• Title/Summary/Keyword: 위상대조도

Search Result 57, Processing Time 0.031 seconds

Development and Feasibility Study for Phase Contrast MR Angiography at Low Tesla Open-MRI System (저자장 자기공명영상 시스템에서의 위상대조도 혈관조영기법의 개발과 그 유용성에 대한 연구)

  • Lee, Dong-Hoon;Hong, Cheol-Pyo;Lee, Man-Woo;Han, Bong-Soo
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.177-187
    • /
    • 2012
  • Magnetic resonance angiography (MRA) techniques are widely used in diagnosis of vascular disorders such as hemadostenosis and aneurism. Especially, phase contrast (PC) MRA technique, which is a typical non contrast-enhanced MRA technique, provides not only the anatomy of blood vessels but also flow velocity. In this study, we developed the 2- and 3-dimensional PC MRA pulse sequences for a low magnetic field MRI system. Vessel images were acquired using 2D and 3D PC MRA and the velocities of the blood flow were measured in the superior sagittal sinus, straight sinus and the confluence of the two. The 2D PC MRA provided the good quality of vascular images for large vessels but the poor quality for small ones. Although 3D PC MRA gave more improved visualization of small vessels than 2D PC MRA, the image quality was not enough to be used for diagnosis of the small vessels due to the low SNR and field homogeneity of the low field MRI system. The measured blood velocities were $25.46{\pm}0.73cm/sec$, $24.02{\pm}0.34cm/sec$ and $26.15{\pm}1.50cm/sec$ in the superior sagittal sinus, straight sinus and the confluence of the two, respectively, which showed good agreement with the previous experimental values. Thus, the developed PC MRA technique for low field MRI system is expected to provide the useful velocity information to diagnose the large brain vessels.

A Study on measurement blood velocity according to variable changing in magnetic resonance phase contrast image (자기공명 위상대조도 기법에서 병렬영상기법 변화에 따른 혈류정량 측정에 관한 연구)

  • Cho, yong-bum;Yang, seon-wook;Son, soon-yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2017.05a
    • /
    • pp.107-108
    • /
    • 2017
  • 3차원 위상대조도 기법의 단점인 긴 검사시간으로 인해 임상적 유용성이 떨어진다. 본 논문은 시간매개변수인 병렬영상기법(Grappa) 변경에 따른 혈류정보의 정량적 평가를 통해 차이점을 알아보고 임상적 활용정도를 평가하였다. 자체 제작한 혈류팬텀을 통해 실험하였으며, Grappa을 5번 변경하여 실험하였다. 연구결과, Grappa를 적용하지 않았을 경우 혈류속도는 평균 9.42로 총 4단계를 적용한 혈류속도 차이율은 각각(1.4, 1.5, 0.4, 1.5%)이었으며 flow와 WSS도 각각(1.4, 1.6, 0.8, 25%), (2.1, 1.4, 1.1, 0.8%)이었다. 통계적으로도 유의하지 않아 Grappa를 적용하지 않은 검사법과 혈류정보가 동일하였다.(P>0.05) 긴 검사 시간으로 인해 임상적 활용이 떨어지는 짧은 검사시간을 요하는 소아환자나 중등도 환자 또는 폐쇄공포증 환자에게 시간을 단축한 3차원 위상대조도 기법을 사용하여 단점을 보완한다면 임상적 활용가치가 높아질 것이라 사료된다.

  • PDF

3D Histology Using the Synchrotron Radiation Propagation Phase Contrast Cryo-microCT (방사광 전파위상대조 동결미세단층촬영법을 활용한 3차원 조직학)

  • Kim, Ju-Heon;Han, Sung-Mi;Song, Hyun-Ouk;Seo, Youn-Kyung;Moon, Young-Suk;Kim, Hong-Tae
    • Anatomy & Biological Anthropology
    • /
    • v.31 no.4
    • /
    • pp.133-142
    • /
    • 2018
  • 3D histology is a imaging system for the 3D structural information of cells or tissues. The synchrotron radiation propagation phase contrast micro-CT has been used in 3D imaging methods. However, the simple phase contrast micro-CT did not give sufficient micro-structural information when the specimen contains soft elements, as is the case with many biomedical tissue samples. The purpose of this study is to develop a new technique to enhance the phase contrast effect for soft tissue imaging. Experiments were performed at the imaging beam lines of Pohang Accelerator Laboratory (PAL). The biomedical tissue samples under frozen state was mounted on a computer-controlled precision stage and rotated in $0.18^{\circ}$ increments through $180^{\circ}$. An X-ray shadow of a specimen was converted into a visual image on the surface of a CdWO4 scintillator that was magnified using a microscopic objective lens(X5 or X20) before being captured with a digital CCD camera. 3-dimensional volume images of the specimen were obtained by applying a filtered back-projection algorithm to the projection images using a software package OCTOPUS. Surface reconstruction and volume segmentation and rendering were performed were performed using Amira software. In this study, We found that synchrotron phase contrast imaging of frozen tissue samples has higher contrast power for soft tissue than that of non-frozen samples. In conclusion, synchrotron radiation propagation phase contrast cryo-microCT imaging offers a promising tool for non-destructive high resolution 3D histology.

