• Title/Summary/Keyword: 원판

Search Result 657, Processing Time 0.036 seconds

Discoid Medial Meniscus Rupture - Case report - (원판형 내측 연골판 파열 - 1 예 보고 -)

  • Kim, Dong-Hui;Kim, Bae-Gyun;Kim, Jung-Man
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.1
    • /
    • pp.51-53
    • /
    • 2004
  • Although the lateral discoid meniscus of the knee has been observed frequently, the discoid medial meniscus has rarely been reported in the literature. A discoid medial meniscus with the horizontal tear and the peripheral tear of upper lip were observed. This tear pattern is not usual in the lateral discoid meniscus as well as in the normal meniscus. A plausible mechanism of the tear pattern compared with the normal shape and the discoid lateral meniscus was discussed in the following.

  • PDF

Assisting High School Students to Redefine the Principle of Coriolis Force (전향력 발생 원리를 고등학생들에게 설명하기 위한 새로운 방법)

  • Jang, Swung-Hwan;Park, Hyo-Jin;Cho, Kyu-Seong;Moon, Byung-Kwon
    • Journal of the Korean earth science society
    • /
    • v.32 no.1
    • /
    • pp.73-83
    • /
    • 2011
  • A new method was developed to better understand the principle of Coriolis force. We also investigated the understanding of 5 10th grade students and analyzed their responses. Since no clear explanation about the nature of a rotating disk is provided in school textbooks, it tends to be misunderstood as the earth surface revolving on its axis pointing to the North Pole. This study was carried out focusing on the fact that a rotating disk is the tangential plane at arbitrary latitude. Results showed that there are changes in students' conceptions on the principle of Coriolis force with a new understanding of the rotating disk. In conclusion, a new method used in this study helped students better understand the link between Coriolis force and rotating disk. The method would be helpful to clarify the principle of Coriolis force in school science.

Closed-form Expressions of Magnetic Field and Magnetic Gradient Tensor due to a Circular Disk (원판형 이상체에 의한 자력 및 자력 변화율 텐서 반응식)

  • Rim, Hyoungrea
    • Geophysics and Geophysical Exploration
    • /
    • v.25 no.1
    • /
    • pp.38-43
    • /
    • 2022
  • In case axial symmetrical bodies with varying cross sections such as volcanic conduits and unexploded ordnance (UXO), it is efficient to approximate them by adding the response of thin disks perpendicular to the axis of symmetry. To compute the vector magnetic and magnetic gradient tensor respones by such bodies, it is necessary to derive an analytical expression of the circular disk. Therefore, in this study, we drive closed-form expressions of the vector magnetic and magnetic gradient tensor due to a circular disk. First, the vector magnetic field is obtained from the existing gravity gradient tensor using Poisson's relation where the gravity gradient tensor due to the same disk with a constant density can be transformed into a magnetic field. Then, the magnetic gradient tensor is derived by differentiating the vector magnetic field with respect to the cylindrical coordinates converted from the Cartesian coordinate system. Finally, both the vector magnetic and magnetic gradient tensors are derived using Lipschitz-Hankel type integrals based on the axial symmetry of the circular disk.

Effects of Transverse Shear Deformation and Rotary Inertia on Vibration of Rotating Polar Orthotropic Disks (극직교 이방성 회전원판의 진동에 대한 횡전단변형 및 회전관성 효과)

  • Kim, Dong-Hyun;Koo, Kyo-Nam
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.43-49
    • /
    • 2007
  • Dynamic instability of rotating disks is the most significant factor to limit its rotating speed. Application of composite materials to rotating disks may enhance the dynamic stability leading to a possible design of rotating disks with lightweight and high speed. Whereas much work has been done on the effect of transverse shear and rotary inertia, called Timoshenko effect, on the dynamic behavior of plates, there is little work on the correlation between the effect and the rotation of disk, especially nothing in case of composite disks. The dynamic equations of a rotating composite disk are formulated with the Timoshenko effect and the vibrational analysis is performed by using a commercial package MSC/NASTRAN. According to the results, the Timoshenko effect goes seesaw in some modes, unlike the well-known fact that the effect decreases as the rotating speed increases. And it can be concluded, based only on the present results, that decrement of the Timoshenko effect by disk rotation grows larger as the thickness ratio decreases, the diameter ratio increases, the modulus ratio increases, and the mode number increases.

Opening Exercise Therapy with Locking-free Appliance(LA) : Preliminary Study (Locking-free Appliance(LA)를 이용한 개구운동치료 : 예비실험)

  • Jung, Won;Lee, Kyung-Eun;Sun, Sae-Ah;Suh, Bong-Jik
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.1
    • /
    • pp.29-34
    • /
    • 2013
  • Objective: All patients who have the disc displacement with reduction (DDwR) are always not progressive but some of them with significant catching or locking progress to disc displacement without reduction (DDw/oR). In this study, we suggest opening exercise therapy using Locking-free Appliance (LA) to be helpful to prevent progressive derangement. Methods: Retrospectively, a total 37 patients who received exercise treatment using LA was analyzed from January 2010 to December 2011. Patients had been instructed in proper exercise technique to practise for opening and closing of mouth wearing the appliance 30 times a day in locking-free position. Results: None of the patients took a turn for worse to DDw/oR (37 patients). The 16 patients (43.2%, locking-free group) of them could open their mouth without intermittent condylar locking. Measurement of data was analyzed using and Mann-Whitney test. There was no statistically significant difference for age, gender, presence of palpational pain, locking period, VAS quantitative pain score between locking-free group and locking group. Conclusions: In this study, some patients could open their mouth without intermittent locking and did not take a turn for worse to DDw/oR after opening exercise therapy with LA. Furthermore, LA had advantages which were short wearing time, low costs and minimizing patients' uncomfortable compared to conventional treatment method. This therapy can be more appropriate new treatment to prevent progress to DDw/oR.

