• Title/Summary/Keyword: 위상 보정

Search Result 322, Processing Time 0.028 seconds

Imaging Fractures by using VSP Data on Geothermal Site (지열지대 VSP 자료를 이용한 파쇄대 영상화 연구)

  • Lee, Sang-Min;Byun, Joong-Moo;Song, Ho-Cheol;Park, Kwon-Gyu;Lee, Tae-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.3
    • /
    • pp.227-233
    • /
    • 2011
  • Attention has been focused on geothermal energy as an alternative energy because it is continuously operable without external supply. Most of geothermal anomalies in Korea are related to deep circulation of groundwater through a fracture system in granite area. Therefore it is very important to understand the distribution of the fracture system which is the main channel of ground water. In this research, we constructed the velocity models with a fracture system and the layered sediments, respectively, and generated synthetic data sets with them to verify the presented vertical seismic profiling (VSP) preprocessing scheme. We compared the results from conventional VSP preprocessing flow to those from VSP preprocessing flow considering fracture system. We noticed that the preprocessing flow considering fracture system retains more sufficient signal including down-going wave than conventional preprocessing. In addition, we applied 3D VSP prestack phase screen migration to the preprocessed reversed VSP (RVSP) data from Seokmo Island so that we were able to image fracture structure of the geothermal site in Seokmo Island.

A CMOS LC VCO with Differential Second Harmonic Output (차동 이차 고조파 출력을 갖는 CMOS LC 전압조정발진기)

  • Kim, Hyun;Shin, Hyun-Chol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.6 s.360
    • /
    • pp.60-68
    • /
    • 2007
  • A technique is presented to extract differential second harmonic output from common source nodes of a cross-coupled P-& N-FET oscillator. Provided the impedances at the common source nodes are optimized and the fundamental swing at the VCO core stays in a proper mode, it is found that the amplitude and phase errors can be kept within $0{\sim}1.6dB$ and $+2.2^{\circ}{\sim}-5.6^{\circ}$, respectively, over all process/temperature/voltage corners. Moreover, an impedance-tuning circuit is proposed to compensate any unexpectedly high errors on the differential signal output. A Prototype 5-GHz VCO with a 2.5-Hz LC resonator is implemented in $0.18-{\mu}m$ CMOS. The error signal between the differential outputs has been measured to be as low as -70 dBm with the aid of the tuning circuit. It implies the push-push outputs are satisfactorily differential with the amplitude and phase errors well less than 0.34 dB and $1^{\circ}$, respectively.

Discrimination of Local Microearthquakes and Artificial Underground Explosions on the Basis of Time-Frequency Domain (시간-주파수 영역에서의 국지 미소지진과 지하인공폭발의 구별)

  • 김소구;박용철
    • The Journal of Engineering Geology
    • /
    • v.7 no.1
    • /
    • pp.63-79
    • /
    • 1997
  • In this study, our purpose is to develop a technique to discriminate artificial explosions from local microearthquakes on the basis of time-frequency domain. To obtain spectral features of artificial explosions and microearthquakes, we used 3-d spectrograms(frequency, time and amplitude) because this is a useful tool to study the frequency content of entire seismic waveforms observed at local and regional distances (e. g., Kim et al., 1994). P and S waves from quarry blasts show that frequency content of dominant amplitude appeared above 10 Hz and Rg phases that are observed at near distance ranges. But P and S waves from microearthquakes have more broad frequency content as well as below 10 Hz. And for discrimination, Pg/Lg spectral ratio is performed below 10 Hz. In order to select time windows we computed group velocity using multiple filter method(MFM) and removed free surface effects from all 3-components data for improving on data quality. Next step, we computed Fast-Fourier transform, and a log average spectral amplitude over seven frequency bands : 0.5 to 3, 2 to 4, 3 to 5, 4 to 6, 5 to 7, 6 to 8 and 8 to 10 Hz. The best separation is observed from 6 to 8 Hz.