Phase Dependent Image Contrast Enhancement in MRI

  • Y.M Ro;C. W. Mun;I. K. Hong
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.165-172
    • /
    • 1999
  • An enhancement technique for phase dependent image contrast in MRI(Manetic Resonance Imaging) is proposed. Because the method can enhance inherent phase contrast it is suited for susceptibility imaging and flow imaging where intravoxel phase is a source of image contrast. In this paper, applying external phase in the voxel enhances phase contrast. The external phase is generated by a tailored RF pulse so that one can control the phase contrast and even produces phase only contrast. Signal intensity due to both inherent phase and external phase is analyzed and the proposed technique is applied to a susceptibility effect only imaging and a flow effect only imaging. To verify the proposed technique, computer simulations are performed and their results are given.

  • PDF

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.

Blood Flow Measurement with Phase Contrast MRI According to Flip Angle in the Ascending Aorta (위상대조도 MRI에서 숙임각에 따른 상행대동맥의 혈류 측정)

  • Kim, Moon Sun;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.142-148
    • /
    • 2016
  • To evaluate the effect of flip angle on flow rate measurements obtained with phase contrast MRI according to the flip angle degree in ascending aorta and velocity encoding (VENC) was (150 m/s). 1.5T MRI in patients 17 (female: 8, male: 9, mean age $57.9{\pm}15.4$) as a target by applying a non-breath holding techniques to flip angle VENC (150 cm/s) in each of the ascending aorta was measured by changing $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$. Blood was obtained a peak velocity, average velocity, net forward volume, net forward volume/body surface area. Ascending aorta from average velocity (AV) measured the average value of the flip angle $20^{\circ}$ (9.87 cm/s), $30^{\circ}$ (9.6 cm/s) and $40^{\circ}$ (10.05 cm/s). Blood flow VENC in was blood flow change in flip angle change was high most blood flow measurement when the flip angle $30^{\circ}$ in VENC, crouching each blood flow is also proportional to the increases in the $20^{\circ}$ to $40^{\circ}$ and was increased, the deviation of the peak velocity and the average velocity is the smallest deviation from the flip angle $30^{\circ}$. Flip angle $20^{\circ}$, $30^{\circ}$ and $40^{\circ}$ in peak velocity, average velocity, net forward volume, net forward volume/body surface area was no statistically significant difference (p > .05). Blood flow velocity and blood flow is measured by applying to adjust the flip angle accurately calculate the blood flow is important information for diagnosis and treatment of cardiovascular diseases, and can help in the examination on the blood flow measurement.

Changes in Total Cerebral Blood Flow with Aging, Parenchymal Volume Changes, and Vascular Abnormalities: a Two-dimensional Phase-Contrast MRI Study (나이와 뇌실질부피 변화 및 혈관이상에 따른 총뇌혈류량 변화: 이차원 위상대조 자기공명영상을 이용한 연구)

  • Liu Haiying;Shin Tae-Beom;Youn Seong-Kuk;Oh Jong-Yong;Lee Young-Il;Choi Sun-Seob
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.17-23
    • /
    • 2004
  • Purpose : To evaluate changes in total cerebral blood flow (tCBF) with aging, parenchymal volume changes and vascular abnormalities, using 2 dimensional (D) phase-contrast magnetic resonance imaging (PC MRI). Materials and Methods : Routine brain MRI including T2 weighted image, time-of-flight (TOF) MR Angiography (MRA) and 2D PC MRI were performed in 73 individuals, including 12 volunteers. Normal subjects (12 volunteers, and 21 individuals with normal MRI and normal MRA) were classified into groups according to age (18-29, 30-49 and 50-66 years). For the group with abnormalities in brain MRIs, cerebral parenchymal volume changes were scored according to the T2 weighted images, and atherosclerotic changes were scored according to the MRA findings. Abnormal groups were classified into 4 groups: (i) mild reduction in volume, (ii) marked reduction in volume by parenchymal volume and atherosclerotic changes, and (iii) increased volume and (iv) Moya-moya disease. Volumetric flow was measured at the internal carotid artery (ICA) and vertebral artery bilaterally using the velocity-flow diagrams from PC MRI, and combined 4 vessel flows and tCBF were compared among all the groups. Results : The age-specific distribution of tCBFs in normal subjects were as follows: $12.0{\pm}2.1ml/sec$ in 18-29 years group, $11.8{\pm}1.9ml/sec$ in 30-49 years group, $10.9{\pm}2.2ml/sec$ in 50-66 years group. The distribution of tCBFs in the different subsets of the abnormal population were as follows: $9.5{\pm}2.5ml/sec$ in the group with mild reduction in volume, $7.6{\pm}2.0ml/sec$ in the group with marked reduction in volume, and $7.3{\pm}1.2ml/sec$ and $7.0{\pm}1.1ml/sec$ in the increased parenchymal volume and Moya-moya disease groups respectively. Conclusion : Total cerebral blood flow decreases with increasing age with a concomitant reduction in parenchymal volumes and increasing atherosclerotic changes. It is also reduced in the presence of increased parenchymal volume and Moya-moya disease.2D PC MRI can be used as a tool to evaluate tCBF with aging and in the presence of various conditions that can affect parenchymal volume and cerebral vasculature.