Ammonia removal rate on ammonia loading rates in seawater filtering system using rotating biological contactor (RBC) (회전원판을 이용한 해수 순환여과 시스템에서 암모니아 부하율에 따른 암모니아 제거율)

  • SON Maeng Hyun;JEON Im Gi;CHO Kee Chae;KIM Kang Soo
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.33 no.4
    • /
    • pp.367-372
    • /
    • 2000
  • A series of experiment was conducted to investigate the relationship between ammoia removal rate and ammonia loading rates in seawater filtering system using rotating biological contactor (RBC). In this experiment, RBC system was consisted of rotating polyvinyl film disks, which provided $12 m^2$ of total effective surface area in $0.075 m^3$ of volume. $NH_4Cl$ was added by $10{\~}150 g$ as a ammonia nitrogen source to determine ammonia removal rate in RBC system. Relationship between time required for ammonia removal (y: hour) and nitrogen inputted ($x: NH_4-N mg/l$) in RBC system was as followed: $y=3.51+7.76 lnx (r^2=0.936)$. At ammonia concentration $2 mg/l$, it took 10 hour for removal of ammonia in the RBC system. However, at ammonia concentration of $5 and 16.5 mg/l$, it took 16 and 27 hours, respectively. There was a decreasing tencency of an increasing ammonia in the rearing water. Finally, the ammonia removal rate in the RBC system increased with the rise of total ammonia concentration up to $16.5 mg/l$.

  • PDF

Simultaneous Medial and Lateral Discoid Meniscus in one Knee joint (한쪽 슬관절에서 내측 및 외측에 동시에 발생한 원판형 연골 - 1예 보고 -)

  • Cho, Young-Ho;An, Hyug-Su;Chang, Se-Ang;Nam, Seung-Oh
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.95-98
    • /
    • 2006
  • Most of discoid menisci are lateral and medial discoid meniscus is very rare. There is no report about simultaneous medial and lateral discoid meniscus in one knee joint. A 15-year-old male patient was diagnosed as having a complete medial discoid meniscus with horizontal tear and intact incomplete lateral discoid meniscus by means of magnetic resonance image and arthroscopy. The patient was treated by arthroscopic partial meniscectomy for both discoid menisci.

  • PDF

Discoid Medial Meniscus in the Knee - A case report - (슬관절 내측 원판형 연골 - 1례 보고 -)

  • Kyung, Hee-Soo;Kim, Kyung-Hoon;Oh, Chang-Wug
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.58-62
    • /
    • 2009
  • A discoid medial meniscus is a relatively rare pathology of the knee joint, and we recently encountered a patient with discoid medial meniscus, and this report is a case of therapeutic experience in this patient. The patient was twenty years old man who had a persistent dull pain for several years without specific trauma history. He was presumptively diagnosed as discoid medial meniscus by MRI, and arthroscopic examination confirmed the presence of the complete type of discoid medial meniscus with horizontal tear. We performed arthroscopic partial meniscectomy, and the patient could get free from symptom.

  • PDF

An Experimental Study on the Pumping Performance of the Multi-stage Disk-type Drag Pump (다단 원판형 드래그펌프의 배기 성능에 관한 실험적 연구)

  • 권명근;허중식;황영규
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.2
    • /
    • pp.79-85
    • /
    • 2003
  • Experimental investigations are performed for the rarefied gas flows in a multi-stage disk-type drag pump. The pump considered in the present study consists of grooved rotors and stators. The flow-meter method is adopted to calculate the pumping speed. Compression ratios and pumping speeds for the nitrogen gas are measured under the outlet pressure range of 0.13∼533 Pa. The present experimental data show the leak-limited value of the compression ratio in the molecular transition region. The rotational speed of the pump is 24,000rpm, and nitrogen is used as a test gas. The pumping characteristics of various drag pumps are performed. The inlet pressures are measured for various outlet pressures of the test pump. The ultimate pressures for zero throughput are measured for three-stage, two-stage and single-stage disk-type, respectively.

Filamentous Bacteria Found in Rotating Biological Contactors Treating Domestic Wastewater (생활하수를 처리하는 회전원판체에서 발견된 사상세균)

  • 정재춘
    • Korean Journal of Microbiology
    • /
    • v.28 no.4
    • /
    • pp.337-344
    • /
    • 1990
  • Slime sampless from 10 ratating biological contactor (RBC) plants in New Jersey were microscopically examined. Filamentous bacteria such as Type 1701, Type 0041, Type 021N, Nocardia, Beggiatoa, and Sphaerotilus, which are commonly present as suspended forms also were found in RBC slimes growing as attached forms. However, the abundance wwas much different from that of activated sludge. In RBC slimes, Beggiatoa was most frequently observed filamentous bacteria and Sphaerotilus, Type 0041, Type 1701, Type 021N and Nocardia were present in decreasing order of abundance. There were morphologically two different types of Behhiatia in RBC slimes. The statistical anaysis shows that filamentous bacterial poulations between the 100 cm inside and the outside the RBC were different in most cases with significant interactions between the location and stage.

  • PDF