  • PDF

Performance Analysis of DS/CDMA with Phase Error Using Hybrid SC/MRC Diversity (위상을 고려한 DS/CDMA 시스템에서 Hybrid SC/MRC 다이버시티 기법을 이용한 성능분석)

  • 김원섭;박진수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.3
    • /
    • pp.355-362
    • /
    • 2003
  • In this paper, we analyzed the DS/CDMA System with Hybrid SC/MRC diversity, as a method to achieve a good performance by reducing the complexity of system, when PLL gain value was revised a phase gulf among branches to make perfect coherent receive signal. The channel is a multipath Nakagami-m fading channel, we consider user(K), processor gain(N), number of paths(Lp) in DS/CDMA system with hybrid SC/MRC diversity. We found that PLL gain values exist to make perfect coherent receive signal. We verified that DS/CDMA system with Hybrid SC/MRC diversity can improve performance when the proper PLL gain values is used in the system. As a result, we verified that the upper limit of PLL gain value is 5dB to make perfect coherent receive signal in the DS/CDMA system with hybrid SC/MRC diversity.

I/Q channel regeneration in 6-port junction based direct receiver (직접 변환 수신기를 위한 Six Port에서의 I와 Q채널의 생성)

  • Kim Seayoung;Kim Nak-Myeong;Kim Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.6 s.324
    • /
    • pp.1-7
    • /
    • 2004
  • The development of direct receiver techniques is expected to be a solution for future wideband or multi-band wireless systems based on software defined radio. In this Paper, we study the regeneration of I and Q signals for the SDR based direct conversion receiver, so that we can handle a wide bandwidth and maintain maximal flexibility in system utilization. After modeling the basic system considering the real wireless communication environment, and studying the impact of imperfect phase imbalance on the performance of a direct conversion receiver, we propose a suboptimal I and Q signal regeneration algorithm for the system. The proposed algerian regenerates I and Q signals using a real time early-late compensator which effectively estimates phase imbalances and gives feedback in a directreceiver. The proposed algorithm is shown to mitigate the impact of AWGN and improves performance especially at low SNR channel condition. According to the computer simulation, the BER performance of the proposed system is at least about 4 dB better than conventional systems under $45{\~}55$ degrees random phase errors.

Matching Points Extraction Between Optical and TIR Images by Using SURF and Local Phase Correlation (SURF와 지역적 위상 상관도를 활용한 광학 및 열적외선 영상 간 정합쌍 추출)

  • Han, You Kyung;Choi, Jae Wan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.1
    • /
    • pp.81-88
    • /
    • 2015
  • Various satellite sensors having ranges of the visible, infrared, and thermal wavelengths have been launched due to the improvement of hardware technologies of satellite sensors development. According to the development of satellite sensors with various wavelength ranges, the fusion and integration of multisensor images are proceeded. Image matching process is an essential step for the application of multisensor images. Some algorithms, such as SIFT and SURF, have been proposed to co-register satellite images. However, when the existing algorithms are applied to extract matching points between optical and thermal images, high accuracy of co-registration might not be guaranteed because these images have difference spectral and spatial characteristics. In this paper, location of control points in a reference image is extracted by SURF, and then, location of their corresponding pairs is estimated from the correlation of the local similarity. In the case of local similarity, phase correlation method, which is based on fourier transformation, is applied. In the experiments by simulated, Landsat-8, and ASTER datasets, the proposed algorithm could extract reliable matching points compared to the existing SURF-based method.