  • PDF

The Assessment of the Breath Hold and the Free Breath Methods about the Blood Flow Evaluation by Using Phase Contrast MRI (위상대조도 자기공명영상을 이용한 심장 혈류평가에 있어서 호흡정지 기법과 비 호흡정지 기법의 비교평가)

  • Kim, Seong-Ho
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.149-156
    • /
    • 2016
  • Measurement of cardiac blood flow using the magnetic resonance imaging has been limited due to breathing and involuntary movements of the heart. The present study attempted to improve the accuracy of cardiac blood flow testing through phase contrast magnetic resonance imaging by presenting the adequate breathing method and imaging variables by comparing the measurement values of cardiac blood flow. Each was evaluated by comparing the breath hold retrospective 1NEX and non breath hold retrospective 1-3NEX in the ascending aorta and descending aorta. As a result, the average blood flow amount/velocity of the breath hold retrosepctive 1NEX method in the ascending aorta were $96.17{\pm}19.12ml/sec$, $17.04{\pm}4.12cm/sec$ respectively, which demonstrates a statistically significant difference(p<0.05) with the non-breath hold retrospective method 1NEX of $72.31{\pm}13.27ml$ and $12.32{\pm}3.85$. On the other hand, the average 2NEX blood flow and mean flow velocity is $101.90{\pm}24.09$, $16.84{\pm}4.32$, 3NEX $103.06{\pm}25.49$, $16.88{\pm}4.19$ did not show statistically significant differences(p>0.05).The average blood flow amount/ velocity of the breath hold retrospective 1NEX method in the descending aorta were $76.68{\pm}19.72ml/s$, and $22.23{\pm}4.8$, which did not demonstrate a significant difference in comparison to non-breath hold retrospective method 1-3 NEX. Therefore, the non breath hold retrospective method does not significantly differ in terms of cardiac blood flow in comparison with the breath hold retrospective method in accordance with the increase of NEX, so pediatric patients or patients who are not able to breathe well must have the diagnostic value of their cardiac blood flow tests improved.

NDE of the Internal Hole Defect of Dental Composite Restoration Using Infrared Lock-In Thermography (위상잠금 열화상기법을 이용한 치과용 복합레진 수복재의 내부 홀 결함에 대한 비파괴평가)

  • Gu, Ja-Uk;Choi, Nak-Sam
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.40-45
    • /
    • 2013
  • The purpose of this study was to detect the pin hole defect of dental composite restoration using lock-in thermography method. Amplitude and phase images of the composite resin specimens were analyzed according to the lock-in frequency and the diameter of defect area. Through the amplitude image analysis, at lock-in frequency of 0.05 Hz, defect diameters 2-5 mm exhibited the highest amplitude contrast value between defective area and sound area. The lock-in frequency range of 0.3-0.5 Hz provided good phase angle contrast for the defect area. At lock-in frequency range of 0.5 Hz, defect diameter of 5 mm exhibited the highest phase contrast value. It is concluded that the infrared lock-in thermography method verified the effectiveness for detecting the pin hole defect of dental composite restoration.

The Variation of Tagging Contrast-to-Noise Radio (CNR) of SPAMM Image by Modulation of Tagline Spacing (Tagline 간격의 조절을 통한 SPAMM 영상에서의 Tagging 대조도 대 잡음비의 변화)

  • 강원석;최병욱;최규옥;이상호;홍순일;정해조;김희중
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.224-228
    • /
    • 2002
  • Myocardial tagging technique such as spatial modulation of magnetization (SPAMM) allows the study of myocardial motion with high accuracy. However, the accuracy of the estimation of tag intersection can be affected by tagline spacing. The aim of this study was to investigate the relationship between tagline spacing of SPAMM image and tagging contrast-to-noise ratio (CNR) in in-vivo study. Two healthy volunteers were undergone electrocardiographically triggered MR imaging with SPAMM-based tagging pulse sequence at a 1.5T MR scanner. Horizontally modulated stripe patterns were imposed with a range from 3.6 to 9.6 mm of tagline spacing. Images of the left ventricle(LV) wall were acquired at the mid-ventricle level during cardiac cycle with FE-EPI (TR/TE = 5.8/2.2 msec, FA= 10$^{\circ}$. Tagging CNR for each image was calculated with a software which developed in our group. During contraction, tagging CNR was more rapidly decreased in case of narrow tagline spacing than in case of wide tagline spacing. In the same heart phase, CNR was increased corresponding with tagline spacing. Especially, at the fully contracted heart phase, CNR was more rapidly increased than the other heart phases as a function of tagline spacing. The results indicated that the optimization of tagline spacing provides better tagging CNR in order to analyze the myocardial motion more accurately.

  • PDF