Source Parameter Estimator). In this paper, we propose a method of estimating the nominal azimuth and elevation angle in a closed form using correlation function and least squares method for fast position estimation. In particular, if the source is assumed as Gaussian distribution model, the standard deviation is also estimated in a closed form. In the simulation, the validity of the proposed method is confirmed by comparing with the DSPE.

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

A Study On RTLS(Real Time Location System) Based on RSS(Received Signal Strength) and RSS Characteristics Analysis with the External Factors (외적요인에 따른 RSS 특성 분석과 이를 이용한 실시간 위치 추적 시스템 구현에 관한 연구)

  • Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.15 no.1
    • /
    • pp.76-85
    • /
    • 2011
  • In this paper, we analysed RSS characteristics by external factors and presented an efficient algorithm for real-time location tracking and its hardware system. The proposed algorithm enhanced the ranging accuracy using Kalman Filter based on the RSS DB. The location tracking system that consists of the tag, AP(Access Point), a data collector(Data Receiver) with IEEE 802.15.4(ZigBee) network environment, and location tracking application that reveal locations of each tag is implemented for the test environment. The location tracking system presented in this paper is implemented with MSP430 microprocessor manufactured by TI(Texas Instrument), CC2420 RF chipset and the location tracking application. With the results of the experiment, the proposed algorithm and the system can achieve the efficiency and the accuracy of location tracking with the average error of 19.12cm, and its standard deviation of 5.31cm in outdoor circumstance. Also, the experimental result shows that exact tracking of position in indoor circumstance cannot achieve because of vulnerable RSS with external circumstance.

Accuracy of Hybrid Navigation System Combining Dead Reckoning and Loran C (추측항법과 Loran C항법을 결합한 Hybrid 항법의 정도)

  • Lee, Won-Woo;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 1984
  • Recently, Hybrid Navigation Systems combining Omega, NNSS, Loran C and Dead reckoning etc. served to give us highly accurate ship's position, and a number of ships are equipped with these navigation systems. In order to evaluate for the accuracy of this navigation system observations of Loran C, 5970 and 9970 chains and Radar at the same time were made on board m.s Jeonbuk 401 and 403 training ships of Gunsan Fisheries Collage at nine stations in the yellow sea from July, 1982 to June, 1983, and then were done by the Hybrid Navigation System combining Dead reckoning and Loran C at the same areas. The authors investigated the accuracy of the Hybrid Navigation System based on measurements of the relative positional error which is defined as the difference between the position fixed by this system or the Loran C system, and the one by the Radar. The obtained results are as follows; 1. The mean standard deviation of the time difference of Loran C were about 0.21$\mu$s in 9970 chain and about 0.06$\mu$s in 5970 chain, and the fluctuation of the time difference of Loran C in 5970 chain was smaller than that in 9970 chain. 2. The positional error between two positions by Radar and the Hybrid Navigation System in 9970 chain was about 0.4 miles, and between two positions by Radar and Loran C was about 0.51 miles. The Hybrid Navigation System was therefore more accurate than Loran C System. 3. The positional error between two positions by Radar and Hybrid Navigation System in 5970 chain was about 0.4 miles, and between two positions by Radar and computer simulation of Loran C was about 0.98 miles. Consequently, Hybrid Navigation System was more accurate than computer simulation of Loran C system.

  • PDF

Preliminary Study on Detection of Marine Heat Waves using Satellite-based Sea Surface Temperature Anomaly in 2017-2018 (인공위성 해수면온도 편차 이용 한반도 연안 해역 고수온 탐지 : 2017-2018년도)

  • Kim, Tae-Ho;Yang, Chan-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.678-686
    • /
    • 2019
  • In this study, marine heat waves on coastal waters of Republic of Korea were detected using satellite-based Sea Surface Temperature Anomaly (SSTA). The detected results were compared with the warm water issues reported by the National Institute of Fisheries Science (NIFS). Marine heat waves detection algorithm using SSTA based on a threshold has proposed. The threshold value was defined as 2℃ for caution and 3℃ for warning issues, respectively. Daily averaged SST data from July to September of 2017-2018 were used to generate SSTA. The satellite-based detection results were classified into nine areas according to the place names used in the NIFS warm water issues. In the comparison of frequency of marine heat waves occurrence to each area with the warm water issue, most areas in the southern coast showed a similar pattern, that is probably NIFS uses spatially well distributed buoys. On the other hand, other sea areas had about two times more satellite detection results. This result seems to be because NIFS only considers the water temperature data measured at limited points. The results of this study are expected to contribute to the development of a satellite-based warm/cold water monitoring system in coastal waters.

Analysis of groundwater level variability in the middle mountain area of Pyoseon watershed in Jeju Island using normalized standard deviation and cross correlation coefficient (정규화된 표준편차 및 교차상관계수를 이용한 제주도 표선유역 중산간지역의 지하수위 변동성 분석)

  • Shin, Mun-Ju;Moon, Soo-Hyoung;Moon, Duk Chul
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.5
    • /
    • pp.337-345
    • /
    • 2020
  • In order to provide information for proper management of groundwater resources, an analysis of the effects of precipitation and groundwater withdrawal on groundwater levels is needed. In this study, we analyzed the correlation of precipitation-groundwater level and groundwater withdrawal-groundwater level using time series data converted by normalized standard deviation (Nor.St.Dev) and cross correlation coefficient (CCC) for nine groundwater monitoring wells in the middle mountainous area in the southeastern Jeju Island. First, the CCCs of precipitation-groundwater level were estimated using daily time series data, and the low CCCs of up to 0.3 were obtained. However, the result of using the Nor.St.Dev showed a clearer correlation by obtaining a CCC of up to 0.8. In addition, in most cases, precipitation variability and groundwater level variability had positive CCCs, whereas groundwater withdrawal variability and groundwater level variability had negative CCCs. Therefore, the groundwater level in this study area was largely influenced by precipitation with little effect of groundwater withdrawal. Lastly, as a result of analyzing the relative effects of Seongpanak and Gyorae rainfall station on the groundwater level, the rainfall at the relatively downstream Gyorae rainfall station has more influence. The analysis method used in this study can be easily used for analyzing the effects of precipitation and groundwater withdrawal on groundwater level variability in other regions in the future.