Effect of annular phase apodizer on the read-out signal in an optical disc system (환형 위상변조 Apodizer가 광학디스크 시스템의 재생신호에 미치는 영향)

  • jeong, Ho;Chung, Chang-Sub;Park, Seong-Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.270-275
    • /
    • 2001
  • We have studied effects of annular phase apodizer and bump shapes on the read-out signal in an optical disc system, using scalar diffraction theory. In order to detennine the optimum parameters of annular phase apodizer which will minimize the influence of spherical aberration, we defined WR as the ratio between the maximum wavefront aberration and some absolute value of wavefront aberration at any position r in the pupil. A cylindric bump, a semi-conic bump and a conic bump were$.$ also considered as different types of bump shape. As the radius and shape of bump varies, the read-out signal from an optical disc system with an annular phase apodizer was similar to that from an optical disc system without apodizer. When spherical aberration increases, the maximum read-out signal of an optical disc system with an annular phase apodizer and minimum bump radii giving read-out signal higher than 0.6 rarely varied. Especially, the optimum parameters at $W_R$ = 0.4 , 0.6 gave the most compensated effect of a spherical aberration.ration.

  • PDF

Precise Measurement of Ultra Small Retardation of Rubbed Polyimide Alignment Layer Using an Improved Transmission Ellipsometer (개선된 투과형 타원계를 사용한 러빙된 Polyimide 배향막의 초미세 위상지연 정밀 측정)

  • Lyum, Kyoung Hun;Park, Sang Uk;Yang, Seong Mo;Yoon, Hee Kyu;Kim, Sang Youl
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.77-85
    • /
    • 2013
  • The precision of retardation measurement has been improved upto $3{\sigma}$ <0.005 nm after improvements are made to the conventional transmission ellipsometer. Improvements are made such that, i) the polarizer module instead of the sample stage is rotated, ii) the light source is replaced, iii) the starting points of two rotating modules are accurately synchronized, and iv) the fine background retardation is compensated. Together with the newly introduced RVD (Retardation Vector Difference) method, the improved instrument is successfully applied to characterize the ultra small optical birefringence of the rubbed polyimide alignment layer, after the residual retardation due to glass substrate whose magnitude is about 1.0 nm is properly subtracted. It is verified that the net retardation of the alignment layer ranges from 0.05 nm to 0.15 nm.

Design of Sub-array Receiver for Active Phase Array Radar (능동위상배열 레이더 부배열 수신기 설계)

  • Yi, Hui-min;Kim, Do-hoon;Han, Il-tak
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.5
    • /
    • pp.568-573
    • /
    • 2019
  • Modern Radars are evolving into MFRs which can search multiple targets simultaneously and then track them. Additionally they should be able to avoid some external jamming signals. Applying to these MFRs, Antennas should be able to perform DBF including to not only real-time beam steering but also multi-beam forming simultaneously. And they can cancel the beam at the specific direction. In this paper, we describe the implementation of sub-array type antenna hardware which can be applying DBF. Also we propose the modified amplitude aperture distribution for suppressing the side lobe level and explain the sub-array receiver design with amplitude tapering. It consists in making the amplitude weighting in 2 steps. In order to compare two weighting cases, we investigate the G/T performance for the array antenna. At the conclusion, we make a comparative study for the dynamic range of every sub-array receiver and present the hardware implementation that is more advantageous for sub-array alignment and calibration in DBF.

Design of Phase Locked Loop (PLL) based Time to Digital Converter for LiDAR System with Measurement of Absolute Time Difference (LiDAR 시스템용 절대시간 측정을 위한 위상고정루프 기반 시간 디지털 변환기 설계)

  • Yoo, Sang-Sun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.5
    • /
    • pp.677-684
    • /
    • 2021
  • This paper presents a time-to-digital converter for measuring absolute time differences. The time-to-digital converter was designed and fabricated in 0.18-um CMOS technology and it can be applied to Light Detection and Ranging system which requires long time-cover range and 50ps time resolution. Since designed time-to-digital converter adopted the reference clock of 625MHz generated by phase locked loop, it could have absolute time resolution of 50ps after automatic calibration and its cover range was over than 800ns. The time-to-digital converter adopted a counter and chain delay lines for time measurement. The counter is used for coarse time measurement and chain delay lines are used for fine time measurement. From many times experiments, fabricated time-to-digital converter has 50 ps time resolution with maximum INL of 0.8 LSB and its power consumption is about 70 mW.